TRANE BAS-SVN231D-EN Symbio 500 Programmable Controller

Imininingwane
- Isitoreji: Temperature: Relative Humidity: Between 5% to 95% (non-condensing)
- Ukusebenza: Temperature: Humidity: Between 5% to 95% (non-condensing)
- Amandla: Mounting Weight of Mounting surface must support 0.80 lb. (0.364 kg) Controller
- Ezemvelo: NEMA 1 Rating (Enclosure), Plenum Rating: Not plenum rated. The Symbio 500 must be mounted within a rated enclosure when installed in a plenum.
Imiyalo yokusetshenziswa komkhiqizo
Isitoreji Nezimo Zokusebenza
Ensure the controller is stored and operated within the specified temperature and humidity ranges to maintain optimal performance.
Iziyalezo zokukhweza
Ukukhweza idivayisi:
- Hook the device over the top of the DIN rail.
- Gently push on the lower half of the device in the direction of the arrow until the release clip clicks into place.
To remove/reposition the device:
- Nqamula zonke izixhumi ngaphambi kokukhipha noma ukubeka kabusha.
- Insert a screwdriver into the slotted release clip and gently pry upward to disengage the clip.
- While holding tension on the clip, lift the device upward to remove or reposition it.
- If repositioned, push on the device until the release clip clicks back into place to secure it on the DIN rail.
Isilawuli esihlelekayo se-Symbio 500 esinezinjongo eziningi sisetshenziswa kuhlu lwezinhlelo zokusebenza zokugcina.
Izexwayiso, Izexwayiso, kanye Nezaziso
Funda leli bhukwana ngokucophelela ngaphambi kokusebenzisa noma ukusevisa le yunithi. Izeluleko zokuphepha zivela kulo lonke leli bhukwana njengoba kudingeka. Ukuphepha kwakho siqu kanye nokusebenza kahle kwalo mshini kuncike ekunakekelweni okuqinile kwalezi zinyathelo zokuphepha.
Izinhlobo ezintathu zezeluleko zichazwa kanje:
- ISEXWAYISO Ibonisa isimo esingaba yingozi, okuthi uma singagwenywa, siphumele ekufeni noma ekulimaleni okubi kakhulu.
- ISEXWAYISO Ibonisa isimo esingaba yingozi, okuthi uma singagwenywa, siphumele ekulimaleni okuncane noma okulingene. Ingase futhi isetshenziselwe ukuxwayisa ngemikhuba engaphephile.
- ISAZISO Ibonisa isimo esingase sibangele imishini noma ukucekelwa phansi kwempahla kuphela izingozi.
Ukukhathazeka Okubalulekile Kwemvelo
Ucwaningo lwesayensi luye lwabonisa ukuthi amakhemikhali athile enziwe umuntu angathinta ungqimba lwe-ozone olwenzeka ngokwemvelo emhlabeni lapho ededelwa emkhathini. Ikakhulukazi, amaningana amakhemikhali akhonjiwe angase athinte ungqimba lwe-ozone iziqandisi ezine-Chlorine, iFluorine, ne-Carbon (ama-CFC) kanye nalawo aqukethe i-Hydrogen, i-Chlorine, i-Fluorine ne-Carbon (ama-HCFC). Akuzona zonke iziqandisi eziqukethe lezi zinhlanganisela ezinomthelela ofanayo emvelweni. I-Trane ikhuthaza ukuphathwa kahle kwazo zonke iziqandisi.
Imikhuba Ebalulekile Yokubamba Isiqandisi
U-Trane ukholelwa ukuthi ukwenza okufanele kwesiqandisi kubalulekile endaweni ezungezile, kumakhasimende ethu, nasembonini yesiqandisi. Bonke ochwepheshe abaphatha iziqandisi kufanele bagunyazwe ngokwemithetho yendawo. E-USA, i-Federal Clean Air Act (Isigaba 608) ibeka izimfuneko zokuphatha, ukubuyisela, ukubuyisela, nokugaywa kabusha kweziqandisi ezithile kanye nezinto zokusebenza ezisetshenziswa kulezi zinqubo zesevisi. Ngaphezu kwalokho, ezinye izifundazwe noma omasipala bangase babe nezidingo ezengeziwe okufanele zilandelwe ukuze kuphathwe ngendlela efanele iziqandisi. Yazi imithetho esebenzayo futhi uyilandele.
