I-DUCO L2003592-F Modbus TCP

Imininingwane Yomkhiqizo
- Igama Lomkhiqizo: Ibhodi Lokuxhumana le-Duco
- Amamodeli Asekelwe: DucoBox Silent Connect, DucoBox Focus, DucoBox Energy
- Modbus Subset Support: HEX 0x03, 0x04, 0x06, 0x10
- Modbus Component Interface: TCP on port 502
Imiyalo yokusetshenziswa komkhiqizo
Ukusebenza namarejista/amapharamitha
The DucoBox Silent Connect, Focus, and Energy support the following Modbus subset functions:
- Funda amarejista amaningi okubambile (HEX 0x03)
- Funda amarejista amaningi we-INPUT (HEX 0x04)
- Write a single HOLDING register (HEX 0x06)
- Bhala amarejista amaningi okubambile (HEX 0x10)
Input registers are read-only 16-bit variables, while holding registers are read/write 16-bit variables. The Modbus address can be set via the Display menu, Duco Installation App, or Duco Network Tool.
Ukuxhumana ne-Control Unit
The external control unit communicates with each component through read parameters (INPUT) and write parameters (HOLDING).
- Funda Amapharamitha (INPUT): Ventilation system type, ventilation status, indoor air quality based on relative humidity, indoor air quality based on CO2 value, etc.
- Bhala Amapharamitha (HOLDING): Ventilation status, component identification, etc.
It is recommended to read the current value before performing a write action to adjust the value. There are limits on write actions to prevent excessive writing.
Kuphelileview ye-Parameters
Ngezansi i-overview of the INPUT and HOLDING parameters for the ventilation system and its components:
| Bhalisa | INPUT (Funda ipharamitha) | Ukuguqulwa Kwedatha | Isicelo | Imvamisa Yenhlolovo Enconyiwe |
|---|---|---|---|---|
| 0020 | Izinga lokushisa ODA | Ibonisa izinga lokushisa lomoya wokuhlinzeka kusuka ngaphandle kuya ku iyunithi (Umoya Wangaphandle). |
I-DucoBox Amandla | 1/min |
Isingeniso
- The Modbus interface on DUCO systems (via the Duco Connectivity Board option on a DucoBox)1 allows an external controller or building management system to communicate with the DUCO ventilation system.
- That way, you can retrieve info about the ventilation network via read parameters or input registers, or read or adjust settings via write parameters or holding registers.
- The supported protocol is Modbus TCP over Ethernet or Wi-Fi via the Duco Connectivity Board. The information in this document is valid from API version v2.5 onwards.
Working registers/parameters
- The DucoBox Silent Connect, Focus, and Energy support the following Modbus subset:
I-HEX DEC SUPPORT FUNCTION 0x03 3 Funda amarejista amaningi okubaMBA 0x04 4 Funda amarejista amaningi we-INPUT 0x06 6 Write a single HOLDING register 0x10 16 Write multiple HOLDING registers - Here, input registers are 16-bit read-only variables, and holding registers are 16-bit read/write variables. Combined consecutive registers are not used. The Duco Connectivity Board functions as a Modbus component via TCP on port 502. The Modbus address can be set via the Display menu (see information sheet L8000002), the Duco Installation App, or the Duco Network Tool.
- The external control unit communicates with each component (node) through read parameters (INPUT) and write parameters (HOLDING).
- Read parameters (INPUT): ventilation system type, ventilation status, indoor air quality based on relative humidity, indoor air quality based on CO2 value, …
- Write parameters (HOLDING): ventilation status, identification (of components), …
Qaphela: Read parameters can be read without restriction. There are, however, two important limits to writing actions:- A daily limit of 200 write actions. From a second supply or extraction zone, 100 write actions are added per additional zone.
- A periodic limit of one write action every 2 seconds.
- It is recommended to use a logic that first reads the current value before determining whether a new write action is needed to adjust the value.
- Indawo ngayinye nemingcele yayo yabelwe ikhodi: XXyy (XX=inombolo yenodi, yy=inombolo yepharamitha).

- This allows all values to be read and controlled from the external control unit. There are specific parameters for each component.
Qaphela- Due to a difference in some Modbus implementations compared to the official specification (on which our implementation is based), an address shift of ‘1’ may occur for the read and write parameters.
E.g.: read address ‘20’ will become ‘19’. - For any box type (Silent Connect, Focus, Energy), this can be resolved via the Duco Installation App or the Duco Network Tool under tab > Tree view-Settings-external settings. With the DucoBox Focus, moreover, this can be solved by setting ‘ > ‘RegOffs’ to ‘1’ under > CONFIG > Modbus in the Display menu. With the DucoBox Energy also possible via ‘Register Offset’ under > Setting > Modbus in the advanced menu.
