1. Isingeniso
The Veroval® duo control arm blood pressure monitor is designed for individuals who monitor their blood pressure daily, including those with cardiovascular conditions such as arrhythmias. This device ensures precise blood pressure measurement through its innovative DUO SENSOR technology.
The DUO SENSOR technology uniquely combines two professional measurement methods: the oscillometric method, which detects pulse waves, and the Korotkoff method, which uses a microphone to record heart sounds. This dual approach provides reliable measurements, even for patients experiencing heart rhythm disorders, a capability often relied upon by medical professionals.

Image 1.1: The Veroval duo control device, showing its large digital display with blood pressure and pulse readings.
2. Ulwazi Lokuphepha
Okubalulekile: Please read these instructions for use carefully and completely before operating the device. Failure to do so may result in inaccurate readings or device malfunction.
- This device is a medical product. Consult your doctor or pharmacist for advice, especially if you have pre-existing medical conditions or are on medication.
- Do not use the device on infants, children, or individuals unable to understand the instructions.
- Avoid taking measurements in environments with strong electromagnetic fields (e.g., near mobile phones, microwave ovens).
- Ungaqaqi noma uzame ukulungisa idivayisi ngokwakho. Xhumana nabasebenzi besevisi abagunyaziwe nganoma yikuphi ukulungiswa.
- Store the device and its components out of reach of children and pets.
- Use only the original cuff provided with the device.
- Ensure the cuff is correctly positioned on the arm as indicated in the operating instructions.
3. Okuqukethwe Kwephakheji
Your Veroval duo control blood pressure monitor package includes the following items:
- Veroval duo control Blood Pressure Monitor unit
- Secure-Fit Arm Cuff (Size M, 22-32 cm circumference)
- Storage Bag/Case
- 4 x AAA 1.5V Amabhethri
- USB Cable (for data transfer)
- Incwadi Yokufundisa (le dokhumenti)

Image 3.1: The Veroval duo control blood pressure monitor shown within its product packaging, highlighting key features.
4. Izici zomkhiqizo
The Veroval duo control blood pressure monitor is equipped with advanced features for accurate and convenient blood pressure monitoring:
- DUO SENSOR Technology: Combines oscillometric and Korotkoff methods for highly reliable measurements, even in the presence of cardiac arrhythmias.
- Comfort Air Technology: Ensures a comfortable and gentle measurement process.
- Secure-Fit Cuff: Designed for easy and correct positioning on the arm, with an integrated cuff position control indicator.
- Rest Indicator: Guides the user to ensure they are in a relaxed state before measurement, contributing to accurate readings.
- Isibonisi esikhulu se-LCD esikhanyayo: Provides clear visibility of readings and indicators.
- Umsebenzi Wenkumbulo: Stores 200 measurements (100 for each of two users), including date and time.
- Ukuxhumana kwe-Bluetooth: Seamlessly transfer data to the Veroval medi.connect app for long-term analysis and management.
- Ukuhlaziywa Kwedatha: The Veroval medi.connect software/app offers color-coded classification of values, displays averages of all stored values, and morning/evening blood pressure averages for the last 7 days.
- Kuqinisekiswe Ngokwezokwelapha: Measurement quality proven by quality labels from the European Society of Hypertension (ESH), German Hypertension League (DHL), and British Hypertension Society (BHS).
5. Setha
5.1. Ukufakwa kwebhethri
- Vula ikhava yengxenye yebhethri ngemuva kwedivayisi.
- Insert the 4 AAA 1.5V batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Vala ikhava yengxenye yebhethri ngokuphephile.
5.2. Ukufaka i-Arm Cuff
- Locate the air tube connector on the cuff.
- Insert the air tube connector firmly into the air jack on the side of the main unit.

