SHARP AH-XP12WMT

Incwadi Yomsebenzisi ye-SHARP AC AH-XP12WMT INV

Model: AH-XP12WMT

1. Isingeniso

This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your SHARP AH-XP12WMT INV Inverter Split Air Conditioner. Please read this manual thoroughly before using the appliance and retain it for future reference.

The SHARP AH-XP12WMT INV is a 1 Ton Inverter Split AC designed to provide a comfortable indoor environment. It features a copper condenser and a dust filter for enhanced performance and air quality.

Ngaphambili view of the SHARP AH-XP12WMT INV indoor air conditioner unit, white in color.

Image: SHARP AH-XP12WMT INV Indoor Unit. This image shows the overall appearance of the air conditioner's indoor unit.

2. Ukusetha nokufakwa

Proper installation is crucial for the optimal performance and longevity of your air conditioner. It is highly recommended that installation be performed by a qualified and certified technician.

2.1 Ukuqaqa

Carefully unpack all components. Ensure all parts are present and undamaged. The package includes the indoor unit, outdoor unit, remote control, and a hose.

2.2 Imicabango yokubeka

The indoor unit (IDU) dimensions are 87.70 cm (Width) x 22.20 cm (Depth) x 29.20 cm (Height). Ensure adequate space for air circulation and maintenance.

Diagram showing the dimensions of the SHARP AH-XP12WMT INV indoor unit: 87.7 cm width, 22.2 cm depth, and 29.2 cm height.

Image: Indoor Unit Dimensions. This diagram illustrates the physical measurements of the indoor unit, crucial for planning installation space.

2.3 Ukuxhunywa kukagesi

The unit operates on 230 Volts. Ensure the electrical supply meets the requirements and a dedicated circuit is used. All electrical work must comply with local codes and regulations.

3. Iziqondiso Zokusebenza

Your SHARP AC AH-XP12WMT INV is controlled via a remote control. Familiarize yourself with the remote's functions for optimal use.

3.1 Ukusebenza Okuyisisekelo

  1. Vula/Vala: Cindezela inkinobho yamandla kusilawuli kude ukuze uvule noma uvale iyunithi.
  2. Ukulungiswa Kwezinga Lokushisa: Use the temperature up/down buttons to set your desired room temperature.
  3. Ukukhetha Imodi: Select operating modes such as Cool, Fan, Dry, or Auto using the mode button.
  4. Isivinini saphephela: Adjust the fan speed to your preference (Low, Medium, High, Auto).

3.2 Izici Ezikhethekile

4. Isondlo

Ukunakekelwa okuvamile kuqinisekisa ukusebenza kahle futhi kwelula isikhathi sokuphila se-air conditioner yakho.

4.1 Ukuhlanza Isihlungi

The dust filter should be cleaned regularly, typically every two weeks or more often depending on usage and air quality. To clean:

  1. Turn off the air conditioner and disconnect power.
  2. Vula iphaneli yangaphambili yeyunithi yasendlini.
  3. Susa izihlungi zomoya.
  4. Hlanza izihlungi nge-vacuum cleaner noma uzigeze ngamanzi afudumele kanye nesihlanzi esithambile.
  5. Allow filters to dry completely before reinstalling.
  6. Vala iphaneli yangaphambili.

4.2 Ukuhlanza Okujwayelekile

Sula ingaphandle lamayunithi angaphakathi nangaphandle ngesithambile, damp cloth. Do not use harsh chemicals or abrasive cleaners. Ensure the outdoor unit's coils are free from debris.

5. Ukuxazulula izinkinga

Ngaphambi kokuxhumana nesevisi, review these common issues and solutions.

For persistent problems or issues not listed here, contact a qualified service technician.

6. Imininingwane

Key technical specifications for the SHARP AH-XP12WMT INV Air Conditioner:

Infographic summarizing key features of the SHARP AH-XP12WMT INV AC: Inverter Split AC, Copper Condenser, 1 Ton Capacity, 3 Star Rating, 3520 Watts Power, 130 Sq. Ft. Approx. Coverage Area.