- Due to a difference in some Modbus implementations compared to the official specification (on which our implementation is based), an address shift of ‘1’ may occur for the read and write parameters.
Kuphelileview kwamapharamitha
The overview is grouped into three sections:
- Parameters that are only supported at the system level.
- Parameters that are only supported by the DucoBox.
- Parameters that are supported by the nodes (components).
Ngezansi i-overview we-INPUT kanye nemingcele yokubamba kokubili isistimu yokukhipha umoya kanye nezingxenye.
Amapharamitha wesistimu:
| INPUT
(funda ipharamitha) |
||||
| Bhalisa | Idatha | Ukuguqulwa | Isicelo | Imvamisa yohlolo olunconyiwe |
| 0020 | Izinga lokushisa ODA Displays the temperature of the supply air from outside to the unit (Outdawu Air). | °C / 10 | I-DucoBox Amandla | 1 / iminithi |
| 0021 | SUP temperature displays the temperature of the supply air from the unit to the home (Supply Air). | °C / 10 | I-DucoBox Amandla | 1 / iminithi |
| 0022 | Izinga lokushisa I-ETA Displays the temperature of the exhaust air from the home to the unit (Extract Air). | °C / 10 | I-DucoBox Amandla | 1 / iminithi |
| 0023 | Izinga lokushisa EHA Displays the temperature of the exhaust air from the unit to the outside (Exhaust Air). | °C / 10 | I-DucoBox Amandla | 1 / iminithi |
| 0024 | Izinga lokushisa langaphandle measured via the weather station. | °C / 10 | I-DucoBox enesiteshi sezulu | 1 / iminithi |
| 0025 | Isivinini somoya Measured via the weather station. |
Idesimetha/yesibili | I-DucoBox enesiteshi sezulu | 1 / iminithi |
| 0026 | Imvula Measured via the weather station. |
0 = Cha (Amanga) 1 = Yebo (Iqiniso) | I-DucoBox enesiteshi sezulu | 1 / iminithi |
| 0027 | Light intensity south was measured via the weather station. | I-Kilolux | I-DucoBox enesiteshi sezulu | 1 / iminithi |
| 0028 | Light intensity east was measured via the weather station. | I-Kilolux | I-DucoBox enesiteshi sezulu | 1 / iminithi |
| 0029 | Light intensity west was measured via the weather station. | I-Kilolux | I-DucoBox enesiteshi sezulu | 1 / iminithi |
| 0030 | Local API Version Displays the local API version. | Inombolo ephelele Example: 2.4 becomes 204.
Public API version ‘X.Y’ becomes Modbus = X · 100 + Y |
DucoBox Silent Connect DucoBox Focus DucoBox Energy | 1 / ngosuku |
| 0031 | Remaining write actions: Displays the number of corrective commands until midnight. | Inombolo ephelele | DucoBox Silent Connect DucoBox Focus DucoBox Energy | 1 / iminithi |
- Negative temperatures are displayed as a number greater than 32767.
- To display this value correctly, you need to implement some logic to convert the value.
- The formula is: (value-65536)/ 10
- Example:
- If(ModBusInputRegisterValue >= 32768)
- Temp = (ModbusInputRegisterValue – 65536)/10
Okunye - Temp = ModbusInputRegisterValue/10
Qeda
Amapharamitha we-DucoBox:
| INPUT
(funda ipharamitha) |
|||||
| Bhalisa | Idatha | Ukuguqulwa | Isicelo | Imvamisa yohlolo olunconyiwe | |
| 0100 | Uhlobo lwesistimu Indicates the type of ventilation system |
17 = DucoBox | DucoBox Silent Connect DucoBox Focus DucoBox Energy | isikhathi esisodwa | |
| 0102 | Isikhathi esisele Imodi yamanje Yokungenisa umoya Ibonisa isikhathi esisele lapho i-DucoBox izokhipha umoya ngayo kule modi |
Imizuzwana | DucoBox Silent Connect DucoBox Focus DucoBox Energy | 1 / iminithi | |
| 0103 | Izinga lokugeleza liqhathaniswa neleveli eqondiwe Ibonisa imodi yokungenisa umoya yangempela yezoni lapho ingxenye etholakala khona |
Iphesentitage | DucoBox Silent Connect DucoBox Focus DucoBox Energy | 1 / iminithi | |