ISEXWAYISO
Kudingeka Izintambo Ezifanelekile Nezinsimu! Ukwehluleka ukulandela ikhodi kungaholela ekufeni noma ekulimaleni okubi kakhulu. Zonke izintambo zenkundla KUFANELE zenziwe ngabasebenzi abaqeqeshiwe. Izintambo ezifakwe ngendlela engafanele nezisekelwe phansi zenza izingozi ZOMLILO kanye ELECTROCUTION. Ukuze ugweme lezi zingozi, KUMELE ulandele izimfuneko zokufakwa kwezintambo zensimu kanye nokubeka phansi njengoba kuchazwe ku-NEC kanye namakhodi akho kagesi endawo/esifunda/kazwelonke.
ISEXWAYISO
Izisetshenziswa Zokuzivikela Zomuntu Siqu (i-PPE) Ziyadingeka!
Ukwehluleka ukugqoka i-PPE efanele emsebenzini owenziwayo kungaholela ekufeni noma ekulimaleni okubi kakhulu. Ochwepheshe, ukuze bazivikele ezingozini ezingaba khona zikagesi, zemishini, namakhemikhali, KUFANELE balandele izinyathelo zokuphepha kuleli bhukwana naseku tags, izitikha, namalebula, kanye nemiyalelo engezansi:
- Ngaphambi kokufaka/ukusevisa lolu phiko, ochwepheshe KUMELE bafake yonke i-PPE edingekayo emsebenzini owenziwayo (Ex.ampkancane; sika amagilavu/imikhono engazweli, amagilavu e-butyl, izibuko zokuphepha, isigqoko esiqinile/i-bump cap, isivikelo sokuwa, i-PPE kagesi kanye nezingubo ze-arc flash). NJALO ubhekise ku-Safety Data Sheets (SDS) kanye nemihlahlandlela ye-OSHA ukuze uthole i-PPE efanele.
- Lapho usebenza ngamakhemikhali ayingozi noma eduze nawo, NJALO ubhekise ku-SDS efanele kanye ne-OSHA/GHS (I-Global Harmonised System of Classification and Lebeling of Chemicals) ukuze uthole ulwazi olumayelana namazinga okuchayeka komuntu siqu avumelekile, ukuvikelwa okufanele kokuphefumula kanye neziyalezo zokusingatha.
- Uma kukhona ubungozi bokuthintana nogesi okunikwa amandla, i-arc, noma i-flash, ochwepheshe KUFANELE bafake yonke i-PPE ngokuvumelana ne-OSHA, NFPA 70E, noma ezinye izidingo eziqondene nezwe zokuvikela i-arc flash, NGAPHAMBI kokuseviswa kweyunithi. UNGALINGE WENZE UKUSHINTSHA, UKUNQUKA, NOMA IVOLTAGE UKUHLOLA NGAPHANDLE KWE-PPE KAgesi OKUFANELE KANYE NEZINGUBO ZE-ARC FLASH. QINISEKISA AMAMTERA KAgesi KANYE NEZINTHU ZOMSEBENZI KULINGANISWE KAHLE NGEVILI OKUHLOSIWEYOTAGE.
ISEXWAYISO
Landela Izinqubomgomo ze-EHS!
Ukwehluleka ukulandela imiyalelo engezansi kungaholela ekufeni noma ekulimaleni okubi kakhulu.
- Bonke abasebenzi be-Trane kufanele balandele izinqubomgomo zenkampani Zemvelo, Impilo, kanye Nezokuphepha (EHS) lapho benza umsebenzi ofana nomsebenzi oshisayo, ugesi, ukuvikela ukuwa, ukuvala isikhala/tagngaphandle, ukuphatha ngesiqandisi, njll. Lapho imithetho yendawo iqine kakhulu kunalezi zinqubomgomo, leyo mithetho ithatha indawo yalezi zinqubomgomo.
