The Fieldpiece SM482V is an advanced wireless 4-port SMAN refrigerant manifold designed for comprehensive HVAC and Refrigeration diagnostics and service. This digital manifold accurately measures low and high pressure, and calculates superheat and subcooling. It features protected thermocouple jacks for temperature measurements and integrates with Job Link Psychrometer probes for enhanced functionality. The device is built for durability with a heavy-duty casing and IP55 dust and water resistance.

Fieldpiece SM482V Digital Manifold Front View

Umfanekiso 1: Ngaphambili view of the Fieldpiece SM482V Wireless 4-Port SMAN Refrigerant Manifold, showing the digital display and valve controls.

Izici Eziyinhloko

Isethaphu kanye nokusebenzisa kokuqala

  1. Ukufakwa Kwebhethri: Open the battery compartment on the rear of the unit. Insert 6 AA batteries, ensuring correct polarity. Close the compartment securely.
  2. Vula: Press the power button to turn on the manifold. The display will illuminate and show initial readings.
  3. Refrigerant Selection: Use the "SELECT" button to cycle through the pre-loaded refrigerants. Choose the appropriate refrigerant for your application.
  4. I-Zero Pressure: Before connecting to a system, ensure all valves are closed and press the "ZERO PRESSURE" button to calibrate the pressure sensors.
  5. Connecting Probes: Connect thermocouple pipe clamps to the protected jacks for temperature measurements. For wireless integration, ensure Job Link Psychrometer probes are paired according to their respective manuals.
Fieldpiece SM482V with hands connecting hoses

Figure 2: The SM482V manifold being connected to an HVAC system, demonstrating hose attachment points.

Imiyalelo yokusebenza

Pressure and Temperature Measurement

Connect the manifold hoses to the high and low-pressure ports of the HVAC/R system. Open the appropriate valves on the manifold to read system pressures. The display will show real-time pressure readings, along with superheat and subcooling calculations based on connected temperature probes.

Vacuum Measurement

To measure vacuum, connect the vacuum pump to the manifold's vacuum port. Open the vacuum valve and start the pump. The integrated micron gauge will display the vacuum level. Monitor the reading until the desired vacuum is achieved.

System Tightness Test (Nitrogen Pressure Test)

The SM482V features a temperature-compensated nitrogen pressure test. Connect a nitrogen tank to the system via the manifold. Press the "N2 TEST" button to initiate the test. The manifold will record the initial pressure and monitor for pressure differential (Pdif) over time, indicating potential leaks. Press "STOP/EXIT" to end the test.

Ukungena Kwedatha

The manifold can log up to 168 hours of data. To start data logging, refer to the specific instructions in the full user manual or the Job Link System App. Logged data can be retrieved and analyzed via the Job Link App.

Fieldpiece SM482V in use on an outdoor HVAC unit

Figure 3: An HVAC technician using the Fieldpiece SM482V on an outdoor air conditioning unit.

Isondlo

Fieldpiece SM482V with included soft case

Figure 4: The Fieldpiece SM482V manifold alongside its protective soft case.

Ukuxazulula inkinga

InkingaImbangela EngenzekaIsixazululo
Ukufundwa Kwengcindezi OkungalungileUncalibrated sensors, leaky hoses/gaskets, incorrect refrigerant selected.Perform "ZERO PRESSURE" calibration. Inspect and replace worn hoses or gaskets. Verify correct refrigerant is selected.
Vacuum Reading FluctuationsMoisture in system, internal manifold leak, contaminated hoses.Ensure system is thoroughly evacuated. Check manifold for internal leaks (refer to service manual). Purge hoses with nitrogen before vacuuming.
Isibonisi AsivuliAmabhethri afile, ukufakwa kwebhethri okungalungile.Shintsha amabhethri ngamasha. Hlola i-polarity yebhethri.
Izinkinga Zokuxhuma OkungenantamboOut of range, interference, un-paired probes.Ensure manifold and probes are within range (up to 1000ft line of sight). Reduce interference sources. Re-pair probes according to their instructions.

