VIKELA IMPILO YAKHO UFUNDE INCWADI YOKUSEBENZA
This Operating Manual is part of the device IS-IM1x.1. This Operating Manual provides important information for safe use of the device.
Ngaphambi kokusebenzisa idivayisi, funda le Manuwali Yokusebenza ngokucophelela futhi unake ngokukhethekile isigaba esithi "Imithetho Yokuphepha Efanele Kakhulu" kanye nezixwayiso ezigqanyiswe ngophawu oluyisixwayiso. Uma ungayilandeli le miyalo noma ungayiqondi, lokhu kungaholela ekufeni, ukulimala kanzima kanye nokulimala kocingo.
Qiniseka ukuthi uyakwazi ukufinyelela le Manuwali Yokusebenza uma uyidinga. Ungathola i-Operating Manual yamanje kokuthi www.isafe-mobile.com/en/support/downloads
Landela yonke imiyalelo enikezwe ocingweni nasephaketheni.
Landela imithetho yokuphepha yendawo.
Follow all laws, standards and directives for use, installation and project engineering.
Sebenzisa kuphela idivayisi ezindaweni eziyingozi eziqhumayo zezoni 1/21 kanye no-2/22 noma ngaphandle kwezindawo eziyingozi eziqhumayo.
Ungalulungisi ucingo ngokwesakhiwo.
Ungaluvuli ucingo noma uzilungise ngokwakho.
IMITHETHO EBALULEKILE EKUPHEPHENI
Use of this device assumes that the personnel observes the conventional safety regulations and has read and understood Operating Manual, Safety Instructions and certificate.
Uma isetshenziswa ezindaweni eziyingozi yokuqhuma, le miyalo elandelayo yokuphepha kufanele futhi ithotshelwe:
The device IS-IM1x.1 may only be used in zones 1/21 or 2/22 and ordinary none ex-hazardous areas.
Use of the device in areas other than those specified, or any modifications to the product, are not allowed and will void any warranties provided by i.safe MOBILE GmbH.
The device must be installed in an enclosure with at least degree of protection IP54.
The enclosure must meet the requirements of a recognized type of protection in accordance with EN/IEC 60079-0.
The device may only be operated in a clean, undamaged condition.
The housing of the device must not be opened.
Idivayisi ingase ingavezwa kunoma yimaphi ama-asidi anolaka noma ama-alkali.
For electrical systems, the relevant installation and operational regulations must be considered, such as Directive 2014/34/EU, EN/IEC 60079-14, and the applicable national standards.
Assembly, disassembly, installation, and commissioning must be carried out exclusively by qualified personnel with the necessary expertise in installing electrical components in hazardous areas.
The installation and operational conditions of hazardous plants must be carefully considered during mounting and operation.
The operator of electrical installations in hazardous environments is accountable for maintaining the device in optimal condition, ensuring its proper functionality, monitoring its performance, and performing necessary maintenance and repairs.
It must be ensured that all general safety regulations and standards for accident prevention and environmental protection are followed.
AMAPHUTHA NOKULIMALA
If there is any reason to suspect that the safety of the device has been compromised, it must be withdrawn from use. Measures must be taken to prevent any accidental restarting of the device. The safety of the device may be compromised, if, for example:
Ukungasebenzi kahle kwenzeka.
Izindlu zedivayisi zibonisa ukulimala.
Idivayisi ivezwe ekulayisheni ngokweqile.
Ukumakwa noma amalebula kudivayisi awafundeki.
Sincoma ukuthi idivayisi ebonisa amaphutha noma lapho kusoleka iphutha ukuthi ibuyiselwe ku-i.safe MOBILE GmbH ukuze ihlolwe.
UKUSETSHENZISWA OKUHLOSIWE
The IS-IM1x.1 is an Interface Module for data transfer and maintaining battery charging level of the IS940.x/IS945.x tablet, mounted in the IS-DS940.1 Docking Station. It is suitable for use in explosion hazardous areas of Zone 1/21 and 2/22, in accordance with Directives 2014/34/EU, 1999/92/EC and the IECEx system, among others.
Sebenzisa kuphela idivayisi njengoba kuchazwe kule Manuwali Yokusebenza. Noma yikuphi okunye ukusetshenziswa kuthathwa njengokungalungile futhi kungaholela ekufeni, ukulimala okubi kanye nokulimala kocingo.
Umkhiqizi i.safe MOBILE GmbH akathwesi icala ngomonakalo odalwe ukusetshenziswa okungafanele. Iwaranti iphelelwa yisikhathi uma kwenzeka ukusetshenziswa ngendlela engafanele.