- Izisebenzi ezingezona eze-Trane kufanele zihlale zilandela imithetho yendawo.
ISEXWAYISO
Cancer and Reproductive Harm! This product can expose you to chemicals including lead and bisphenol A (BPA), which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Izixwayiso.ca.gov.
I-copyright
Le dokhumenti kanye nolwazi olukuyo kuyimpahla ye-Trane, futhi akumele isetshenziswe noma yenziwe kabusha iphelele noma ingxenye yayo ngaphandle kwemvume ebhaliwe. I-Trane igodla ilungelo lokubuyekeza lokhu kushicilelwa noma kunini, nokwenza izinguquko kokukuqukethe ngaphandle kwesibopho sokwazisa noma yimuphi umuntu ngalokho kubuyekezwa noma ushintsho.
Uphawu lokuhweba
All trademarks referenced in this document are the trademarks of their respective
abanikazi.
Uku-oda Izinombolo
Order Number/Description
- BMSY500AAA0100011 Symbio 500 Programmable Controller
- BMSY500UAA0100011 Symbio 500 Programmable Controller
Isitoreji/Imininingwane Yokusebenza
| Isitoreji | |
| Izinga lokushisa: | -67°F ukuya ku-203°F (-55°C kuya ku-95°C) |
| Umswakama Ohlobene: | Phakathi kuka-5% kuya ku-95% (okungafinyeleli) |
| Isebenza | |
| Izinga lokushisa: | -40°F ukuya ku-158°F (-40°C kuya ku-70°C) |
| Umswakamo: | Phakathi kuka-5% kuya ku-95% (okungafinyeleli) |
| Amandla: | 20.4–27.6 Vac (24 Vac, ±15% ngokulinganisa) 50–60 Hz, 24 VA
For specifics on transformer sizing, see Symbio™500Programmable Controller Installation, Operation, and Maintenance (BAS-SVX090*-EN). |
| Ukukhweza Isisindo Somlawuli: | Indawo yokukhweza kufanele isekele u-0.80 lb. (0.364 kg) |
| Isilinganiso Sendawo (Enclosure): | I-NEMA 1 |
| Isilinganiso se-Plenum: | Ayilinganisiwe i-plenum. I-Symbio 500 kufanele igxunyekwe ngaphakathi kwendawo ebiyelwe elinganiselwe uma ifakwe ku-plenum. |
Ukuthobela I-ejensi
- I-UL60730-1 PAZX (Isisetshenziswa sokulawula amandla esivulekile)
- Ukuvutha kwe-UL94-5V
- I-CE Imakiwe
- I-UKCA Imakiwe
- I-FCC Ingxenye 15, Ingxenye Engaphansi B, Umkhawulo Wekilasi B
- I-VCCI-CISPR 32:2016: Umkhawulo Wesigaba B
- AS/NZS CISPR 32:2015: Umkhawulo Wekilasi B
- INGABE ICES-003(B)/NMB-003(B)
Ubukhulu/Ukukhweza/Ukukhipha Isilawuli

Ukukhweza idivayisi:
- Huka idivayisi phezu kukaloliwe we-DIN.
- Cindezela kancane uhhafu ongezansi wedivayisi uqonde kumcibisholo kuze kube yilapho isiqeshana sokukhishwa sichofozwa endaweni.

Ukuze ususe/ubeke kabusha idivayisi:
- Nqamula zonke izixhumi ngaphambi kokukhipha noma ukubeka kabusha.
- Insert the screwdriver into slotted release clip and gently pry upward with the screwdriver to disengage the clip.
- While holding tension on the clip, lift the device upward to remove or reposition.

If repositioned, push on the device until the release clip clicks back into place to secure the device on the DIN rail. Slotted release clip shown from back side.