| 0104 | Ikhwalithi yomoya wasendlini esekelwe ku-RH Average indoor air quality based on measured relative humidity |
100 %
95 % |
Ikhwalithi yomoya yasendlini enhle kakhulu | Box sensor DucoBox Silent Connect
Box sensor DucoBox Energy |
1 / iminithi |
| 90 %
80 % 65 % |
Ikhwalithi yomoya yasendlini enhle | ||||
| 50 %
35 % |
Ikhwalithi yomoya yasendlini eyamukelekayo okwesikhashana | ||||
| 20 %
5 % |
Ikhwalithi yomoya yasendlini ephansi | ||||
| 0105 | Indoor air quality based on CO2 Average indoor air quality based on measured CO2 value |
100 % Very good indoor air 95 % quality
90 % |
Box sensor DucoBox Silent Connect
Box sensor DucoBox Energy |
1 / iminithi | |
| 85 %
80 % Good indoor air quality 75 % |
|||||
| 70 %
65 % Temporarily acceptable 60 % indoor air quality 55 % 50 % |
|||||
| 45 %
40 % Poor indoor air quality 35 % 35 % |
|||||
| 0106 | Ventilation status Indicates the status of ventilation |
0 = KULUNGILE 1 = Iphutha 2 = Ayisebenzi |
DucoBox Silent Connect DucoBox Focus DucoBox Energy | 1 / iminithi | |
| 0107 | Filter Time Remaining Indicates remaining filter life |
Izinsuku | I-DucoBox Amandla | 1 / ngosuku | |
| 0108 |
Hlunga isimo |
0 = KULUNGILE
1 = Filter is dirty 2 = Inactive |
I-DucoBox Amandla | 1 / iminithi | |
| 0109 | Umswakama Indicates the measured humidity value. |
I-RH (%) (umswakama ohlobene) | DucoBox Silent Connect DucoBox Focus DucoBox Energy
+ minimum 1 humidity sensor |
1 / iminithi | |
| 10 % | Ikhwalithi yomoya yasendlini ephansi | ||||
| 15 % | |||||
| 20 % Temporarily acceptable | |||||
| 25 % indoor air quality | |||||
| 30 % | Ikhwalithi yomoya yasendlini enhle | ||||
| 35 % | |||||
| 40 % | |||||
| Ikhwalithi yomoya yasendlini enhle kakhulu | |||||
| 45 %
50 % 55 % |
|||||
| 60 % | Ikhwalithi yomoya yasendlini enhle | ||||
| 65 % | |||||
| 70 % | |||||
| 75 % Temporarily acceptable | |||||
| 80 % indoor air quality | |||||
| 85 % | Ikhwalithi yomoya yasendlini ephansi | ||||
| 0110 | CO2 Indicates the measured CO2 value. |
I-CO2 (ppm) | DucoBox Silent Connect DucoBox Focus DucoBox Energy
+ ubuncane benzwa ye-CO2 engu-1 |
1 / iminithi | |
| <800
800 900 |
Ikhwalithi yomoya yasendlini enhle kakhulu | ||||
| 1000
1100 1200 |
Ikhwalithi yomoya yasendlini enhle | ||||
| 1250
1300 1350 1400 1450 |
Ikhwalithi yomoya yasendlini eyamukelekayo okwesikhashana | ||||
| 1500
1550 1600 > 1600 |
Ikhwalithi yomoya yasendlini ephansi | ||||
| UKUBAMBA
(read/write parameter) |
||||
| Bhalisa | Idatha | Ukuguqulwa | Isicelo | Imvamisa yohlolo olunconyiwe |
| 0100 | Imodi yokungenisa umoya
Here, the ventilation mode can be adjusted. Conversions 11 through 16 are used to maintain manual modes longer. Okwesiboneloample, Manual 1 (conversion 4) is set to duration t by default. For Manual 1 x 2 (conversion 11), the mode t x 2 (= 2 x standard duration) will be maintained and for Manual 1 x 3 (conversion 14), the mode t x 3 (= 3 x standard duration) will be maintained. |
0 = NGOKUZENZAKALELAYO
4 = Manual 1 5 = Manual 2 6 = Manual 3 7 = Not at home 8 = Permanent 1 9 = Permanent 2 10 = Permanent 3 11 = Manual 1 x 2 12 = Manual 2 x 2 13 = Manual 3 x 2 14 = Manual 1 x 3 15 = Manual 2 x 3 16 = Manual 3 x 3 |
DucoBox Silent Connect DucoBox Focus DucoBox Energy | 1 / iminithi |
| xx01 | Ukuhlonza: Here, a component can be identified. This will light up blue. | 0 = Ukubonakala Kwenodi KUVALIWE 1= Ukubona Ngeso leNodi KUVULIWE | DucoBox Silent Connect DucoBox Focus DucoBox Energy | One-time, read before write. (Read and check before writing) |
