IBO AMG 25-80/180

IBO AMG 25-80/180 Electronic Circulation Pump User Manual

Model: AMG 25-80/180

1. Isingeniso

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your IBO AMG 25-80/180 electronic circulation pump. This energy-efficient pump is designed for use in heating systems, ensuring optimal circulation of the pumped liquid. Please read this manual thoroughly before installation and operation to ensure proper function and longevity of the product.

IBO AMG 25-80/180 Electronic Circulation Pump

Umfanekiso 1: The IBO AMG 25-80/180 electronic circulation pump, showcasing its compact design and integrated power cord.

2. Imiyalelo Yezokuphepha Ebalulekile

Failure to follow these safety instructions may result in electric shock, fire, or serious injury. Keep this manual for future reference.

Warning label on IBO circulation pump

Umfanekiso 2: Side view of the pump highlighting the warning label, which emphasizes reading the manual, avoiding dry operation, and ensuring proper grounding.

3. Imininingwane Yezobuchwepheshe

IsiciUkucaciswa
ImodeliAMG 25-80/180
Amamodi Okusebenza8
Ikilasi LokuvikelaIP44
Liquid lokushisa Ibanga2°C kuya +110°C
Amandla Ezimoto65 W
Maximum Lifting Height8 amamitha
Isilinganiso sokugeleza esiphezulu65 Amalitha Ngomzuzu
Ubukhulu bomkhiqizo (L x W x H)20 x 10 x 15 cm
Isisindo2.8 kg
OkubalulekilePlastic (housing), Metal (pump body)
Uhlobo Lomthombo WamandlaElectric component with cord
Close-up of IBO pump label with specifications

Umfanekiso 3: Ukuvala view of the pump's product label, displaying model number, power, and other technical data.

4. Ukufakwa

Proper installation is crucial for the pump's performance and safety. If you are unsure about any step, consult a qualified professional.

4.1 Ukuqaqa kanye Nokuhlola

IBO circulation pump with included gaskets and fittings

Umfanekiso 4: The IBO circulation pump displayed with its accompanying gaskets and fittings, essential for installation.

Close-up of gaskets and fittings for IBO pump

Umfanekiso 5: A enemininingwane view of the gaskets and fittings provided with the pump, used to ensure a watertight seal during installation.

4.2 Ukufaka Iphampu

Ngaphambili view of IBO circulation pump

Umfanekiso 6: Ngaphambili view of the IBO circulation pump, showing the inlet and outlet connections.

4.3 Ukuxhunywa kukagesi

5. Ukusebenza

The IBO AMG 25-80/180 pump features 8 operating modes, including an intelligent Auto-Mode, to optimize energy consumption and system performance.

5.1 Ukuqala kokuqala

  1. Before starting, ensure the heating system is filled with water and properly vented to remove any air. Running the pump with air can cause damage.
  2. Once the system is filled and vented, connect the pump to the power supply.
  3. The pump will typically perform a self-test upon initial power-up.

5.2 Ukukhetha Izindlela Zokusebenza

The pump's control panel allows you to select from 8 different operating modes. These modes are designed to adapt to various system requirements and optimize energy efficiency.

Refer to the markings on the pump's control panel for specific mode indicators and selection buttons. Press the mode button to cycle through the available settings until the desired mode is selected.

I-engeli view of IBO circulation pump control panel

Umfanekiso 7: I-engeli view of the IBO circulation pump, showing the control panel with indicators for different operating modes (PP, CP, AUTO) and speed settings (1, 2, 3).

6. Isondlo

Regular maintenance ensures the long-term reliability and efficiency of your circulation pump. Always disconnect the pump from the power supply before performing any maintenance.

6.1 Amasheke Ajwayelekile

6.2 Ukuhlanza

6.3 Ukushintsha kwesimo sasebusika (uma kusebenza)

If the pump is installed in an area prone to freezing and the heating system will be shut down for an extended period, ensure the system is drained to prevent damage from freezing water.

7. Ukuxazulula izinkinga

Ngaphambi kokuxhumana nosekelo lobuchwepheshe, review izinkinga ezilandelayo ezivamile kanye nezixazululo zazo ezingaba khona.

InkingaImbangela EngenzekaIsixazululo
Ipompo ayiqaliNo power supply; Blown fuse/tripped breaker; Motor blockageCheck power connection; Reset breaker/replace fuse; Disconnect power and check for impeller blockage (consult professional if unsure).
No or insufficient flowAir in the system; Closed valves; Blockage in pipes/pump; Incorrect operating modeVent the system; Open all relevant valves; Check for blockages; Select appropriate operating mode.
Iphampu linomsindoAir in the system; Cavitation; Foreign objects in pump; Worn bearingsVent the system thoroughly; Ensure adequate system pressure; Disconnect power and inspect impeller; Contact service if noise persists.
Ukuvuza kwephampuLoose connections; Damaged gaskets/sealsTighten pipe connections; Replace damaged gaskets (ensure power is off and system is drained).

8. Ulwazi Lwewaranti

Warranty terms and conditions for the IBO AMG 25-80/180 electronic circulation pump are typically provided at the point of purchase or included with the product packaging. Please retain your proof of purchase for warranty claims. For detailed information regarding the warranty period and coverage, refer to the documentation supplied by your retailer or contact IBO customer support directly.

9. Ukwesekwa Kwamakhasimende

If you encounter issues that cannot be resolved using the troubleshooting guide, or require further assistance, please contact IBO customer support or your authorized dealer. When contacting support, please have your pump's model number (AMG 25-80/180) and purchase details readily available.

For the most up-to-date contact information, please visit the official IBO webindawo.

Amadokhumenti Ahlobene - AMG 25-80/180

Ngaphambiliview IBO AMG & AMG SOLAR Circulation Pumps - User Manual
Comprehensive user and installation manual for IBO AMG and AMG SOLAR energy-efficient circulation pumps. Covers safety, installation, operation, technical specifications, troubleshooting, and EU declaration of conformity.
Ngaphambiliview Návod k obsluze čerpadel IBO AMG a AMG SOLAR
Podrobný návod k obsluze, instalaci a údržbě energeticky účinných oběhových čerpadel IBO řady AMG a AMG SOLAR. Zahrnuje technické specifikace, bezpečnostní pokyny a řešení problémů pro topné a solární systémy.
Ngaphambiliview Návod k použití: IBO AUTO IBO Povrchová čerpadla a Hydrofory
Kompletní návod k použití pro povrchová čerpadla a hydrofory IBO AUTO IBO. Obsahuje informace o instalaci, provozu, údržbě, řešení problémů a technické specifikace.
Ngaphambiliview IBO OHI / OHI MAX Circulation Pump Instruction Manual
Comprehensive instruction manual for IBO OHI and OHI MAX series circulation pumps, covering safety, installation, operation, technical specifications, and troubleshooting. Includes EC declaration of conformity and warranty information.
Ngaphambiliview IBF-02 Magnetic Separator - Operating Manual and Installation Guide
Comprehensive operating manual and installation guide for the IBO IBF-02 Magnetic Separator, detailing its features, technical specifications, installation procedures, maintenance, and safety precautions for central heating systems.
Ngaphambiliview IBO IBF-01 Magnetic Filter with Ball Valve - User Manual and Technical Specifications
Comprehensive user manual and technical specifications for the IBO IBF-01 magnetic filter with ball valve. Learn about installation, operation, maintenance, safety precautions, and warranty.