MADx Stop Solution Iziyalezo

DESCRIPTION
I-Stop Solution isetshenziswa ngesikhathi sokucutshungulwa kwamalungu afanayo asekelwe kubuchwepheshe be-ALEX njengoba kuchazwe emiyalweni yawo yokusebenzisa. I-Stop Solution ingasetshenziswa kuzo zombili izinqubo ezenziwa ngesandla kanye nezizenzakalelayo ngabasebenzi baselabhorethri abaqeqeshiwe kanye nochwepheshe bezokwelapha.
I-Stop Solution isetshenziswa ngesikhathi sokuhlolwa ukumisa ukusabela kombala kuma-array.
Lo Myalelo Wokusetshenziswa uyasebenza kumkhiqizo olandelayo:

INHLOSO OKUHLOSIWEYO
I-Stop Solution iyisesekeli sokuhlola okusekelwe kubuchwepheshe be-ALEX.
Umkhiqizo wezokwelapha we-IVD usetshenziswa njengoba kukhonjisiwe kuZiyalezo Zokusetshenziswa ezifanele futhi usetshenziswa izisebenzi zaselabhorethri eziqeqeshiwe kanye nochwepheshe bezokwelapha elabhorethri yezokwelapha.
Sicela ufunde Imiyalo Yokusebenzisa ngokugcwele. Lena ukuphela kwendlela yokuqinisekisa ukuthi umkhiqizo usetshenziswa ngendlela efanele. Umkhiqizi akamukeli isibopho sokusebenzisa okungalungile noma ukuguqulwa okwenziwe umsebenzisi.
UKUTHUMELA KANYE NESIGCINI
Ukuthunyelwa kwe-Stop Solution kwenzeka ezingeni lokushisa elizungezile.
I-reagent kufanele igcinwe ku-2 - 8 ° C kuze kube yilapho isetshenziswa. Uma igcinwe kahle, i-reagent izinzile kuze kube usuku lokuphelelwa yisikhathi olushiwo.
UKULAHLWA KWEMFUCUZA
Ama-reagents asetshenzisiwe futhi angasetshenzisiwe angalahlwa nemfucuza yaselabhorethri. Kufanele kulandelwe yonke imithetho kazwelonke neyasekhaya.
UHLU LWEZIMFANEKISO

AMA-REAGENTS KANYE NEMATERIAL
I-Stop Solution ipakishwe ngokwehlukana. Idethi yokuphelelwa yisikhathi kanye nezinga lokushisa lokulondoloza kubonisiwe kulebula. Ama-reagents akufanele asetshenziswe ngemuva kosuku lwawo lokuphelelwa yisikhathi.

I-Stop Solution isilungele ukusetshenziswa. Gcina ku-2 - 8 °C kuze kube usuku lokuphelelwa yisikhathi. Ngaphambi kokusetshenziswa, ikhambi kufanele ilethwe ekamelweni lokushisa. Isixazululo esivuliwe sizinzile izinyanga eziyi-6 ku-2 - 8 °C.
Ingaguqubala uma igcinwe isikhathi eside. Lokhu ayithinti imiphumela yokuhlolwa.
Ingaguqubala uma igcinwe isikhathi eside. Lokhu ayithinti imiphumela yokuhlolwa.
IZIXWAYISO NEZIQINISEKISO
- Kutuswa ukusebenzisa amagilavu, izibuko zokuphepha kanye nejazi laselabhu lapho uphatha iziguliampama-les nama-reagents, kanye nokulandela umkhuba omuhle waselabhorethri (GLP).
- Ama-reagents asetshenziselwa ukusetshenziswa kwe-in vitro kuphela futhi akufanele asetshenziselwe ukusetshenziswa kwangaphakathi noma kwangaphandle kubantu noma ezilwaneni.
- Lapho ukulethwa, iziqukathi kufanele zibhekwe ukuthi azikho yini umonakalo. Uma noma iyiphi ingxenye yonakele (isb, isiqukathi sebhafa), sicela uthinte i-MADx (support@madx.com) noma umsabalalisi wangakini. Ungasebenzisi izingxenye zekhithi ezilimele, lokhu kungase kuthinte ukusebenza kwekhithi.
- Ungasebenzisi izingxenye zekhithi eziphelelwe yisikhathi.
IZIHLOKO EZIDINGEKAYO ZOKUQUQUZWA NOKUHLAZIYA
Izinto ezidingekayo ezitholakala ku-MADx, ezingafakiwe kukhithi:
- I-ImageXplorer
- MAX idivayisi
- I-RAPTOR SERVER Analysis Software
- I-ALEX² I-Allergy Xplorer
- I-FOX Ukudla Xplorer
- Igumbi lokufukamela
- I-Shaker (bona i-ALEX²/FOX ukuze uthole imininingwane enemininingwane)
- Abaphathi be-array (ongakukhetha)
Izinto ezisetshenziswayo ezidingekayo azitholakali kwa-MADx:
- Ama-Pipettes
- Amanzi Acwebile
UKUSEBENZA KANYE NENKQUBO
Sebenzisa i-Stop Solution ngokuhambisana nenqubo efanele. Ukuze uthole ulwazi olwengeziwe, bheka i-MAX Devices Instruction for Use noma Imiyalo Yokusetshenziswa kwekhithi yokuhlola ye-MADx ehambisanayo.
Izici zokusebenza kokuhlaziya:
I-Stop Solution ihloselwe ukusetshenziswa kuphela ngokuhambisana nezivivinyo ezisekelwe kubuchwepheshe be-ALEX. Umkhiqizo awenzi ukuhlaziya noma ukuhlaziya umtholampilo ngokwawo.
I-Stop Solution ihloselwe ukusetshenziswa kuphela ngokuhambisana nezivivinyo ezisekelwe kubuchwepheshe be-ALEX. Umkhiqizo awenzi ukuhlaziya noma ukuhlaziya umtholampilo ngokwawo.
IWARANTI
Idatha yokusebenza evezwe lapha itholwe kusetshenziswa inqubo ebonisiwe. Noma yiluphi ushintsho kwinqubo lungashintsha imiphumela. I-MacroArray Diagnostics ichitha noma iyiphi iwaranti ezimeni ezinjalo. Lokhu kuthinta isiqinisekiso esisemthethweni kanye nokusebenziseka. I-MacroArray Diagnostics kanye nabasabalalisi bayo bendawo ngeke bathweswe icala nganoma yimuphi umonakalo kulezi zimo.
SHINTSHA UMLANDO

© Copyright by MacroArray Diagnostics
I-MacroArray Diagnostics (MADx)
I-Lemböckgasse 59, Top 4
1230 Vienna, Austria
+43 (0)1 865 2573
www.madx.com
I-MacroArray Diagnostics (MADx)
I-Lemböckgasse 59, Top 4
1230 Vienna, Austria
+43 (0)1 865 2573
www.madx.com
Inombolo yenguqulo: 00-07-IFU-01-EN-03
Idethi yokukhishwa: 09-2024
Idethi yokukhishwa: 09-2024