| 0102 | Izinga lokushisa lokunikezela target zone 1 Lapha, izinga lokushisa lokunethezeka le-SUP zone 1 lingalungiswa |
°C / 10 | I-DucoBox Amandla | One-time, read before write. (Read and check before writing) |
| 0103 | Izinga lokushisa lokunikezela target zone 2 Lapha, izinga lokushisa lokunethezeka le-SUP zone 2 lingalungiswa |
°C / 10 | I-DucoBox Amandla | One-time, read before write. (Read and check before writing) |
| 0104 | Izinga lokushisa lokunikezela target zone 3 Lapha, izinga lokushisa lokunethezeka le-SUP zone 3 lingalungiswa |
°C / 10 | I-DucoBox Amandla | One-time, read before write. (Read and check before writing) |
| 0105 | Izinga lokushisa lokunikezela target zone 4 Lapha, izinga lokushisa lokunethezeka le-SUP zone 4 lingalungiswa |
°C / 10 | I-DucoBox Amandla | One-time, read before write. (Read and check before writing) |
Amapharamitha weNode:
| INPUT
(funda ipharamitha) |
||||
| Bhalisa | Idatha | Ukuguqulwa | Isicelo | Imvamisa yohlolo olunconyiwe |
| xx00 | Uhlobo lwesistimu Indicates the type of ventilation system |
0 = Akwaziwa
7 = DucoTronic window ventilator 8 = User controller RF/BAT 9 = User controller RF/Wired 10 = Humidity Room sensor 12 =CO2 Room sensor 13 = Sensorless Control Valve 14 = Humidity Control Valve 16 = CO2 Control Valve 18 = Switch Sensor 22 = iAV Control valve 23 = iAV Humidity 25 = iAV CO2 27 = Iyunithi yokulawula 28 =CO2/RH control valve 29 = User Controller ‘Sun Control’ 30 = User Controller ‘Ventilative Cooling’ 31 = External multi-zone valve 35 = Humidity box sensor 37 = CO2 Box Sensor 38 = Motor relay 39 = Duco Weather Station or Outdoor Temperature Sensor 40 = Modbus motor 41 = Digital input 42 = Digital output 44 = Modbus relay 45 = Perilex 46 = Relay output |
User controller Room sensor Box sensor Control valve Switch sensor
I-electronic window ventilator |
isikhathi esisodwa |
| xx02 | Isikhathi esisele Imodi yamanje Yokungenisa umoya Ibonisa isikhathi esisele lapho i-DucoBox izokhipha umoya ngayo kule modi |
Imizuzwana | Isilawuli somsebenzisi Inzwa yegumbi Control valve Shintsha inzwa | 1 / iminithi |
| xx03 | Izinga lokugeleza liqhathaniswa neleveli eqondiwe Ibonisa imodi yokungenisa umoya yangempela yezoni lapho ingxenye etholakala khona |
Iphesentitage | Control valve, Electronic window ventilator | 1 / iminithi |
| xx04 | Ikhwalithi yomoya wasendlini esekelwe ku-RH Average indoor air quality based on measured relative humidity |
100 %
95 % |
Ikhwalithi yomoya yasendlini enhle kakhulu | I-valve yokulawula inzwa yegumbi | 1 / iminithi |
| 90 %
80 % 65 % |
Ikhwalithi yomoya yasendlini enhle | ||||
| 50 %
35 % |
Ikhwalithi yomoya yasendlini eyamukelekayo okwesikhashana | ||||
| 20 % | Ikhwalithi yomoya yasendlini ephansi | ||||
| xx05 | Indoor air quality based on CO2 Average indoor air quality based on measured CO2 value |
100 % Very good indoor air 95 % quality
90 % |
I-valve yokulawula inzwa yegumbi | 1 / iminithi | |
| 85 %
80 % Good indoor air quality 75 % |
|||||
| 70 %
65 % Temporarily acceptable 60 % indoor air quality 55 % 50 % |
|||||
| 45 %
40 % Poor indoor air quality 35 % 30 % |
|||||
| xx09 | Umswakama Indicates the measured humidity value. |
I-RH (%) (umswakama ohlobene) | Humidity Room Sensor Humidity Box Sensor
Ivalvu Yokulawula Umswakama I-electronic window ventilator |
1 / iminithi | |
| 10 %
15 % |
Ikhwalithi yomoya yasendlini ephansi | ||||
| 20 %
25 % |
Ikhwalithi yomoya yasendlini eyamukelekayo okwesikhashana | ||||
| 30 %
35 % 40 % |
Ikhwalithi yomoya yasendlini enhle | ||||
| 45 %
50 % 55 % |
Ikhwalithi yomoya yasendlini enhle kakhulu | ||||
| 60 %
65 % 70 % |
Ikhwalithi yomoya yasendlini enhle | ||||
