1. Isingeniso
This manual provides detailed instructions for the installation, operation, and maintenance of the SINOTIMER DDS6619 Din Rail Single Phase Energy Meter. This device is designed for measuring active energy consumption in single-phase AC systems. Please read this manual thoroughly before installation and use to ensure proper function and safety.

Isithombe 1: Ngaphambili view of the SINOTIMER DDS6619 Din Rail Single Phase Energy Meter, showing the LCD display and terminal connections.
2. Ulwazi Lokuphepha
Sicela uqaphele izinyathelo zokuphepha ezilandelayo ukuze uvimbele ukulimala kanye nomonakalo kudivayisi:
- Ukufakwa kufanele kwenziwe kuphela izisebenzi eziqeqeshiwe.
- Ensure the main power supply is disconnected before installation or maintenance.
- Do not operate the meter in environments with excessive moisture, dust, or corrosive gases.
- Verify correct wiring connections according to the provided diagram to avoid damage or malfunction.
- The meter is designed for indoor use only.
- Do not attempt to open or repair the meter yourself. Contact qualified service personnel.
3. Okuqukethwe Kwephakheji
Lapho uvula iphakheji, sicela uqinisekise ukuthi zonke izinto zikhona futhi azilimele:
- 1 x SINOTIMER DDS6619 Din Rail Single Phase Energy Meter
- 1 x Incwadi Yomsebenzisi (le dokhumenti)
4. Izici zomkhiqizo
The DDS6619 energy meter offers a range of features for efficient power monitoring:
- Innovative Dual-Row Display: The top row rotates to show temporary kWh, voltage, current, power, power factor, and frequency. The second row displays total power consumption.
- I-LCD Backlight: Blue LCD HD backlight ensures clear visibility in various lighting conditions.
- Ukunemba Okuphezulu: Class 1.0 meter, utilizing microelectronics and digital processing for reliable energy measurement.
- 6-in-1 Multimeter Functionality: Displays Total Energy (kWh), Temporary Energy (kWh), Voltage (V), Current (A), Power (W), Frequency (Hz), and Power Factor (PF).
- Energy Memory: All electric energy data is automatically stored and memorized upon power loss.
- Setha kabusha Umsebenzi: Temporary kWh data can be reset to zero for specific measurement needs. Total power consumption remains unaffected.
- Idizayini Esebenza Kahle Emkhathini: Standard 36mm width, compatible with universal DIN 35mm guide rails.
- Ukwakhiwa Okuqinile: Made from flame-retardant, high-quality ABS material for impact resistance and long service life.

Image 2: Illustration of the DDS6619 display modes, demonstrating how temporary and total readings for various electrical parameters are shown.
5. Ukusetha nokufakwa
5.1 Ubukhulu
The meter is designed for standard DIN rail mounting. Refer to the dimensions below for proper planning:

Image 3: Dimensional drawing of the DDS6619 meter, indicating its width (36.3mm), height (78.5mm), and depth (65.8mm) for installation planning.
5.2 Ukukhweza
- Ensure the main power supply is turned off at the circuit breaker before proceeding.
- Mount the DDS6619 meter onto a standard 35mm DIN rail in your electrical panel.
- Ensure the meter is securely fastened to prevent movement.
5.3 Umdwebo wezintambo
Follow the wiring diagram carefully. Incorrect wiring can cause damage to the meter or electrical system.

Image 4: Wiring diagram for the DDS6619 meter, illustrating the correct connections for live (L) and neutral (N) input and output terminals.
- Connect the incoming Live (L) wire to the terminal marked 'L' on the input side.
- Connect the incoming Neutral (N) wire to the terminal marked 'N' on the input side.
- Connect the outgoing Live (L) wire to the terminal marked 'L' on the output side.
- Connect the outgoing Neutral (N) wire to the terminal marked 'N' on the output side.
- Double-check all connections for tightness and correctness before restoring power.
6. Iziqondiso Zokusebenza
6.1 Amandla Kuvuliwe
After successful installation and wiring, restore power to the circuit. The meter's LCD display will illuminate, showing the current readings.
6.2 Amamodi Wokubonisa
The meter features a dual-row display. The top row cycles through various temporary electrical parameters, while the bottom row consistently shows the total power consumption (kWh).
- Top Row (Rotating Display): Shows temporary kWh, Voltage (V), Current (A), Power (W), Power Factor (PF), and Frequency (Hz). This display automatically cycles through these parameters.
- Bottom Row (Static Display): Always shows the total accumulated power consumption in kWh. This value cannot be reset.
6.3 Reset Function for Temporary kWh
The temporary kWh reading can be reset to zero for monitoring consumption over specific periods.

Image 5: Diagram illustrating the reset function. The top display shows temporary power consumption (resettable), the bottom shows total power consumption (not resettable), and indicates to hold the reset button for 6 seconds.
- Locate the reset button on the front panel of the meter.
- Press and hold the reset button for approximately 6 seconds.
- The temporary kWh value on the top display will reset to zero. The total power consumption on the bottom display will remain unchanged.
7. Imininingwane
| Ipharamitha | Inani |
|---|---|
| Imodeli | I-DDS6619 |
| Kulinganiswe ngoVoltage | 120VAC |
| Ikalwe okwamanje | 5(80)A |
| Imvamisa | 60Hz |
| Ikilasi Lokunemba | 1.0 |
| Bonisa | I-LCD ene-Blue Backlight |
| Ukukhweza | Isitimela se-35mm DIN |
| Okubalulekile | Flame cishe yizona ezisetshenziswa kabanzi ABS |
| Ubukhulu bephakheji | 2.72 x 1.65 x 0.63 amayintshi |
| Isisindo | 0.48 amakhilogremu |
8. Isondlo
The DDS6619 energy meter requires minimal maintenance. Follow these guidelines to ensure its longevity:
- Keep the meter clean by wiping it with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Qinisekisa ukuthi indawo yokusebenza ihlala ngaphakathi kwezinga lokushisa elishiwo kanye nomswakama.
- Periodically check wiring connections for tightness, especially in environments subject to vibration.
- Do not expose the meter to direct sunlight for extended periods, as this may affect the LCD display.
9. Ukuxazulula izinkinga
If you encounter issues with your DDS6619 meter, refer to the following common problems and solutions:
| Inkinga | Imbangela Engenzeka | Isixazululo |
|---|---|---|
| Akukho sibonisi/imitha engavuliwe | No power supply; Incorrect wiring; Faulty meter | Check power supply to the circuit. Verify wiring connections according to the diagram. If problem persists, contact support. |
| Ukufundwa okunganembile | Incorrect wiring; Overload; External interference | Re-check wiring. Ensure load does not exceed meter's maximum current rating. Isolate from strong electromagnetic fields. |
| Temporary kWh not resetting | Reset button not held long enough | Press and hold the reset button for a full 6 seconds. |
| Total kWh reading is zero or incorrect | Incorrect wiring; Meter malfunction | Verify wiring. Note that total kWh cannot be reset. If consistently incorrect, contact support. |
10. Iwaranti kanye Nokusekela
Imikhiqizo ye-SINOTIMER ikhiqizwa ngezindinganiso zekhwalithi ephezulu. Ukuze uthole ulwazi lwewaranti noma ukwesekwa kobuchwepheshe, sicela ubheke imibhalo enikezwe ngokuthenga kwakho noma uvakashele i-SINOTIMER esemthethweni. webindawo.
Ungathola ulwazi olwengeziwe kanye nemininingwane yokuxhumana ku- SINOTIMER Store on Amazon.