Image 5.1: The Veroval duo control unit alongside its Secure-Fit arm cuff, demonstrating the separate components.
5.3. Initial Settings (Date and Time)
Upon first use or after battery replacement, the device may prompt you to set the date and time. Refer to the on-screen prompts and use the device buttons to adjust these settings for accurate record-keeping.
6. Iziqondiso Zokusebenza
6.1. Preparing for Measurement
- Phumula okungenani imizuzu emi-5 ngaphambi kokuthatha isilinganiso.
- Hlala ngokunethezeka nomhlane wakho usekelwe futhi izinyawo ziphansi phansi.
- Place your arm on a table so that the cuff is at heart level.
- Gwema ukukhuluma noma ukunyakaza ngesikhathi sokulinganisa.
6.2. Ukufaka iCuff
- Slide the cuff onto your bare upper arm, ensuring the air tube points towards your forearm.
- The bottom edge of the cuff should be approximately 2-3 cm above your elbow joint.
- Wrap the cuff snugly around your arm. The Secure-Fit design and on-screen cuff position control indicator will help ensure correct placement.
- The rest indicator on the display will guide you to ensure you are sufficiently relaxed before the measurement begins.
6.3. Ukuthatha Isilinganiso
- Khetha umsebenzisi wakho onguchwepheshefile (User 1 or User 2) if applicable.
- Press the START/STOP button to begin the measurement. The cuff will inflate automatically.
- Remain still and quiet until the measurement is complete and the cuff deflates.
- Your systolic (SYS), diastolic (DIA) blood pressure, and pulse (PUL) readings will be displayed on the screen.
- The device will also indicate if an irregular heartbeat (arrhythmia) was detected during the measurement.
- The measurement will automatically be stored in the selected user's memory.
6.4. Recalling Measurements
Press the "Memory" button (often indicated by an 'M' or a book icon) to scroll through previously stored measurements for the active user. You can view individual readings, as well as morning and evening averages.
7. Data Management with Veroval medi.connect
The Veroval duo control blood pressure monitor offers seamless data management through the Veroval medi.connect application, available for Android and iOS devices, including tablets.
7.1. Ukulanda uhlelo lokusebenza
Download the "Veroval medi.connect" app from your device's app store (Google Play Store for Android or Apple App Store for iOS).
7.2. Ixhuma nge-Bluetooth
- Qinisekisa ukuthi i-Bluetooth ivuliwe ku-smartphone noma kuthebulethi yakho.
- Open the Veroval medi.connect app and follow the on-screen instructions to pair your blood pressure monitor.
- Once paired, your stored measurements will automatically synchronize with the app.
7.3. Analyzing Your Data
The app provides comprehensive tools for analyzing your blood pressure trends:
- Color-Coded Classification: Readings are categorized using a color system for easy interpretation of blood pressure levels.
- Amanani Amaphakathi: View averages of all your stored measurements.
- Morning and Evening Averages: Track your blood pressure trends over the last 7 days with dedicated morning and evening averages.
- Long-Term Evaluation: The app stores and analyzes data for a comprehensive long-term overview nempilo yakho.
8. Isondlo Nokunakekela
- Ukuhlanza: Wipe the device and cuff with a soft, dry cloth. If necessary, use a slightly damp cloth with a mild detergent, then wipe dry. Do not use abrasive cleaners or immerse the device in water.
- Isitoreji: Store the device in its provided storage bag/case in a cool, dry place, away from direct sunlight and extreme temperatures.
- Ukushintshwa Kwebhethri: Replace all batteries when the low battery indicator appears on the display. Dispose of used batteries according to local regulations.
- Ukunakekelwa Kwe-Cuff: The cuff is durable and reusable. Avoid bending the air tube excessively or subjecting the cuff to sharp objects.
9. Ukuxazulula izinkinga
| Inkinga | Imbangela Engenzeka | Isixazululo |
|---|---|---|
| Idivayisi ayivuli. | Amabhethri afile noma afakwe ngokungalungile. | Check battery polarity. Replace all 4 AAA batteries. |
| Umlayezo othi "Iphutha" uboniswa. | Ukugoba akusebenzi kahle, ukunyakaza ngesikhathi sokulinganisa, noma ukuvuza komoya. | Reapply cuff snugly. Remain still and quiet. Check air tube connection. Try again. |
| Ukufundwa okungahambisani. | Improper preparation (not rested), incorrect cuff placement, or external factors. | Ensure 5 minutes rest before measurement. Verify cuff position. Avoid talking/moving. Take multiple readings and average them. |
| Izinkinga zokuxhumeka kwe-Bluetooth. | Bluetooth off on phone, app not open, or device not paired. | Ensure Bluetooth is on. Open Veroval medi.connect app. Follow app instructions to pair device. |
| Arrhythmia symbol appears frequently. | Actual irregular heartbeat or movement during measurement. | Consult your doctor if this symbol appears consistently. Ensure you are completely still during measurement. |
10. Imininingwane Yezobuchwepheshe
| Ukucaciswa | Imininingwane |
|---|---|
| Igama Lemodeli | Veroval duo control |
| Inombolo Yemodeli | 5226 |
| Ibhrendi | VEROVAL (Paul Hartmann) |
| Indlela Yokukala | DUO SENSOR (Oscillometric and Korotkoff) |
| Uhlobo lwe-Cuff | Secure-Fit Arm Cuff |
| Usayizi weCuff | M (22-32 cm arm circumference) |
| Amandla enkumbulo | 200 measurements (100 per user for 2 users) |
| Umthombo wamandla | 4 x AAA 1.5V Batteries (included) |
| Ukuxhumana | Bluetooth (for Veroval medi.connect app) |
| Ubukhulu bomkhiqizo (L x W x H) | Okusondele. 24.5 x 17 x 8.2 cm |
| Ubukhulu bephakheji | 24.3 x 17.3 x 8.5 cm |
| Isisindo | 840 grams (including packaging) |
| Okubalulekile | Reusable, Durable |
| Izingxenye Ezihlanganisiwe | Monitor, Cuff, Storage Bag, Batteries, USB Cable |
11. Iwaranti kanye Nokusekela
The Veroval duo control blood pressure monitor is manufactured by Paul Hartmann AG. For information regarding warranty coverage, technical support, or service, please refer to the warranty card included in your package or visit the official VEROVAL webindawo.
Kunconywa ukuthi ugcine irisidi lakho lokuthenga njengobufakazi bokuthenga kwezimangalo zewaranti.
Umkhiqizi: Inkampani engu-PAUL HARTMANN AG
For further assistance, you may also contact the retailer where the product was purchased.