I-ADAPTER STRAND PACKAGE

ngodayi obomvu u-Ra
I-Dynamic Biosensors GmbH & Inc.
I-ASP-1-Ra v5.1

BIOSENSORS ASP 1 Ra Adapter Strand Package - ikhava

Izici Eziyinhloko

  • I-Adapter strand 1 – Ra ne-Adapter strand 2 – Ra – lfs (ligand free strand) ukuze isebenze i-heliX® Adapter Chip ku-Spot 1 kanye ne-Spot 2, ngokulandelana.
  • Ihambisana ne-heliX® Adapter Chip.
  • Kufaka phakathi imicu ye-Adapter yokwenziwa kabusha okungu-50.
  • Ilungele i-MIX&RUN sample ukulungiselela.
  • Imicu ye-adaptha 1 kanye no-2 iphethe udayi obomvu we-hydrophilic (Ra) ene-net charge eyodwa.

I-heliX® Adapter Chip Overview

Izindawo ezi-2 ezinokulandelana kwesikhonkwane oku-2 okuhlukile kwekheli elinekhodi ye-DNA.

I-BIOSENSORS ASP 1 ye-Ra Adapter Strand Package - I-Adapter Chip Overview 1

Incazelo Yomkhiqizo

Inombolo ye-oda: ASP-1-Ra
Ithebula 1. Okuqukethwe kanye Nokwaziswa Kwesitoreji

Okubalulekile Cap Ukugxila  Inani Ibhafa Isitoreji
I-adaptha umucu 1 – Ra Mnyama 400 nM 5 x 100µL I-TE40 [1] -20°C
I-adaptha umucu 2 – Ra – lfs Emhlophe 200/250 nM 5 x 200µL I-TE40 [1] -20°C

Okokusetshenziswa kocwaningo kuphela.
Lo mkhiqizo unomkhawulo wempilo yeshelufu, sicela ubone idethi yokuphelelwa yisikhathi kulebula.
Ukuze ugweme imijikelezo eminingi yokuncibilika kweqhwa sicela uliquot i-nanolever.

Ukulungiselela | MIX&RUN

I-in-solution hybridization ye-adaptha nemicu ye-ligand:

  1. Hlanganisa umucu we-Adaptha 1 – Ra (400 nM) kanye ne-conjugated Ligand strand (500 nM) ngesilinganiso esingu-1:1 (v/v).
  2. Faka isixazululo sesinyathelo 1 ku-RT ku-600 rpm imizuzu engama-30 ukuze uqinisekise ukuhlanganisa okuphelele.
  3. Hlanganisa isisombululo sesinyathelo sesi-2 ne-Adapter strand 2 – Ra – lfs (200 nM) ngesilinganiso esingu-1:1 (v/v). Isixazululo sesilungele ukusetshenziswa ekusebenzeni kwe-biochip.
    Ukuzinza kwesixazululo kuhlobene nokuzinza kwe-molecule ye-ligand.

I-BIOSENSORS ASP 1 ye-Radapter Strand Package - Ukulungiselela 1

Ithebula 2. Izinto ezengeziwe zokusebenzisa indawo 1 nendawo eyinkomba 2.

Okubalulekile Ukugxila  Ibhafa  Igama Lomkhiqizo Ohlobene I-oda No
I-Ligand strand ethwele i-conjugated ligand 500 nM I-PE40 [2] I-heliX® Amine Coupling Kit 1 I-HK-NHS-1

Example

Ivolumu edingekayo yokusebenza oku-3: 100 µL nokugxiliswa kokugcina okungu-100 nM.

I-Vial 1 I-Vial 2
I-adaptha umucu 1 – Ra (400 nM) I-Ligand strand ehlanganisiwe (500 nM) I-adaptha umucu 2 – Ra – lfs (200/250 nM)
25µL 25µL 50µL

Ngemva kwesikhathi sokufukamela, hlanganisa ibhodlela 1 kanye nebhodlela 2 ukuze uthole u-100 µL wesixazululo se-DNA esilungele ukusetshenziswa.

Oxhumana naye

I-Dynamic Biosensors GmbH
I-Perchtinger Str. 8/10
81379 eMunich
EJalimane
Inkampani engu-Dynamic Biosensors, Inc.
300 Trade Center, Suite 1400
I-Woburn, i-MA 01801
USA

Oda Ulwazi order@dynamic-biosensors.com
Ukusekela kwezobuchwepheshe support@dynamic-biosensors.com

www.dynamic-biosensors.com

Izinsimbi nama-chips akhiwe futhi akhiqizwa eJalimane.
©2024 Dynamic Biosensors GmbH | Dynamic Biosensors, Inc. Wonke amalungelo agodliwe.

[1] TE40: 10 mM Tris, 40 mM NaCl, 0.05 % Tween20, 50 μM EDTA, 50 μM EGTA
[2] Uma iphrotheni ingazinzile ku-PE40 (TE40, HE40),
sicela uhlole ukuhambisana kwebhafa neshidi lokuhambisana le-switchSENSE®.
I-ASP-1-Ra v5.1
www.dynamic-biosensors.com

Amadokhumenti / Izinsiza

i-BIOSENSORS ASP-1-Ra Adapter Strand Package [pdf] Imaniwali yosebenzisayo
ASP-1-Ra, ASP-1-Ra v5.1, ASP-1-Ra Adapter Strand Package, ASP-1-Ra, Adapter Strand Package, Strand Package

Izithenjwa

Shiya amazwana

Ikheli lakho le-imeyili ngeke lishicilelwe. Izinkambu ezidingekayo zimakiwe *