Sharp 201121A

Sharp #201121A Upper Knife Instruction Manual

For Overlock Sewing Machines: Juki, Pegasus, Siruba, Yamata

1. Umkhiqizo Uphelileview

The Sharp #201121A Upper Knife is a precision-engineered replacement part designed for various industrial overlock sewing machines. This component is crucial for the cutting mechanism, ensuring clean and consistent fabric trimming during the overlocking process. Proper installation and maintenance are essential for optimal machine performance and stitch quality.

This upper knife is compatible with a range of popular overlock machine brands, including Juki, Pegasus, Siruba, and Yamata, specifically fitting Pegasus M700 series overlock machines.

2. Ulwazi Lokuphepha

Always prioritize safety when working with sewing machines and sharp components. Failure to follow safety guidelines can result in injury or damage to the machine.

3. Ukuhambisana

The Sharp #201121A Upper Knife is designed for use with various industrial overlock sewing machines. Verify your machine's model number against the following compatibility list:

Always cross-reference the part number #201121A with your machine's manual or existing knife to ensure a correct fit.

4. Ukufakwa (Ukusethwa)

Replacing the upper knife requires careful attention to detail. Refer to your specific sewing machine's service manual for precise, model-specific instructions. The following steps provide a general guide:

  1. Cisha ugesi: Ensure the sewing machine is turned off and unplugged from the power outlet.
  2. Access Knife Area: Open the front cover or access panel of your overlock machine to expose the knife assembly.
  3. Remove Old Knife: Locate the screws holding the upper knife in place. Using an appropriate screwdriver, carefully loosen and remove these screws. Gently remove the old upper knife.
  4. Indawo Ehlanzekile: Clean any lint, dust, or debris from the knife mounting area using a brush or compressed air.
  5. Install New Knife: Position the new Sharp #201121A Upper Knife into its designated slot. Ensure it is seated correctly and aligned with the lower knife.
  6. Secure Knife: Insert and tighten the retaining screws. Do not overtighten, but ensure the knife is firmly secured and does not wobble.
  7. Adjust Knife Position (if necessary): Some machines may require fine adjustment of the upper knife's height or alignment relative to the lower knife for optimal cutting. Consult your machine's manual for specific adjustment procedures.
  8. Umsebenzi Wokuhlola: Close the machine's covers, plug it in, and perform a test run with scrap fabric to verify proper cutting action and stitch formation.
Sharp #201121A Upper Knife for Overlock Sewing Machines

Figure 1: The Sharp #201121A Upper Knife. This image displays the metal upper knife, featuring the part number "201121A" etched on its surface and a mounting hole. The knife has a distinct L-shaped cutting edge designed for overlock sewing machines.

5. Isondlo

Regular maintenance of the upper knife and surrounding area will prolong its lifespan and ensure consistent cutting performance.

6. Ukuxazulula izinkinga

If you experience issues after installing the new upper knife, consider the following:

For persistent issues, consult your overlock machine's specific service manual or contact a qualified sewing machine technician.

7. Imininingwane

Inombolo Yengxenye#201121A
Uhlobo LomkhiqizoUpper Knife
UkuhambisanaJuki, Pegasus (M700 series), Siruba, Yamata Overlock Sewing Machines
OkubalulekileMetal (Precision Steel)
UbukhuluApproximately 3 x 2 x 1.5 inches (as per product specifications)
IsisindoCishe ama-ounces angu-0.64

8. Iwaranti kanye Nokusekela

Information regarding specific warranty terms for the Sharp #201121A Upper Knife is not provided in the product details. For warranty inquiries or technical support, please contact the retailer or the manufacturer, Sharp Sewing, directly. You may find their contact information on their official webisayithi noma ngemibhalo yakho yokuthenga.

For additional resources and support related to your overlock sewing machine, refer to the machine's original manufacturer's webindawo noma izikhungo zesevisi ezigunyaziwe.

Amadokhumenti Ahlobene - 201121A

Ngaphambiliview Sharp Aquos Crystal Back Panel Replacement Guide
A step-by-step guide from iFixit on how to replace the back panel of a Sharp Aquos Crystal smartphone. This guide focuses on the prerequisite steps for accessing the back panel.
Ngaphambiliview Sharp Aquos LC13B2UA Stand Replacement Guide
Step-by-step instructions for replacing the stand on a Sharp Aquos LC13B2UA television, including tools and procedures.
Ngaphambiliview Sharp Aquos LC13B2UA Fuse Replacement Guide
Step-by-step instructions for replacing fuses in a Sharp Aquos LC13B2UA television, including tools and detailed procedures for safe and effective repair.
Ngaphambiliview Sharp Aquos LC13B2UA Buttons Replacement Guide
Detailed step-by-step instructions for replacing the buttons on a Sharp Aquos LC13B2UA television. This guide covers necessary tools, disassembly, and reassembly procedures.
Ngaphambiliview Sharp Aquos Crystal SIM Card Replacement Guide
Step-by-step instructions for replacing the SIM card in a Sharp Aquos Crystal smartphone. Learn how to safely remove the back panel and access the SIM card slot.
Ngaphambiliview Sharp Aquos Crystal Screen Replacement Guide
Detailed step-by-step instructions for replacing the screen on a Sharp Aquos Crystal smartphone. Includes required tools and repair procedures.