I-EPH CONTROLS TR1V2-TR2V2 RF Mains switch

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-product

Imininingwane

  • Ukunikezwa kwamandla kagesi: 200 – 240VAC 50-60Hz
  • Isilinganiso sothintana naye: 230 Vac 10(3)A
  • Izinga lokushisa le-ambient: 0…45˚C
  • Isenzo esizenzakalelayo: Type 1. C.
  • Amakilasi kagesi: Isisetshenziswa sikagesi seClass IIEPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-1
  • Iziqu zokungcola: Idigri yokungcola 2
  • Isilinganiso se-IP: IP20
  • Kukalwe Impulse Voltage: Ukumelana ne-voltage-surge 2500V njenge-EN 60730 ngayinye

Isebenza kanjani i-TR1 TR2V2 yakho

  • Your TR1 TR2V2 is used to send a wireless signal from one location to another when running Cables is difficult, expensive, or otherwise not an option.
  • The product comprises two devices: a TR1V2 and a TR2V2. Both devices are pre-paired during manufacturing for user convenience.
  • When 230V is applied to the Live in terminal of the TR1V2, the COM and Live out connection closes, which sends voltage from Live out on the TR2V2.
  • It is possible to send a wireless signal in one direction or both.
  • When a signal is sent from the TR1V2 to the TR2V2, a green light will activate on the TR2V2.
  • When the TR2V2 sends a signal to the TR1V2, a green light will activate on the TR1V2.
  • Common uses include sending a signal from a programmer to a boiler or hot water cylinder that is in a different location. These are also used to control pump overrun and many other applications.
  • It is possible to have more than one set of TR1, TR2V, 2and, where required.
  • Please see pages 9-13 for wiring exampLes

Umdwebo wezintambo wangaphakathi we-TR1TR2V2

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-2ISEXWAYISO: Installation should only be carried out by a qualified person and by wiring regulations.

Switching  Options

Ukushintsha Okuyinhloko

  • Link L to 3

I-Vol ephansitage Ukushintsha

  • Remove the external controls link from the boiler PCB.
  • Connect 2 and 3 to these terminals.

Ukukhweza & Ukufakwa

  1. The TRIV2 should be wall-mounted in an area within 30 metres of the TR2V2. Both TRIV2 & TR2V2 must be mounted more than 25cm away from metal objects, as this will affect communication. The TRIV2 & TR2V2 should be installed at least 1 metre from any electronic devices such as radio, TV, microwave, ve, or wireless network adapter. They can be fitted to
    1. Single-gang recessed back box.
    2. Amabhokisi okukhweza ebusweni
    3. Directly mounted on a wall.
  2. Use a Phillips screwdriver to loosen the screws of the backplate on the bottom of the TRIV2 & TR2V2, lift upwards from the bottom, and remove the backplate.
  3. Screw the backplate to the wall with the screws provided.
  4. Faka i-backplate ngocingo njengomdwebo wezintambo.
  5. Mount the TRIV2 & TR2V2 on the backplate, making sure the pins and the backplatcontactsts are making a sound connection. Push the TRIV2 & TR2V2 flush to the surface and tighten the screws of the backplate from the bottom.m

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-3EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-4

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-5

Inkinobho / Incazelo ye-LED

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-6

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-7Imanuwali Press to activate or deactivate the Live out terminal.
EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8Xhuma Hold for 3 seconds to initialise the pairing process. The RF light will flash.
EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-9Setha kabusha Press to reset the T, R1, TR2V2.
Qaphela: The connection procedure is not required as both TR1 & TR2V2 are pre-paired

Incazelo ye-LED

I-LED Umbala Incazelo
Phila ku-LED Okubomvu Akukho voltage on the Live terminal.
Okuhlaza Kukhona voltage-Live in terminal - Manje isignali ye-RF izothunyelwa kwenye i-RF Mains Switch ukuze uvule itheminali ye-Live out.
I-RF ye-RF Emhlophe I-Solid White LED ekhombisa ukuthi i-thermostat ixhunyiwe.
Isibani se-RF sizokhanyisa kabili lapho i-thermostat inqanyulwa. Hlola ukumataniswa kwe-thermostat.
             Qaphela: Isibani se-RF sizocwayiza njalo lapho isistimu ithumela futhi ithola isignali yokuxhumana.
            Qaphela: The RF light will blink once every second when in RF pairing by holding Connect. Press the Manual to exit from this state.
Phila ngaphandle kwe-LED Okubomvu Akuzange kube khona isignali yokusebenzisa i-RF etholwe kwenye I-RF Mains Switch.
Okuhlaza RF activation signal has been received from the other RF Mains Switch.

To connect the TRI TR2V2
Ngicela uqaphele: When installing TRI TR2V2 RF mains switches, both TRI &TR2V2 are pre-paired. The procedures below are not required.

On TR1V2:

  • Bamba EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 3 seconds until the RF LED flashes white.

On TR2V2:

  • Bamba EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8imizuzwana emi-3.
  • The RF LED will begin to flash, and the Live out LED will appear solid green.
  • When connected, all three LEDs will appear solid.

