LCGATEWAY/OFC
Umhlahlandlela wokufaka
Office Gateway Manual
LCGATEWAY-OFC Office Gateway
Welcome to lighting control that just works.
Lightcloud is a wireless, cloud-based lighting control system that’s incredibly easy to install. There’s no networking or complicated dip switches. Just wire the devices for power and let us know what was installed.
Okuqukethwe
- I-Office Gateway
- Intambo Yamandla
- I-Mounting Bracket
- Izikulufo zokukhweza x2
- Device ID Labels
- Imanuwali
- Isitika Sephaneli
Imininingwane Yedivayisi
INGXENYE INOMBOLO: LCGATEWAY/OFC
OKUSEBENZA KWETEMPERATURE: 0 kuya ku-40ºC
MAXIMUM RELATIVE HUMIDITY: 95%
STORAGE AND TRANSPORTATION TEMPERATURE: -20 kuya ku-40ºC
IZIBALO: 4.97” X 4.97” X 1.5”
OKUFAKAYO KWAMANDLA E-AC: Only use with provided power cord.
I NPUT VOLTAGE: 120 VAC, 50/60 HZ
UKUSEBENZISA AMANDLA: 60 mA @ 120V
Okwenziwe ngokwezifiso eChina
Copyright © 2025 RAB Lighting, Inc.
Uhlelo Olungaphezuluview
Lightcloud is a wireless, networked lighting control system that enables near limitless control over lighting. Lightcloud can be accessed from nearly anywhere and any device by logging in to control.lightcloud.com.
Lightcloud comes with 10 years of unlimited support, so feel free to contact us if you have any questions at 1 (844) LIGHTCLOUD.
Of fice Gateway
The Lightcloud Of fice Gateway serves two main functions:
- On-Site Coordination of Devices. The Office Gateway acts as an on-site brain for up to 200 Lightcloud® devices.
- Off-Site Coordination with Lightcloud.
The Office Gateway communicates with the Lightcloud® cloud for complete control of your system from anywhere.
An unlimited number of Gateways can be used for wireless control of any size Site.
Ukufakwa
- ISINYATHELO SOKUQALA
Misa iSango
a. Avoid problem materials and devices.
The Gateway needs to be able to communicate wirelessly with other Lightcloud Devices. Don’t place the
Gateway in a metal enclosure, thick concrete or brick rooms. Also, don’t place the Gateway near microwaves, elevator rooms, amplifiers, or other antennas.
PROBLEM MATERIALSPROBLEM DEVICES & SIGNALS
AMA-MICROWAVES ELEVATOR MECHANICAL ROOMS AMPLIFIERS & ANTENNAS b. Choose a location that is as close to as many other Lightcloud devices as possible.
*All of the devices don’t have to be within a 100’ of the Gateway, but its ideal to have as many within direct range as possible.
- ISINYATHELO SESIBILI
Record the Gateway’s Device ID Each Lightcloud device has a unique Device ID for identification that needs to be documented. To document the Device IDs, use one of the following 3 methods.
a. LC Installer App – Free Scan Device IDs and send information to RAB Download: lightcloud.com/lcinstaller (Iyatholakala ku-iOS ne-Android)b. Device Table – Included with the Gateway
Attach Device ID stickers to Device Table and complete information.
Send detailed photos of completed device table to support@lightcloud.com
Additional Device Tables can be downloaded at lightcloud.com/devicetablec. Floor Plan
Attach the Device Identification sticker to its location on a floor plan, lighting design, or design schedule. Send detailed photos of completed plans to support@lightcloud.com. - ISINYATHELO SESITHATHU
Faka i-Gateway
a. Place Gateway on a surface or mount Gateway to wall using bracket and 2 supplied screws.
b. If using ethernet, plug in ethernet cable.
c. Plug in power cable.
d. Verify system statusOnce all LEDs are solid white, you should be able to connect to your Gateway from control.lightcloud.com or the Lightcloud® Mobile App.