ISAZISO
Ukulimala Kwendawo! Ukwehluleka ukulandela imiyalelo engezansi kungadala umonakalo endaweni ebiyelwe ngepulasitiki. Ungasebenzisi amandla amakhulu ukufaka isilawuli kumzila wesitimela we-DIN. Uma usebenzisa ujantshi we-DIN womunye umkhiqizi, landela ukufakwa kwawo okunconyiwe.
ISEXWAYISO
Voltage! Ukwehluleka ukunqamula ugesi ngaphambi kokuseviswa kungaholela ekufeni noma ekulimaleni okubi kakhulu. Nqamula wonke amandla kagesi, okuhlanganisa nokunqanyulwa kwesilawuli kude ngaphambi kokusevisa. Landela ukukhiya okufanele/ tagkhipha izinqubo zokuqinisekisa ukuthi amandla awakwazi ukunikwa amandla ungahlosile. Qinisekisa ukuthi awekho amandla akhona nge-voltmeter.
ISEXWAYISO
Proper Ground Connection Required! Failure to follow instructions below could result in death or serious injury.After installation, ensure that the 24 Vac transformer is grounded through the controller. Measure the voltage phakathi komhlaba we-chassis nanoma iyiphi itheminali yaphansi kusilawuli. Umphumela olindelekile: Vac <4.0 volt.
Izidingo zocingo
Ukuqinisekisa ukusebenza kahle kwesilawuli, faka isekethe yokuphakela amandla ngokuhambisana nemihlahlandlela elandelayo:
- Isilawuli kufanele sithole amandla e-AC avela kumjikelezo wamandla ozinikele; ukwehluleka ukuthobela kungabangela isilawuli singasebenzi kahle.
- Iswishi yokunqamula isekethe yamandla ezinikele kufanele ibe eduze nesilawuli, ifinyeleleke kalula isisebenzisi, futhi imakwe njengedivayisi enqamulayo yesilawuli.
- UNGAZISEBENZISI izintambo zamandla e-AC kunqwaba yocingo efanayo nezintambo zokufaka/okukhiphayo; ukwehluleka ukuthobela kungabangela isilawuli singasebenzi kahle ngenxa yomsindo kagesi.
- I-18 AWG wire yethusi iyanconywa kumjikelezo phakathi kwe-transformer nesilawuli.
Izincomo ze-Transformer
The controller can be powered with 24VAC. Use of a 24 Vac power supply is recommended in order to use the spare 24 Vac outputs for powering relays and TRIACs.
- Izidingo zesiguquli se-AC: kufakwe kuhlu lwe-UL, isiguquli samandla se-Class 2, i-24 Vac ±15%, ubukhulu bedivayisi bomthwalo ongu-24 VA. I-transformer kufanele ilinganiswe ukuze inikeze amandla anele kusilawuli kanye nokuphumayo.
- Ukufakwa okuthobela i-CE: I-transformer kufanele imakwe i-CE futhi ihambisane ne-SELV ngamazinga e-IEC.
ISAZISO
Ukulimala Kwezisetshenziswa!
Sharing 24 VAC power between controllers could result in equipment damage
A separate transformer is recommended for each controller. The line input to the transformer must be equipped with a circuit breaker sized to handle the maximum transformer line current. If a single transformer is shared by multiple controllers:
- I-transformer kumele ibe nomthamo owanele
- I-polarity kufanele igcinwe kuso sonke isilawuli esinikwa amandla yi-transformer
Okubalulekile: Uma uchwepheshe ngokungaqondile ehlehlisa i-polarity phakathi kwezilawuli ezinikwa amandla yi-transformer efanayo, umehluko we-24 Vac uzokwenzeka phakathi kwezizathu zesilawuli ngasinye. Izimpawu ezilandelayo zingase zibe umphumela:
- Ukulahlekelwa okuncane noma okugcwele kokuxhumana kuso sonke isixhumanisi se-BACnet®
- Ukusebenza okungalungile kokuphumayo kwesilawuli
- Ukulimala kwe-transformer noma i-fuse ye-transformer eshaywayo
Izintambo ze-AC Power
To wire AC power
- Xhuma zombili izintambo zesibili kusukela ku-24 Vac transformer kuya kumatheminali e-XFMR kudivayisi.
