C E Electronics CE3871-0 Powertool Transceiver Module

Imininingwane
- Product Name: Powertool Transceiver Module CE3871
- Manufacturer: C.E. Electronics, Inc.
- Imodeli: CE3871
- IC: 8507A-CE3871
- Ibanga Lemvamisa: 2.410 GHz – 2.465 GHz
Imiyalo yokusetshenziswa komkhiqizo
- The designated cable in the tool should be plugged into the J1 connector.
- The J2 connector is for development purposes and should remain unconnected.
- Mount the module at least 5mm from the outside edge of the product.
- The module’s operation is automated. Attach it to the tool, power it on, and it will establish communication with the tool.
- It will attempt to wirelessly connect to the previous controller; if not found, it will scan through available channels to find a new controller.
CE3871-0 & CE3871-1 Operation Instructions
Umhlangano
- The designated cable in the tool should be plugged into the J1 connector.
- The J2 connector is used for development and should be left unconnected by the user.
- The module must be mounted at least 5mm from the outside edge of the product.

Ukusebenza
- Module operation is entirely automated.
- Once attached to the tool and powered on, the module will automatically begin communication with the tool and attempt to connect wirelessly to the previous controller.
- If the previous controller cannot be found at power-up, the module will automatically scan through the available channels to find a new controller.
Amafrikhwensi esiteshi
| Isiteshi | Imvamisa (GHz) |
| 1 | 2.410 |
| 2 | 2.415 |
| 3 | 2.420 |
| 4 | 2.425 |
| 5 | 2.430 |
| 6 | 2.435 |
| 7 | 2.440 |
| 8 | 2.445 |
| 9 | 2.450 |
| 10 | 2.455 |
| 11 | 2.460 |
| 12 | 2.465 |
ISITATIMENDE SE-FCC
Ulwazi Lokulawula
I-United States (FCC)
CE3871 Modules comply with Part 15 of the FCC rules and regulations. Compliance with the labeling requirements, FCC notices and antenna usage guidelines is required.
Ukuze ugcwalise Isitifiketi se-FCC, i-OEM kufanele ihambisane nemithethonqubo elandelayo:
- Umdidiyeli wesistimu kufanele aqinisekise ukuthi umbhalo kulebula yangaphandle enikezwe lolu cingo ubekwe ngaphandle komkhiqizo wokugcina.
Izidingo zokulebula ze-OEM
ISEXWAYISO! Njengomkhiqizi Wezinto Zoqobo (i-OEM) kufanele uqinisekise ukuthi izidingo zokulebula ze-FCC ziyahlangatshezwa. Kufanele ufake ilebula ebonakala ngokucacile ngaphandle kwendawo evalekile yomkhiqizo ebonisa okuqukethwe okulandelayo:
Contains FCC ID: O4O-CE3871
Le divayisi ithobela Ingxenye 15 Yemithetho ye-FCC. Ukusebenza kungaphansi kwemibandela emibili elandelayo:
- Le divayisi ingase ingabangeli ukuphazamiseka okuyingozi futhi
- Lolu cingo kufanele lwamukele noma yikuphi ukuphazamiseka okutholiwe, okuhlanganisa ukuphazamiseka okungase kubangele ukusebenza okungafuneki.
Izaziso ze-FCC
KUBALULEKILE: CE3871 Modules have been certified by the FCC for use with other products without any further certification (as per FCC section 2.1091). Modifications not expressly approved by C.E. Electronics could void the user’s authority to operate the equipment.
KUBALULEKILE: OEMs must test the final product to comply with unintentional radiators (FCC section 15.107 & 15.109) before declaring compliance of their final product to Part 15 of the FCC Rules.
KUBALULEKILE: The module has been certified for remote, base, and portable radio applications. If the module will be used for portable applications, the device must have a minimum of 5mm separation from the operator.
Lesi sisetshenziswa sihloliwe futhi satholwa ukuthi sithobela imikhawulo yedivayisi yedijithali Yekilasi B, ngokuvumelana Nengxenye 15 Yemithetho Ye-FCC. Le mikhawulo iklanyelwe ukuhlinzeka ngokuvikeleka okufanele ekuphazanyisweni okuyingozi ekufakweni kwendawo yokuhlala. Lesi sixhobo sikhiqiza, sisebenzise futhi singakhipha amandla efrikhwensi yomsakazo futhi, uma singafakiwe futhi sisetshenziswa ngokuhambisana nemiyalelo, singadala ukuphazamiseka okuyingozi ezokuxhumana ngomsakazo. Nokho, asikho isiqinisekiso sokuthi ukuphazamiseka ngeke kwenzeke ekufakweni okuthile.
Uma lo mshini udala ukuphazamiseka okuyingozi emsakazweni noma ekwamukelweni kwethelevishini, okunganqunywa ngokucisha nokuvula okokusebenza, umsebenzisi uyakhuthazwa ukuthi azame ukulungisa ukuphazamiseka ngesinyathelo esisodwa noma ngaphezulu kwezilandelayo: Hlela kabusha noma uthuthe yamukela uthi, Khulisa ukuhlukana phakathi kwemishini nomamukeli, Xhuma amathuluzi nomamukeli ezitolo kumasekhethi ahlukene, noma Xhumana nomthengisi noma uchwepheshe werediyo/TV onolwazi ukuze uthole usizo.
I-ISED (i-Innovation, Science and Economic Development Canada)
Lolu cingo luqukethe ama-transmitter/abamukeli abakhishiwe kulayisense abathobela ama-RSS akhululwe yi-RSS (ama-RSS) e-Innovation, Science and Economic Development Canada. Ukusebenza kungaphansi kwemibandela emibili elandelayo:
- Le divayisi ingase ingabangeli ukuphazamiseka.
- Lolu cingo kufanele lwamukele noma yikuphi ukuphazamiseka, okuhlanganisa ukuphazamiseka okungase kubangele ukusebenza okungafunwa kocingo.
Izidingo zokulebula
- Labeling requirements for Industry Canada are similar to those of the FCC. A clearly visible label on the outside of the final product enclosure must display the following text:
- Contains Model Powertool Transceiver Module CE3871, IC: 8507A-CE3871
- The integrator is responsible for its product to comply with IC ICES-003 & FCC Part 15, Sub. B – Unintentional Radiators. ICES-003 is the same as FCC Part 15 Sub. B and Industry Canada accept FCC test report or CISPR 22 test report for compliance with ICES-003.
- Modifications not expressly approved by C.E. Electronics could void the user’s authority to operate the equipment.
Firmware Version Identification number (FVIN)
- CE3871 firmware versions are 5.x or 6.x. FVIN is displayed on the controller with which the module is communicating.
CONTACT
- C.E. Electronics, Inc.
- 2107 Industrial Drive
- UBryan, OH 43506
- Ucingo: 419-636-6705
- Ifeksi: 419-636-2516
FAQ
Q: How do I know if the module is connected to a controller?
A: The module will automatically establish a connection with the controller when powered on. You can check for successful connection indicators on the tool or controller interface.
Q: Can I use the J2 connector for any purpose?
A: The J2 connector is intended for development purposes only and should not be connected during normal operation to avoid interference with the module's functionality.
Amadokhumenti / Izinsiza
![]() |
C E Electronics CE3871-0 Powertool Transceiver Module [pdf] Incwadi Yeziqondiso CE3871-0, CE3871-1, CE3871-0 Powertool Transceiver Module, CE3871-0, Powertool Transceiver Module, Transceiver Module, Module |