| 75 %
80 % |
Ikhwalithi yomoya yasendlini eyamukelekayo okwesikhashana | ||||
|
85 % |
Ikhwalithi yomoya yasendlini ephansi | ||||
| xx10 | CO2 Indicates the measured CO2 value. |
I-CO2 (ppm) | I-CO2 Room Sensor CO2 Box Sensor CO2 Control Valve | 1 / iminithi | |
| < 800 Very good indoor air quality 800
900 |
|||||
| 1000 | |||||
| 1100 Good indoor air quality | |||||
| 1200 | |||||
| 1250 | |||||
| 1300 Temporarily acceptable
1350 indoor air quality |
|||||
| 1400 | |||||
| 1450 | |||||
| 1500
1550 1600 > 1600 |
Ikhwalithi yomoya yasendlini ephansi |
||||
| UKUBAMBA
(read/write parameter) |
||||
| Bhalisa | Idatha | Ukuguqulwa | Isicelo | Imvamisa yohlolo olunconyiwe |
| xx00 | Imodi yokungenisa umoya
Here, the ventilation mode can be adjusted. Conversions 11 through 16 are used to maintain manual modes longer. Okwesiboneloample, Manual 1 (conversion 4) is set to duration t by default. For Manual 1 x 2 (conversion 11), the mode t x 2 (= 2 x standard duration) will be maintained and for Manual 1 x 3 (conversion 14), the mode t x 3 (= 3 x standard duration) will be maintained. |
0 = NGOKUZENZAKALELAYO
4 = Manual 1 5 = Manual 2 6 = Manual 3 7 = Not at home 8 = Permanent 1 9 = Permanent 2 10 = Permanent 3 11 = Manual 1 x 2 12 = Manual 2 x 2 13 = Manual 3 x 2 14 = Manual 1 x 3 15 = Manual 2 x 3 16 = Manual 3 x 3 |
User controller Room sensor Box sensor Control valve
I-electronic window ventilator |
1 / iminithi |
| xx01 | Ukuhlonza Here, a component can be identified. This will light up blue. |
0 = Ukubonakala Kwenodi KUVALIWE 1= Ukubona Ngeso leNodi KUVULIWE | User controller, Room sensor, Control valve,e Switch sens, or Electronic window ventilator | One-time, read before write. (Read and check before writing it) |
Imininingwane ejwayelekile
Ukuze uthole ukuthi yimaphi ama-node akhona kunethiwekhi, ungakwazi (ngokuzithandela) ukusebenzisa amarejista we-INPUT angezansi. Ngaphandle kwalokho, ungaskena wonke amarejista.
Example:

|
BHALISA |
IDATHA |
OKUNCONYWA KWE-SURVEY FREQUENCY |
| 0000 | Bit field indicating which node numbers between 1 and 15 are occupied in the network |
isikhathi esisodwa |
| 0001 | Bit field indicating which node numbers between 16 and 31 are occupied in the network | |
| 0002 | Bit field indicating which node numbers between 16 and 31 are occupied in the network | |
| 0003 | Bit field indicating which node numbers between 48 and 63 are occupied in the network | |
| 0004 | Bit field indicating which node numbers between 64 and 79 are occupied in the network | |
| 0005 | Bit field indicating which node numbers between 80 and 95 are occupied in the network | |
| 0006 | Bit field indicating which node numbers between 96 and 111 are occupied in the network | |
| 0007 | Bit field indicating which node numbers between 112 and 127 are occupied in the network | |
| 0008 | Bit field indicating which node numbers between 128 and 143 are occupied in the network |
imibuzo ejwayelekile ukubuzwa
How can I set the Modbus address for the Duco Connectivity Board?
The Modbus address can be set via the Display menu, Duco Installation App, or Duco Network Tool.
What are the limits on write actions for the Duco Connectivity Board?
There is a daily limit of 200 write actions, with additional actions allowed based on the number of supply or extraction zones. Additionally, there is a periodic limit of one write action every 2 seconds.
Amadokhumenti / Izinsiza
![]() |
I-DUCO L2003592-F Modbus TCP [pdf] Incwadi Yeziqondiso I-Silent Connect, Focus, Energy, L2003592-F Modbus TCP, L2003592-F, Modbus TCP, TCP |