- Qiniseka ukuthi idivayisi isisekelo esifanele.
Okubalulekile: This device must be grounded for proper operation! The factory-supplied ground wire must be connected from any chassis ground connection on the device (
) endaweni efanele yomhlaba (
). The chassis groundconnection used may be the 24 Vac transformer input at the device, or any other chassis ground connection on the device.
Qaphela: Idivayisi ayisekelwe ngoxhumano lukaloliwe lwe-DIN.
Qaphela: Uxhumano lwe-pigtail kufanele lusetshenziswe phakathi komhlabathi we-chassis kudivayisi kanye nomhlabathi, uma idivayisi ingekho phansi ngomlenze owodwa wezintambo ze-transformer.
Ukuqala Nokuhlola Amandla
- Qinisekisa ukuthi isixhumi esingu-24 Vac nendawo ye-chassis kunezintambo ezifanele.
- Idivayisi ngayinye kufanele ibe nekheli elihlukile nelivumelekile. Ikheli lisethwa kusetshenziswa amaswishi ekheli ajikelezayo. Amakheli avumelekile angu-001 kuya ku-127 wezinhlelo zokusebenza ze-BACnet MS/TP kanye no-001 kuya ku-980 wezinhlelo zokusebenza ze-Trane Air-Fi ne-BACnet IP.
Okubalulekile: A duplicate address or a 000 address will cause communication problems in a BACnet link: The Tracer SC+ will not discover all devices on the link, and the installation process will fail after discovery. - Susa i-lockout/tagaphume emgqeni voltage amandla ekhabetheni likagesi.
- Faka amandla kusilawuli bese ubheka ukulandelana kokuhlolwa kwamandla okulandelayo:
Amandla e-LED amalambu abomvu isekhondi elingu-1. Bese ishintsha ibe luhlaza, okubonisa ukuthi iyunithi iqaliswe kahle futhi ilungele ikhodi yohlelo. Ukukhanya okubomvu kubonisa ukuthi kunezimo zephutha ezikhona. Ithuluzi lesevisi ye-Tracer® TU lingasetshenziswa ukuhlola izimo zephutha ngemva kokulayishwa kwekhodi yohlelo lokusebenza kanye nezinhlelo ze-TGP2.
Izintambo Okokufaka/Okukhiphayo
ISAZISO
Ukulimala Kwezisetshenziswa!
Failure to follow instructions below could result in damage to the controller, power transformer, or input/output devices due to inadvertent connections to power circuits. Remove power to the controller before making input/output connections. Pre-power checks of input/output devices should be performed according to the Symbio™500 Programmable Controller – Installation, Operation, and Maintenance (BAS-SVX090*-EN). Maximum wire lengths are as follows:
| Ubude Obuningi Bezintambo | ||
| Uhlobo | Okokufaka | Imiphumela |
| Kanambambili | 1,000 ft (300 m) | 1,000 ft (300 m) |
| 0 - 20 mA | 1,000 ft (300 m) | 1,000 ft (300 m) |
| 0 – 10 Vdc | 300 ft (100 m) | 300 ft (100 m) |
| I-Thermistor/Imelana | 300 ft (100 m) | Akufaneleki |
| • All wiring must be in accordance with the NEC and local codes.
• Use only 18–22 AWG (1.02 mm to 0.65 mm diameter), stranded, tinned-copper, shielded, twisted-pair wire. • Analog and 24 Vdc output wiring distances are dependent on the receiving unit specifications. • DO NOT run input/output wires or communication wires in the same wire bundle with AC power wires. |
||
Tug Test for Terminal Connectors
If using terminal connectors for wiring, strip the wires to expose 0.28-inch (7 mm) of bare wire. Insert each wire into a terminal connector and tighten the terminal screws. A tug test is recommended after tightening terminal screws to ensure that all wires are secure.
