1. Umkhiqizo Uphelileview
The Elitech LogEt 8 THE is a reusable digital data logger designed for monitoring temperature and humidity. It is suitable for various applications, including cold chain management for pharmaceuticals, vaccines, food, and other sensitive products. This device features high precision sensors, multiple alarm thresholds, and direct USB connectivity for data download and report generation.

Image: Elitech LogEt 8 THE Digital Temperature and Humidity Data Logger with its external probe. The device displays "32.9" and has "START" and "STOP" buttons.
2. Izici Eziyinhloko
- High-precision Temperature & Humidity Sensor: Wide temperature range from -40°F to 185°F with ±0.5°F accuracy. Humidity measuring range: 10%RH to 90%RH, with ±3%RH accuracy.
- Ama-alamu amaningi: Configurable with up to 5 alarm thresholds (3 high, 2 low).
- Plug and Read Functionality: Direct USB connection for data download without requiring a separate cable or reader.
- Automatic PDF Report Generation: Encrypted PDF reports are automatically generated with password protection. Free Elitechlog software provides personalized settings and management.
- Long Working Life: Utilizes a replaceable lithium battery for extended operation.
3. Izingxenye Zedivayisi

Image: Diagram illustrating the components of the Elitech LogEt 8 THE data logger. Key components include: 1. USB Port, 2. LCD Screen, 3. Buttons (START/STOP), 4. External Temperature and Humidity Sensor, and 5. Battery Cover.
- Imbobo ye-USB: Used for connecting to a computer for data download and configuration.
- Isikrini se-LCD: Displays current temperature, humidity, and device status.
- Izinkinobho: "START" button to initiate logging, "STOP" button to cease logging.
- Inzwa Yangaphandle Yezinga lokushisa Nomswakama: Provides accurate environmental readings.
- Ikhava yebhethri: Protects the replaceable lithium battery compartment.
4. Setha
4.1 Ukuhlolwa Kokuqala
Upon receiving your LogEt 8 THE data logger, inspect the packaging and device for any signs of damage. Ensure all included components (data logger, calibration certificate, user manual) are present.
4.2 Ukufakwa Kwesofthiwe
Before first use, download and install the Elitechlog software from the official Elitech website. This software is required for device configuration, data download, and report generation.
- Vakashela isikhulu se-Elitech webindawo.
- Navigate to the support or download section.
- Download the Elitechlog software compatible with your operating system (Windows/macOS).
- Landela imiyalelo esesikrinini ukuze uqedele ukufaka.

Image: The Elitech LogEt 8 THE data logger plugged into a laptop's USB port, illustrating the data export process via ElitechLogWin software to PDF, Excel, or TXT formats.
4.3 Ukucushwa Kwedivayisi
Connect the data logger to your computer via the USB port. The Elitechlog software will detect the device. Use the software to configure parameters such as:
- Isikhawu sokungena
- Qala ukubambezeleka
- Alarm thresholds (high/low temperature and humidity)
- Iyunithi yezinga lokushisa (°C/°F)
- Indawo yesikhathi
Ensure the external temperature and humidity sensor is securely connected to the device before deployment.
5. Ukusebenza
5.1 Starting Data Logging
Cindezela bese ubamba i QALA button for approximately 3 seconds until the "REC" indicator appears on the LCD screen. This indicates that the device has begun recording data according to the configured settings.
5.2 Stopping Data Logging
Ukumisa ukuloga, cindezela bese ubamba i IMA button for approximately 3 seconds. The "REC" indicator will disappear from the LCD screen, confirming that logging has ceased.
5.3 Reading Data and Generating Reports
After logging is complete, connect the data logger to a computer via the USB port. The Elitechlog software will automatically recognize the device and prompt you to download the recorded data. The software will then generate an encrypted PDF report, which can also be exported to Excel or TXT formats for further analysis.

Image: A visual representation of the Elitech LogEt 8 THE data logger connected to a computer, showing the generation of a PDF report. The report includes a graph of temperature and humidity data over time.
5.4 Ukuvikelwa Kwephasiwedi
The generated PDF reports can be password-protected for enhanced data security. This feature is configured within the Elitechlog software.
6. Isondlo
6.1 Ukushintshwa Kwebhethri
The LogEt 8 THE uses a replaceable lithium battery. When the battery indicator on the LCD screen shows low power, replace the battery to ensure continuous and accurate operation. To replace the battery:
- Locate the battery cover (Component 5 in the diagram).
- Vula kahle ikhava yebhethri.
- Remove the old battery and insert a new compatible lithium battery, observing polarity.
- Vala ikhava yebhethri ngokuphephile.
6.2 Ukuhlanza
Wipe the device clean with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is dry before use.
6.3 Isitoreji
When not in use for extended periods, store the data logger in a cool, dry place away from direct sunlight and extreme temperatures. Remove the battery if storing for very long durations to prevent leakage.
7. Ukuxazulula izinkinga
| Inkinga | Imbangela Engenzeka | Isixazululo |
|---|---|---|
| Idivayisi ayivuli. | Ibhethri liphansi noma eliphelile. | Shintsha ibhethri. |
| Data not logging. | Logging not initiated or stopped prematurely. | Qinisekisa ukuthi QALA button was pressed and held until "REC" appears. Check battery level. |
| Cannot connect to computer/software. | USB connection issue; software not installed or outdated. | Ensure the device is fully inserted into the USB port. Verify Elitechlog software installation and update to the latest version. Try a different USB port. |
| Ukufundwa okungalungile. | Sensor obstruction or damage; device placed in extreme conditions. | Ensure the external sensor is clean and unobstructed. Relocate the device to a suitable environment within its operating range. |
| PDF report not generated. | Software error; insufficient disk space. | Restart the Elitechlog software and try again. Ensure sufficient storage space on your computer. |
8. Imininingwane
| Isici | Imininingwane |
|---|---|
| Inombolo Yemodeli | LogEt 8 THE |
| Izinga Lokushisa | -40°F ukuya ku-185°F (-40°C kuya ku-85°C) |
| Ukunemba kwezinga lokushisa | ± 0.5 ° F (± 0.3 ° C) |
| Ububanzi Bomswakama | 10% RH kuya ku-90% RH |
| Ukunemba Komswakama | ± 3% RH |
| Record Amandla | 16000 amaphuzu |
| Ukuxhumana | I-USB |
| Ifomethi yombiko | PDF (automatic, encrypted), Excel, TXT |
| Umthombo wamandla | 1 Lithium Metal battery (included, replaceable) |
| Ubukhulu bomkhiqizo | 4 x 1.8 x 0.8 amayintshi |
| Isisindo | 3.17 amakhilogremu |
| Izingxenye Ezihlanganisiwe | Data Logger, Calibration Certificate, User Manual |

Image: The Elitech LogEt 8 THE data logger displaying its temperature range from -40°C/-40°F to 85°C/185°F and indicating a 16000 points record capacity.
9. Iwaranti kanye Nokusekela
Elitech provides US Technician Support via Email and Phone for any inquiries or issues you may encounter with your LogEt 8 THE data logger. Please refer to the official Elitech website or the included documentation for specific warranty terms and contact information.
For technical assistance, please visit the Elitech official webindawo noma xhumana nethimba labo lokusekela ngqo.