INSTALLATION PERSONNEL
Only personnel who are authorised and qualified to install electrical components in explosion hazardous areas and who have read and understood the Operating Manual may assemble, disassemble and install this device.
USER
Abasebenzisi abaqeqeshiwe kuphela abafanelekele ukusetshenziswa kwamadivayisi e-Ex ezindaweni eziyingozi eziqhumayo futhi abafunde baqonda le Manuwali Yokusebenza abangasebenzisa le divayisi.
IWARANTI
Ungathola izimo zewaranti ku www.isafe-mobile.com/en/support/service
ISIMEMEZELO SE-EU SOKUVUMELANA
Uzothola isimemezelo se-EU sokuvumelana ku www.isafe-mobile.com/en/support/downloads
EX MAMAKI
I-ATEX:
II 2G Ex eb mb [ib Gb] IIC T4 Gb
II (2)D [Ex ib Db] IIIC
I (M1) [Ex ia Ma] I
Isitifiketi Sokuhambisana:
I-EPS 25 ATEX 1 001 X
I-CE-designation: 2004
IECEx:
Ex eb mb [ib Gb] IIC T4 Gb
[Ex ib Db] IIIC
[Ex ia Ma] I
IECEx Certificate: IECEx EPS 25.0001 X
Ibanga lokushisa:
-20 °C ≤ Ta ≤ +60 °C (EN/IEC 60079-0)
-10 °C ... +50 °C (EN/IEC 62368-1)
Kwenziwe ngu:
i.ukuphepha MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen Germany
UBUNTU BOKUDILIVA
Iphakheji yedivayisi yakho iqukethe okulandelayo:
1 x IS-IM1x.1
1 x Imiyalo yokuphepha
1 x interface cable
IDIVAYISI IYAQHUBEKAVIEW

- INTERFACES X1, X2
- INTERFACES X3, X4, X5, X6
- BRACKET FOR DIN RAIL MOUNTING
UKUFAKA
INGOZI
Incorrect installation can result in death or severe injuries!
Only install the device if you are authorised and qualified to install electrical components in explosion hazardous areas.
Only install the device regarding EN IEC 60079-14.
I-WIRING

STRIPPING THE INTERFACE CABLE

IMIHLANGANO
| X1 | IS-DS940.1 Host Interface | |
| X2 | USB 1.1 Ex i | Uo = 5,36 V Io = 231 mA I-Po = 0,624 W Co = 65 µF Lo = 1,1 mH Um = 63 V |
| X3 | 24 Okokufaka Amandla e-VDC | ![]() |
| X4 | I-Ethernet | ![]() |
| X5 | USB 2.0 Exe | ![]() |
| X6 | USB BUS Exe | ![]() |
IZIDINGO ZOKUKHUPHA
| DIN rail Mounting IEC/EN 60715 | TH 35 x 7,5 |
| Ukukhweza Direction | noma yikuphi |
| Indlela Yokuxhuma | Push-in Spring Connection |
| I-conductor cross section iqinile | - 0,2 mm2… 1,5 mm2 (When connecting and possibly adjusting a solid conductor of 1.5 mm2, the mechanical lateral forces, which can affect the terminal block, must be absorbed by lateral support.) - 0,34 mm2… 1,5 mm2 (Push-in connection) |
| I-conductor cross section iyavumelana nezimo | 0,2 mm2… 1,5 mm2 |
| I-Conductor cross section AWG | 24… 16 |
| Conductor cross section flexible, with ferrule with or without plastic sleeve | - 0,25 mm2 … 0,75 mm2 (Conductor connection with open terminal point) - 0,5 mm2 … 0,75 mm2 (Push-in connection) |
| Ubude bokukhumula | 8 mm |
IS PARAMETERS X2 – USB 1.1 EX I
The maximum permissible ratings for the external capacitance (Co) and inductance (Lo) are listed in the following table and are only valid for the single occurrence of the capacitance (Co) or inductance (Lo).
| I-IIC | IIB | IIA | |
| Lo | 1,1 mH | 4,6 mH | 6,4 mH |
| Co | 65µF | 1000µF | 1000µF |
For the simultaneous occurrence of the external capacitance (Co) and inductance (Lo) the permissible combinations must be taken from the following table.