Image: Product Features Summary. This infographic highlights the main characteristics and benefits of the air conditioner.

IsiciUkucaciswa
IbhrendiSHARP
ImodeliAH-XP12WMT INV
Inombolo Yengxenye91001829
Amandla1 amathani
Ukusetshenziswa Kwezamandla Ngonyaka719 Kilowatts
Izinga Lomsindo52 Decibel
Uhlobo LokufakaUhlelo Lokuhlukanisa
Izici ezikhethekileDust Filter, Follow Me Sensor Mode
UmbalaEmhlophe
Control ConsoleIsilawuli kude
Voltage230 volts
Wattage3520 KW
IsitifiketiInkanyezi yamandla
OkubalulekileIthusi
Izingxenye EzihlanganisiweHose
Product Dimensions (IDU)22.2D x 87.7W x 29.2H Amasentimitha
Isilinganiso senkanyezi ye-BEE3 Inkanyezi
Approximate Coverage Area130 Sq. Ft (12.07 Sq. M)

7. Iwaranti kanye Nokusekela

For warranty information and technical support, please refer to the warranty card included with your product or contact SHARP customer service directly. Keep your purchase receipt as proof of purchase for warranty claims.

Umkhiqizi: SHARP

Date First Available: 23 April 2021

Amadokhumenti Ahlobene - AH-XP12WMT

Ngaphambiliview Sharp Split-Type Air Conditioner Installation Manual
This manual provides detailed instructions for the installation of Sharp's inverter one-two, one-three, and one-four split-type air conditioners, focusing on the outdoor unit. It covers safety precautions, installation steps, wiring, refrigerant piping, air evacuation, and testing.
Ngaphambiliview Imanuwali Yokusebenza Yegumbi Lomoya Wokupholisa Ocijile
Le manuwali yokusebenza inikeza isiqondiso esibalulekile sokusetshenziswa nokugcinwa okufanele kwama-air conditioner egumbi lokuhlukaniswa kwe-Sharp, ukusebenza okumbozayo, ukuphepha, izingxenye, isilawuli kude, kanye nokuxazulula izinkinga.
Ngaphambiliview Imanuwali Yokusebenza Yegumbi Lomoya Wokupholisa Ocijile
This operation manual provides detailed instructions for using Sharp split type room air conditioners, covering basic operations, advanced features, safety precautions, and maintenance.
Ngaphambiliview Sharp Air Conditioner Owner's Manual - AH-XC9XV, AH-XC12XV, AU-X3M21XV, AU-X4M28XV
Owner's manual for Sharp Inverter One-Two/One-Three/One-Four Split-Type Air Conditioners, covering safety precautions, unit parts, functions, operation, maintenance, and troubleshooting for models AH-XC9XV, AH-XC12XV, AU-X3M21XV, and AU-X4M28XV.
Ngaphambiliview Imanuwali Yokusebenza Yegumbi Lomoya Wokupholisa Ocijile
Incwadi yokusebenza ephelele yama-Sharp Split Type Room Air Conditioners, ehlanganisa ukusebenza okuyisisekelo, imiyalelo yokuphepha, ukulungiswa, ukuxazulula izinkinga, kanye nezindlela ezikhethekile njenge-Super Jet, i-Baby Mode, kanye ne-Eco Mode. Ifaka uchungechunge lwamamodeli i-AH-X kanye ne-AU-X.
Ngaphambiliview Imanuwali Yokusebenza Yegumbi Lomoya Wokupholisa Ocijile
Comprehensive operation manual for Sharp Split Type Room Air Conditioners, covering safety instructions, part names, remote control usage, basic operation, special modes (Super Jet, Baby, Eco, Timer, Best Sleep), maintenance, troubleshooting, and error code retrieval. Includes guidance in English, Thai, and Vietnamese.