Imininingwane

IsiciImininingwane
ImodeliI-SM482V
Isisindo sento5.79 pounds (2.63 kg)
Ubukhulu bomkhiqizo (L x W x H)5 x 10.25 x 11.25 amayintshi (12.7 x 26.0 x 28.6 cm)
OkubalulekileIpulasitiki ye-ABS
Umthombo wamandla6 AA Amabhethri
Impilo Yebhethri405 hours (with backlight and wireless OFF)
Bonisa5" (12.7 cm) LCD w/ backlight
Uhlobo olungenantambo1000' (305 m) line of sight
Maximum Manifold Pressure870 Psig (6000 kPa)
Umshini Wembobo3/8" for fast evacuations
Refrigerant Recovery/Charging Port1/4"
Suction Line and Liquid Line Ports1/4"
Isilinganiso sokuvikelwa kwe-IngressIP55 (Dust/Water Resistance)
Indawo yokusebenza14° to 122° F (-10° to 50° C) at <75% RH
Indawo Yesitoreji-4° to 140° F (-20° to 60° C) at <80% RH (w/o batteries)
Imbobo YedathaUSB-C for extracting data logs and updating firmware
Fieldpiece SM482V Specifications Comparison Table

Figure 5: Detailed specifications table comparing SM382V and SM482V models.

Ulwazi Lwewaranti

The Fieldpiece SM482V Wireless 4-Port SMAN Refrigerant Manifold comes with a Iwaranti ekhawulelwe yeminyaka engu-1 from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For detailed warranty terms, conditions, and limitations, please refer to the official warranty document included with your product or visit the Fieldpiece official webindawo.

Qaphela: The warranty does not cover damage caused by misuse, accident, unauthorized modification, neglect, or improper operation.

Ukusekela kanye Nolwazi Lokuxhumana

For technical assistance, product inquiries, or warranty claims, please contact Fieldpiece customer support through the following channels:

When contacting support, please have your product model number (SM482V) and purchase date available.

Amadokhumenti Ahlobene - I-SM482V

Ngaphambiliview Fieldpiece SMAN® Refrigerant Manifold Operator's Manual
Operator's manual for the Fieldpiece SMAN® Refrigerant Manifold with Built-in Vacuum Gauge (Models SM382V and SM482V), detailing features, operation, specifications, and maintenance for HVACR professionals.
Ngaphambiliview Fieldpiece SMAN Refrigerant Manifold Operator's Manual
Comprehensive operator's manual for Fieldpiece SMAN Refrigerant Manifolds (Models SM382V and SM482V) with built-in vacuum gauges. Covers features, operation, maintenance, specifications, safety, and troubleshooting for HVACR professionals.
Ngaphambiliview Fieldpiece SMAN® Coletor de Refrigerante com Vacuómetro Incorporado - Manual do Operador
Manual do operador detalhado para os coletores de refrigerante Fieldpiece SMAN® com vacuómetro incorporado (modelos SM382VINT e SM482VINT). Abrange operação, segurança, manutenção e especificações para profissionais de HVACR.
Ngaphambiliview Manuel d'utilisation des manifolds pour fluide frigorigène Fieldpiece SMAN® avec jauge à vide intégrée
Manuel d'utilisation complet pour les manifolds pour fluide frigorigène Fieldpiece SMAN® modèles SM382VINT (3 ports) et SM482VINT (4 ports). Ce document couvre les caractéristiques, le fonctionnement, les procédures de sécurité, l'entretien, les spécifications techniques et le dépann#age.
Ngaphambiliview Fieldpiece SM480V SMAN Refrigerant Manifold + Micron Gauge Operator's Manual
Comprehensive operator's manual for the Fieldpiece SM480V SMAN Refrigerant Manifold and Micron Gauge, detailing features, operation, maintenance, specifications, and compliance for HVACR professionals. Covers setup, measurements, calculations, menu functions, and troubleshooting.
Ngaphambiliview Fieldpiece SM380V SMAN Refrigerant Manifold + Micron Gauge Operator's Manual
Operator's manual for the Fieldpiece SM380V SMAN Refrigerant Manifold + Micron Gauge (3 Port). This guide provides detailed information on features, operation, specifications, maintenance, and troubleshooting for HVACR professionals.