| I-IIC | IIB | IIA | |||
| Lo | Co | Lo | Co | Lo | Co |
| 1,100 mH | 1,8µF | 4,600 mH | 7,3µF | 6,400 mH | 9,5µF |
| 0,500 mH | 2,9 µf | 1,000 mH | 16µF | 1,000 mH | 22µF |
| 0,100 mH | 5,5µF | 0,100 mH | 36µF | 0,100 mH | 49µF |
| 0,050 mH | 7,0µF | 0,010 mH | 130µF | 0,050 mH | 67µF |
| 0,010 mH | 14µF | 0,005 mH | 350µF | 0,010 mH | 210µF |
| 0,001 mH | 65µF | 0,002 mH | 1000µF | 0,002 mH | 1000µF |
IZINKINGA ZEDIVAYISI EZINGAKHONA
Ungathola ulwazi ngezinkinga ezingaba khona zedivayisi nokuthi ungazilungisa kanjani ku www.isafe-mobile.com/en/support/service ngaphansi kwento yemenyu ethi “FAQ”.
Uma uneminye imibuzo, sicela uthinte isevisi yokulungisa ye-i.safe MOBILE GmbH kokuthi www.isafe-mobile.com/en/support/service
UKUDLA/UKULUNGISA
Idivayisi ngokwayo ayinazo izingxenye ezisebenzisekayo.
ISEXWAYISO
Ukulungisa okungalungile kuletha ingozi yokuqhuma noma yomlilo, okungaholela ekufeni noma ukulimala kanzima! Ungaluvuli ucingo noma uzilungise ngokwakho.
Xhumana nesevisi yokulungisa ye-i.safe MOBILE GmbH kokuthi www.isafe-mobile.com/en/support/service uma ucingo lungasebenzi ngendlela evamile, uma ucingo ludinga ukulungiswa noma kudingeka enye ingxenye.
BUYISA UKUTHUNYELWA
Xhumana nesevisi yokulungisa ye-i.safe MOBILE GmbH kokuthi www.isafe-mobile.com/en/support/service
UZAkwethu Wokusabalalisa
Ungathola uzakwethu wokusabalalisa onguchwepheshe onesibopho ngezwe lakini www.isafe-mobile.com/en/contact
UKUHLANZA
ISAZISO
Ukuhlanzwa okungalungile kungabangela umonakalo ocingweni. Sicela uqaphele okulandelayo lapho uhlanza:
Nqamula idivayisi kusokhethi yamandla ngaphambi kokuhlanza.
Remove the IS940.x/IS945.x from the IS-IM1x.1.
Ungasebenzisi ama-chemical agents ukuhlanza.
Hlanza idivayisi ngendwangu ethambile, eswakanyiswe ye-antistatic.
ISITOREJI
ISAZISO
Incorrect storage can cause damage to the device. Store the device at a humidity of 10 % to 60 % at the following ambient temperatures:
Up to one month: -20 °C to +45 °C (-4 °F to +113 °F)
Up to 3 months: -10 °C to +35 °C (+14 °F to +95 °F)
Over 3 months: -10 °C to +25 °C (+14 °F to +77 °F)
UKUVUSELELA
ISAZISO
Ukulahlwa okungalungile kwemikhiqizo kagesi, amabhethri nezinto zokupakisha kubeka imvelo engcupheni. Sicela uqaphele okulandelayo lapho ulahla izinto:
UNGAwalahli amabhethri anemfucuza yasendlini.
Hlala ulahla imikhiqizo kagesi, amabhethri nezinto zokupakisha ezindaweni ezifanele zokuqoqa. Ngale ndlela, uvimbela ukulahlwa kukadoti okungalawuleki futhi ukhuthaze ukugaywa kabusha kwezinsizakusebenza.
You can obtain further information from regional waste disposal companies, state authorities or the i.safe MOBILE GmbH service centre responsible for your country or region at www.isafe-mobile.com/en/support/service
AMAKHI
i.safe MOBILE GmbH kanye nelogo ye-i.safe MOBILE GmbH izimpawu zokuthengisa ezibhalisiwe ze-i.safe MOBILE GmbH. Zonke ezinye izimpawu zokuthengisa namalungelo okushicilela kuyimpahla yabanikazi bazo.

CONTACT/SERVICE CENTRE
EMINYE IMIBUZO SICELA UTHINTE NESIKHUNGO SETHU SEZINKONZO:
i.safe MOBILE GmbH, i_Park Tauberfranken 10, 97922 Lauda-Koenigshofen, Germany
support@isafe-mobile.com
https://support.isafe-mobile.com
ISAFE-MOBILE.COM
Amadokhumenti / Izinsiza
![]() |
i safe MOBILE MIM1xA01 Interface Module [pdf] Incwadi Yeziqondiso IS-IM1x.1, MIM1xA01, MIM1xA01 Interface Module, MIM1xA01, Interface Module, Module |