To check ZigBee (Device Mesh) signal strength, press the recessed device button once. A number of LEDs will turn blue indicating how strong the signal is, from 1 to 4, counting from the bottom up.Umbuso we-LED Incazelo All LEDs solid white Ukugijima ngokujwayelekile All LEDs pulsing white Iyaqala Some LEDs solid blue ZigBee signal strength All LEDs solid red Ukwehluleka okubalulekile All LEDs pulsing red Alukho uxhumano All LEDs pulsing green Gateway is in join mode - ISINYATHELO SESINE
Install and Document Other Lightcloud® Devices a. Follow the Device Manuals to wire the other devices for permanent, unswitched power.
b. As you wire each device, document their Device IDs using the same method you chose to document the Gateway’s Device ID in step 3. - ISINYATHELO SESIHLANU
Submit Device Information After wiring and organizing all the devices, submit the device information using the LC Installer App or email photos of the documented device IDs to support@lightcloud.com. - ISINYATHELO SESITHUPHA
Usuqedile!
Lightcloud Support will remotely configure the system.
Imininingwane yeCCC:
Le divayisi ithobela Ingxenye 15 Yemithetho ye-FCC. Ukusebenza kungaphansi kwemibandela emibili elandelayo:
1. Lolu cingo angeke lubangele ukuphazamiseka okuyingozi, futhi 2. Lolu cingo kufanele lwamukele noma yikuphi ukuphazamiseka okutholiwe, okuhlanganisa ukuphazamiseka okungase kubangele ukusebenza okungafuneki.
Qaphela: Le divayisi ihloliwe futhi yatholwa ukuthi ithobela imikhawulo yamadivayisi edijithali Yekilasi B ngokususelwe Ingxenye 15 Yengxenye Encane B, yemithetho ye-FCC. Le mikhawulo iklanyelwe ukuhlinzeka ngokuvikeleka okufanele ekuphazamisekeni okuyingozi endaweni yokuhlala. Lesi sixhobo sikhiqiza, sisebenzise, futhi singakhipha amandla efrikhwensi yomsakazo, futhi uma singafakiwe futhi sisetshenziswa ngokuhambisana nemanuwali yemiyalelo, singadala ukuphazamiseka okuyingozi ezokuxhumana ngomsakazo. Nokho, asikho isiqinisekiso sokuthi ukuphazamiseka ngeke kwenzeke ekufakweni okuthile. Uma lesi sisetshenziswa sidala ukuphazamiseka okuyingozi emsakazweni noma kumabonakude, okunganqunywa ngokucisha nokuvula okokusebenza, umsebenzisi uyakhuthazwa ukuthi azame ukulungisa ukuphazamiseka ngesinyathelo esisodwa noma ngaphezulu kwezilandelayo:
– Hlehlisa noma hambisa uthi olwamukelayo.
- Khulisa ukuhlukaniswa phakathi kwemishini nomamukeli.
– Xhuma okokusebenza endaweni yokuphuma kuyisekethe ehlukile kuleyo lapho umamukeli axhumeke khona.
- Xhumana nomthengisi noma uchwepheshe werediyo/TV onolwazi ukuze uthole usizo.
To comply with the FCC’s RF exposure limits for general population / uncontrolled exposure, this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in
ngokuhlangana nenye i-antenna noma i-transmitter.
ISEXWAYISO: Izinguquko noma ukuguqulwa kwalesi sisetshenziswa esingagunyazwanga ngokucacile i-RAB Lighting kungase kuqede igunya lomsebenzisi lokusebenzisa lesi sixhobo.
Amadokhumenti / Izinsiza
![]() |
Lightcloud LCGATEWAY-OFC Office Gateway [pdf] Umhlahlandlela wokufaka LCGATEWAY-OFC, LCGATEWAY-OFC Office Gateway, Office Gateway, Gateway |