Isingeniso
This manual provides comprehensive instructions for the setup, operation, and maintenance of the Unitech MS852 Rugged 2D Imager Barcode Scanner. The MS852 is designed for efficient and reliable barcode scanning in various environments, including retail, hospitality, and general purpose applications. Its intuitive design and robust construction ensure ease of use and long-term durability.
Izici Eziyinhloko
- Idizayini Engasindi: Weighs only 147g without the cable, ensuring comfortable extended use.
- Ukusekelwa Kwebhakhodi Ehlukahlukene: Capable of scanning most 1D and 2D barcodes, including those on mobile screens, and even damaged or poorly printed codes.
- Durable Trigger: Features a long lifecycle trigger designed for up to 10,000,000 activations, ensuring continuous productivity.
- Ukushintsha Imodi Ezenzakalelayo: Automatically switches between trigger mode and presentation mode when used with its stand, enhancing user experience.
- Ultra-Rugged Construction: IP42 rated for protection against dust and moisture, and tested to withstand 2.1-meter drops to concrete.
Setha
1. Ukuhlolwa Kokuqala
Upon unpacking, inspect the scanner and all accessories for any signs of damage. Ensure all components listed in the packaging are present.

Umfanekiso 1: Ngaphambili-kwesokudla view of the Unitech MS852 Barcode Scanner.
2. Ukuxhuma Iskena
The MS852 scanner is a plug-and-play device. Connect the USB cable from the scanner to an available USB port on your computer or point-of-sale system. No additional driver installation is typically required.

Umfanekiso 2: Uhlangothi view of the Unitech MS852 Barcode Scanner, showing its ergonomic design.
3. Using the Scanner Stand (Optional)
If your package includes a scanner stand, assemble it according to the instructions provided with the stand. Placing the scanner in the stand will automatically switch it to presentation mode, allowing for hands-free scanning.

Figure 3: The Unitech MS852 Barcode Scanner mounted on its flexible stand, ready for presentation mode.

Figure 4: Illustration of the Unitech MS852 Barcode Scanner's versatile mounting options, including wall mount and desktop stand configurations.
Imiyalelo yokusebenza
1. Ukuskena Okuyisisekelo
To scan a barcode, point the scanner's window at the barcode and press the trigger button. A successful scan will be indicated by an audible beep and a visual LED indicator.

Umfanekiso 5: Ngaphambili view of the Unitech MS852 Barcode Scanner, highlighting the scan window.
2. Scanning Modes
- Imodi yokuqalisa: The scanner activates the scan engine only when the trigger button is pressed. This is ideal for targeted scanning.
- Imodi Yesethulo: When placed in its stand, the scanner automatically detects objects in its field of view and scans them without requiring a trigger press. This mode is suitable for high-volume, hands-free scanning.
3. Feedback Indicators
- I-Beeper: A loud beeper provides audible confirmation of successful scans.
- Inkomba ye-LED: A bright LED indicator provides visual confirmation of successful scans, especially useful in noisy environments.
Isondlo
1. Ukuhlanza
Ukuze ugcine ukusebenza kahle, hlanza njalo ifasitela nengaphandle lesithwebuli. Sebenzisa indwangu ethambile, engenabo uboya kancaneampkufakwe amanzi noma isisombululo sokuhlanza esithambile, esingagugi. Ungasebenzisi amakhemikhali aqinile noma izinto ezigugisayo.
2. Isitoreji
Store the scanner in a cool, dry place away from direct sunlight and extreme temperatures. When not in use for extended periods, disconnect it from the power source.
Ukuxazulula inkinga
| Inkinga | Imbangela Engenzeka | Isixazululo |
|---|---|---|
| Scanner not responding | Loose USB connection; Incorrect USB port; Computer issue. | Ensure USB cable is securely connected. Try a different USB port. Restart the computer. |
| Ayikwazi ukuskena amabhakhodi | Barcode damaged/poorly printed; Incorrect symbology enabled; Scanner window dirty; Insufficient lighting. | Try scanning a known good barcode. Refer to the programming guide for symbology settings. Clean the scanner window. Ensure adequate lighting. |
| No beep/LED feedback | Feedback settings disabled; Hardware malfunction. | Check scanner programming guide for feedback settings. If issue persists, contact support. |
Imininingwane
| Isici | Imininingwane |
|---|---|
| Inombolo Yemodeli | MS852-AUCB00-SG |
| Ubukhulu bomkhiqizo | 3.4 x 2.8 x 6.9 amayintshi |
| Isisindo sento | 10.6 ama-ounces (cishe 300g) |
| Ubuchwepheshe bokuxhumana | Ikhebula le-USB (Elinezintambo) |
| Umthombo wamandla | Intambo kagesi, Ikhebula le-USB |
| Amadivayisi Ahambisanayo | Laptop, Smartphone, Tablet, iPhone (via USB OTG if supported) |
| Yehlisa Imininingwane | 2.1 meters to concrete |
| Isilinganiso se-IP | IP42 (Ukuvikelwa ezintweni eziqinile >1mm kanye namanzi agelezayo) |
| Trigger Lifecycle | Kufika izikhathi ezi-10,000,000 |
| Umkhiqizi | I-Unitech |
Ulwazi Lwewaranti
Unitech products are manufactured to the highest quality standards. For specific warranty terms and conditions applicable to your MS852 scanner, please refer to the warranty card included with your product or visit the official Unitech webindawo. Gcina ubufakazi bakho bokuthenga ngezimangalo zewaranti.
Ukusekela
For technical assistance, product inquiries, or service requests, please contact Unitech customer support. Contact information can typically be found on the Unitech official webisayithi noma kumadokhumenti anikezwe nomkhiqizo wakho.
Izinsiza eziku-inthanethi: Visit the Unitech website for FAQs, driver downloads, and additional product information.