On TR1V2:

  • Cindezela inkinobho EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-7to exit the pairing mode.
  • After connecting successfully, the RF LED on both TR1V2 & TR2V2will appear solid.

To disconnect the TRI TR2V2

  • Bamba EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 3 seconds until the RF LED flashes white.
  • Bamba EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 10 seconds until the Live in LED appears solid red.

On TR2V2:

  • Bamba EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8for 3 seconds until the RF LED flashes white.
  • Bamba EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-8Connect for 10 seconds until the Live in & Live out LED appears solid red.

On TRIV2:

  • Cindezela EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-7ukuphuma.
  • The TRI TR2V2 is now disconnected.

Izintambo ExampLes

Example  One way RF Switch: Programmer to Boiler – Mains Switching

I-TR1V2 
On TR1, when Live in receives 230V from the programmer, TR1 sends a wireless signal to TR2.

I-TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the boiler.EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-11

Amanothi okufaka

  1. Mains Switching Boiler
  2. I-Low-Voltage Switching Boiler
  • Idatha ye-TR2V2
  • On the boiler PCB
  • Idatha ye-TR2V2
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.

Example 2 Two Two-way RF Switch:

  1. Programmer to Motorised Valve
  2. Motorised Valve to Boiler – Mains Switching

T RI v2

  • On TRI
    When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2.
  • On TRI
    Live out contact closes, sending 230V to activate the boiler.

I-TR2V2
On TR2, the COM & Live out contact closes, sending 230V to activate the motorised valve. When the valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-12

Amanothi okufaka

1. Main Switching Boiler
2. I-Vol-Lowtage Switching Boiler
3. I-Motorized Valve

  • On the TRIV2
  • On the boiler PCB
  • On the TRIV2
  • Idatha ye-TR2V2
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
  • Link L to 3 to power the Live out terminal to the motorised valve.

Example 3 One way RF Switch:
Pump Overrun – Mains Switching

TR 1 v2

  • On TRI, when Live in receives 230V from the boiler, TRI sends a wireless signal to TR2.

I-TR2V2

On TR2, the COM & Live out contact closes, sending 230V to activate the pump.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-13

Inothi Lokufaka

  • Phakamisa
  • the TR2V2
  • Link L to 3 to power the Live out terminal to the pump

Example 4 Two Two-way RF Switch: Pump Overrun

  1. Uhlelo ku-Boiler
  2. Boiler to Pump – Mains Switching

T RI v2

  • On TRI
    When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2.
  • On TRI
    Live out contact closes, sending 230V to activate the pump.

I-TR2V2

  • On TR2, the COM & Live out contact closes, sending 230V to activate the boiler. When the boiler turns off, the pump overrun activates, sending 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-14Inothi Lokufaka

  1. Mains Switching Boiler
  2. I-Low-Voltage Switching Boiler
  3. Iphampu
  • Idatha ye-TR2V2
  • On the boiler PCB –
  • Idatha ye-TR2V2
  • On the TRIV2
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
  • Link L to 3 to power the Live out terminal to the pump.

Example 5 Two Two-way RF Switch: Unvented Cylinder:

  1. I-Programmer to High Limit Thermostat
  2. Motorised Valve to Boiler – Mains Switching

T RI v2

  • On TRI
    When Live in receives 230V from the programmer, TRI sends a wireless signal to TR2.
  • On TRI
    Live out the contact closes, sending 230V to activate the boiler.

I-TR2V2

On TR2, the COM & Live out contact closes, sending 230V to the high limit thermostat, powering the brown cable of the motorised valve. When the motorised valve auxiliary switch engages, it sends 230V to the Live in contact. TR2 then sends a wireless signal to TRI.

EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-15Amanothi okufaka

  1. Mains Switching Boiler
  2. I-Low-Voltage Switching Boiler
  3. I-Thermostat enomkhawulo ophezulu
  4. I-Motorized Valve
  • On the TRIV2
  • On the boiler PCB
  • Idatha ye-TR2V2
  • Link L to 3.
  • Remove the external controls link.
  • Connect terminals 2 & 3 to the external controls terminals on the boiler PCB.
  • Link L to 3 to power the Live out terminal to the High Limit thermostat.

I-EPH Ilawula i-IE
technical@ephcontrols.com
www.ephcontrols.com/contact-us
+353 21 471 8440
cork, Tl 2 W665EPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-16

I-EPH Ilawula i-UK
technical@ephcontrols.co.uk
www.ephcontrols.co.uk/
Xhumana nathi
+44 1933 322 072
Harrow, HAI IBDEPH-CONTROLS-TR1V2-TR2V2-RF-Mains-Switch-fig-17

Imibuzo Evame Ukubuzwa

Q: Can I install the TR1, TR2V2V2 devices myself?
A: Installation should only be carried out by a qualified person following wiring regulations to ensure safety and proper functionality.

Q: Iliphi ibanga elikhulu phakathi kwe-TR1V2 ne-TR2V2 ukuze kuxhunyanwe ngempumelelo?
A: The recommended distance is within 30 meters for optimal wireless signal transmission.