I-BACnet MS/TP Link Wiring
Izintambo zesixhumanisi se-BACnet MS/TP kufanele zinikezwe inkambu futhi zifakwe ngokuhambisana ne-NEC namakhodi endawo. Ngaphezu kwalokho, ucingo kufanele lube uhlobo olulandelayo: i-capacitance ephansi, i-gauge engu-18, i-stranded, ithusi eliboshwe, elivikelekile, elisontekile. I-polarity kufanele igcinwe phakathi kwawo wonke amadivayisi akusixhumanisi.
I-BACnet IP Wiring
The Symbio™ 500 supports BACnet IP. The device requires a category 5E or newer Ethernet cable with an RJ-45 plug connector. The cable can be plugged into either port on the controller.
Exampizintambo ze-Wiring
Analog Input/Output Wiring Terminals Are Top Tier

I-TRIAC Supply Wiring
High-side Ukushintsha; indlela ye-wiring ejwayelekile
Ukushintsha ohlangothini oluphansi; kunciphisa ubungozi bokushiswa okuphumayo kanambambili ngenxa yezikhindi ezingaqondile phansi. 
Ukucaciswa Kokokufaka/Okukhiphayo
| Uhlobo lokokufaka/okukhiphayo | Qty | Izinhlobo | Ibanga | Amanothi |
|
Okokufaka kwe-Analog (AI1 ukuya ku-AI5)) |
5 |
Umeluleki |
10kΩ – Uhlobo II, 10kΩ – Uhlobo III, 2252Ω – Uhlobo II,
20kΩ – Uhlobo IV, 100 kΩ |
Lokhu okokufaka kungalungiselelwa amandla okukhipha anesikhathi. Isekela *, ** ngezinzwa ze-Trane Zone. |
|
I-RTD |
I-Balco™ (Ni-Fe) 1kΩ, 385 (Pt) 1kΩ, 375 (Pt) 1kΩ, 672 (Ni) 1kΩ, |
- |
||
| I-Setpoint (Thumbwheel) | 189Ω ukuya ku-889Ω | - | ||
| Ukungazweli | 100Ω ukuya ku-100kΩ | Ivamise ukusetshenziselwa ukushintsha isivinini sabalandeli. | ||
|
Okokufaka okujwayelekile (UI1 ne-UI2) |
2 |
Umugqa Wamanje | 0-20mA |
Lokhu okokufaka kungase kulungiselelwe ukuthi kube okokufaka kwe-thermistor noma okuphikisayo, okokufaka kwe-0–10 Vdc, noma okokufaka okungu-0–20 mA. |
| I-Linear Voltage | 0–10Vdc | |||
|
Umeluleki |
10kΩ – Uhlobo II, 10kΩ – Uhlobo III, 2252Ω – Uhlobo II,
20kΩ – Uhlobo IV, 100 kΩ |
|||
|
I-RTD |
I-Balco™ (Ni-Fe) 1kΩ, 385 (Pt) 1kΩ, 375 (Pt) 1kΩ, 672 (Ni) 1kΩ, | |||
| I-Setpoint (Thumbwheel) | 189 W kuya ku-889 W | |||
| Ukungazweli | 100Ω ukuya ku-100kΩ | |||
| Kanambambili | Oxhumana naye omile | Oxhumene naye odluliselwe okungenasici. | ||
| I-Pulse Accumulator | Umqoqi ovulekile wesimo esiqinile | Isikhathi esincane sokuhlala singama-millisecond angama-25 ON kanye nama-millisecond angama-25 VALIWE. | ||
| Okokufaka kanambambili (BI1 ukuya ku-BI3) |
3 |
- |
24 I-Vac detect |
Isilawuli sihlinzeka nge-24Vac edingekayo ukuze ushayele okokufaka kanambambili uma usebenzisa ukuxhumana okunconyiwe. |
| Okukhipha kanambambili (BO1 ukuya ku-BO3) |
3 |
I-Form C Relay |
0.5A @ 24Vac umsebenzi womshayeli |
Ububanzi obunikeziwe bungothintana naye ngamunye. Amandla adinga ukuxhunywa ngentambo kokuphumayo kanambambili. Yonke imiphumela ihlukanisiwe komunye nomunye futhi kusukela emhlabathini noma amandla. |
| Okukhipha kanambambili (BO4 ukuya ku-BO9) |
6 |
I-Triac |
0.5A @ 24Vac umsebenzi wokumelana nomsebenzi womshayeli |
