Steinbach 040949

Incwadi Yomsebenzisi Yephampu Yesihlungi se-Steinbach SPS 50-1T

Imodeli: 040949

1. Isingeniso

This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Steinbach SPS 50-1T self-priming filter pump. Please read this manual thoroughly before operating the pump to ensure proper function and longevity of the product. This filter pump is designed for use with swimming pools up to approximately 22,000 liters water content.

2. Iziyalezo Zokuphepha

Okubalulekile: Always disconnect the pump from the power supply before performing any installation, maintenance, or cleaning tasks.

3. Umkhiqizo Uphelileview kanye Nezingxenye

The Steinbach SPS 50-1T is a self-priming filter pump equipped with a pre-filter and an integrated timer. