DAUDIN-LOGO

I-DAUDIN GFGW-RM01N HMI Modbus TCP Connection

I-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-PRODUCT

Ulwazi Lomkhiqizo

Umkhiqizo uwuhlu lokucushwa kwemojuli ye-I/O ekude
kuhlanganisa izingxenye ezihlukahlukene:

Ingxenye No. Ukucaciswa
I-GFGW-RM01N I-Modbus TCP-to-Modbus RTU/ASCII, 4 Ports
I-GFMS-RM01S I-Master Modbus RTU, 1 Port
I-GFDI-RM01N Okokufaka Kwedijithali 16 Isiteshi
I-GFDO-RM01N I-Digital Output 16 Channel / 0.5A
I-GFPS-0202 Amandla angu-24V / 48W
I-GFPS-0303 Amandla angu-5V / 20W

Isango lisetshenziswa ngaphandle ukuxhumana ne-Beijer HMI's
imbobo yokuxhumana (i-Modbus TCP). Isilawuli esikhulu sinesibopho
ukuze uphathe futhi ulungiselele ngokuguquguqukayo amapharamitha we-I/O. Amandla
imojuli ingxenye ejwayelekile engakhethwa ngokusekelwe kumsebenzisi
okuthandayo.

Imiyalo yokusetshenziswa komkhiqizo

Ukuze uxhume ku-Beijer HMI, landela lezi zinyathelo:

  1. Qinisekisa ukuthi imojuli inikwe amandla futhi ixhunywe kumojula yesango usebenzisa intambo ye-Ethernet.
  2. Yethula isofthiwe ye-i-Designer.
  3. Khetha "Ukucushwa Kwemoduli ye-M Series".
  4. Chofoza kusithonjana "Setting Module".
  5. Faka ikhasi elithi “Imojuli yokusetha” lochungechunge lwe-M.
  6. Khetha uhlobo lwemodi ngokusekelwe kumojuli exhunyiwe.
  7. Chofoza "Xhuma".
  8. Lungiselela Izilungiselelo Ze-IP Yemojuli Yesango (Qaphela: Ikheli lasesizindeni se-inthanethi kufanele libe kusizinda esifanayo nesempahla yesilawuli).
  9. Setha Iqembu 1 Njengesigqila futhi usethe isango lokusebenzisa isethi yokuqala yezimbobo ze-RS485 ukuze uxhume kusilawuli esikhulu (GFMS-RM01N).

Uhlu Lokucushwa Kwemojuli ye-I/O yesilawuli kude

Ingxenye No. Ukucaciswa Incazelo
I-GFGW-RM01N I-Modbus TCP-to-Modbus RTU/ASCII, 4 Ports Isango
I-GFMS-RM01S I-Master Modbus RTU, 1 Port Isilawuli Esiyinhloko
I-GFDI-RM01N Okokufaka Kwedijithali 16 Isiteshi Okokufaka kwedijithali
I-GFDO-RM01N I-Digital Output 16 Channel / 0.5A Ukukhishwa Kwedijithali
I-GFPS-0202 Amandla angu-24V / 48W Ukunikezwa kwamandla kagesi
I-GFPS-0303 Amandla angu-5V / 20W Ukunikezwa kwamandla kagesi

Incazelo Yomkhiqizo

  1. Isango lisetshenziswa ngaphandle ukuxhumana ne-Beijer HMI's communication port (Modbus TCP)
  2. Isilawuli esiyinhloko siphethe ukuphathwa nokucushwa okuguquguqukayo kwamapharamitha we-I/O nokunye.
  3. Imojuli yamandla ijwayelekile kuma-I/O akude futhi abasebenzisi bangakhetha imodeli noma uhlobo lwemojuli yamandla abayithandayo.

Izilungiselelo zepharamitha yesango

Lesi sigaba sinemininingwane yokuthi ungaxhuma kanjani ku-Beijer HMI. Ukuze uthole ulwazi oluningiliziwe, sicela ubheke i-iO-GRID M Series Product Manual

Ukusethwa kohlelo lwe-i-Designer

  1. Qiniseka ukuthi imojuli inikwe amandla futhi ixhunywe kumojula yesango usebenzisa ikhebula ye-EthernetI-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (1)
  2. Chofoza ukuze uqalise isofthiweI-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (2)
  3. Khetha okuthi “M Series Module Configuration”I-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (3)
  4. Chofoza kusithonjana "Setting Module".I-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (4)
  5. Faka ikhasi elithi “Imojuli yokusetha” lochungechunge lwe-MI-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (5)
  6. Khetha uhlobo lwemodi ngokusekelwe kumojuli exhunyiweI-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (6)
  7. Chofoza okuthi "Xhuma"I-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (7)
  8. Izilungiselelo ze-IP zemojuli yesangoI-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (8)
    • Qaphela: Ikheli le-IP kufanele libe kusizinda esifanayo nesemishini yesilawuli
  9. Izindlela Zokusebenza Zemojuli YesangoI-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (8)
  10. Qaphela: Setha Iqembu 1 Njengesigqila futhi usethe isango ukuze usebenzise isethi yokuqala yembobo ye-RS485 ukuze uxhume kusilawuli esikhulu (GFMS-RM01N)

Isethaphu yokuxhuma kwe-Beijer HMI
Lesi sahluko sichaza indlela yokusebenzisa uhlelo lukanjiniyela we-iX ukuze uxhume i-Beijer HMI esangweni futhi wengeze i-I/O eyirimothi. Ukuze uthole ulwazi oluningiliziwe, sicela ubheke ku-iX Developer Manual

I-Beijer HMI Hardware Connection

  1. Imbobo yokuxhuma ingakwesokudla ngezansi komshini. Kukhona i-LAN A ne-LAN BI-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (10)

Ikheli le-IP le-Beijer HMI kanye nokusethwa koxhumano

  1. Uma i-HMI isinikwe amandla, cindezela esikrinini se-HMI ukuze ufake imenyu yesevisi bese uchofoza ku-“IP Settings”.I-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (11)
  2. Chofoza okuthi “Cacisa Ikheli Le-IP” bese usetha “Ikheli Le-IP” esizindeni esifanayo nesizinda sesango kokuthi 192.168.1.XXX.I-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (12)
  3. Yethula i-iX Developer bese ukhetha okuthi “MODICON” kanye “neModbus Master” ukuze wengeze isilawuli esishaI-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (13)
  4. Chofoza kuthebhu ethi “Umlawuli” ukuze ufake ikhasi lokusetha isilawuli. Khetha isilawuli bese uchofoza "Izilungiselelo"I-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (14)
  5. Ukusethwa kwendlela yokuxhumanaI-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (15)
    • Ⓐ Kumenyu yokudonsela phansi ethi “Imodi Yokuxhumana”, khetha okuthi “Ethernet TCP/ IP”
    • Ⓑ Setha inombolo yesiteshi ezenzakalelayo
    • Ⓒ Kumenyu eyehlayo ethi “Modbus protocol”, khetha “RTU”
    • Ⓓ Kumenyu yokudonsela phansi ethi “32-bit World mapping”, khetha u-“Little-endian”
    • Ⓔ Kumenyu yokudonsela phansi ethi “Phoqelela ikhodi yokusebenza 0x10”, khetha okuthi “Vumela”
    • Ⓕ Kusuka kumenyu yokudonsela phansi ethi "Ukushintshaniswa kwezintambo", khetha okuthi "Khubaza"
  6. Chofoza "Iziteshi" bese usetha "Isiteshi" kanye "nekheli le-IP" ngokufanayo nesangoI-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (16)
  7. Chofoza ku-"Tab" ukuze ufake ikhasi lesilungiselelo sethebhu. Okulandelayo, chofoza okuthi “Okusha” bese usetha indawo yerejista yethebhuI-DAUDIN-GFGW-RM01N-HMI-Modbus-TCP-Connection-FIG-1 (17)
    • I-GFDI-RM01N yokuqala ye-iO-GRID M inekheli lokuqala ku-44096
    • I-GFDO-RM01N yokuqala ye-iO-GRID M inekheli lokuqala ku-48192

Amadokhumenti / Izinsiza

I-DAUDIN GFGW-RM01N HMI Modbus TCP Connection [pdf] Incwadi Yeziqondiso
GFGW-RM01N HMI Modbus TCP Connection, GFGW-RM01N, HMI Modbus TCP Connection, Modbus TCP Connection, TCP Connection, Connection

Izithenjwa

Shiya amazwana

Ikheli lakho le-imeyili ngeke lishicilelwe. Izinkambu ezidingekayo zimakiwe *