Ububanzi obunikeziwe bungokuthintana ngakunye futhi amandla avela kumjikelezo we-TRIAC SUPPLY. Sebenzisa ukulungisa ama-TRIAC. Umsebenzisi unquma ukuthi uyavala yini uhlangothi oluphezulu (ukunikeza voltage kumthwalo ophansi) noma ohlangothini oluphansi (ukunikeza indawo ekulayishweni kwamandla). |
|
AnalogOutput/BinaryInput (AO1/BI4 and AO2/BI5) |
2 |
Umugqa Wamanje | 0 - 20mA |
Ukunqanyulwa ngakunye kufanele kulungiselelwe njengokuphumayo kwe-analog noma okokufaka kanambambili. |
| I-Linear Voltage | 0 - 10Vdc | |||
| Okufakwayo kanambambili | Oxhumana naye omile | |||
| Pulse Ububanzi Ukushintshashintsha Kwezwi | Isignali engu-80 Hz @ 15Vdc | |||
| Okokufaka Kwengcindezi (PI1 kanye ne-PI2) |
2 |
- |
0 – 5 Ku-H20 |
Okokufaka kwengcindezi okuhlinzekwa ngamavolthi angu-5 (okudizayinelwe ama-transducer e-Kavlico™). |
| Ingqikithi yephoyinti | 23 | - | - | - |
Qaphela: Okuphumayo kanambambili kwe-Symbio 500 akuhambisani ne-voltages over 24 Vac.
Amamojula Wokunweba
If additional inputs/outputs are needed, the Symbio™ 500 will support an additional 110 (133 total) inputs/outputs. See Tracer XM30, XM32, XM70, and XM90 Expansion Modules – Installation, Operation, and Maintenance (BAS-SVX46*-EN) for more information.
Amamojula we-Wi-Fi
Uma i-Trane Wi-Fi isetshenziswa, i-Symbio 500 isekela noma iyiphi imojula:
- X13651743001 Ikhithi Yenkundla Efakiwe ye-Wi-Fi, ikhebula elingu-1 m, 70C
- X13651743002 Ikhithi Yenkundla Efakiwe ye-Wi-Fi, ikhebula elingu-2.9 m, 70C
I-Trane - yi-Trane Technologies (i-NYSE: TT), umqambi wesimo sezulu womhlaba wonke - idala izindawo zasendlini ezikahle, ezonga ugesi zezinhlelo zokuhweba nezokuhlala. Ngeminye imininingwane, sicela uvakashele i-trane.com noma i- minengabe.com. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.BAS-SVN231D-EN 07 Oct 2025 Supersedes BAS-SVN231C-EN (Apr 2023)
imibuzo ejwayelekile ukubuzwa
Ubani okufanele afake futhi asevise okokusebenza?
Only qualified personnel should install and service the equipment as it involves specific knowledge and training to prevent hazardous situations.
What are the environmental ratings for the controller?
The controller has a NEMA 1 enclosure rating and is not plenum rated. It must be mounted within a rated enclosure when installed in a plenum.
What are the consequences of improper field wiring and grounding?
Improper field wiring and grounding could pose fire and electrocution hazards, emphasizing the importance of following code requirements and having qualified personnel perform all field wiring.
Why is personal protective equipment (PPE) required?
Failure to wear proper PPE could result in death or serious injury due to potential electrical, mechanical, and chemical hazards. Technicians must follow precautions to protect themselves.
Amadokhumenti / Izinsiza
![]() |
TRANE BAS-SVN231D-EN Symbio 500 Programmable Controller [pdf] Umhlahlandlela wokufaka BAS-SVN231D-EN, BAS-SVX090 -EN, BAS-SVN231D-EN Symbio 500 Programmable Controller, BAS-SVN231D-EN, Symbio 500 Programmable Controller, 500 Programmable Controller, Programmable Controller, Controller |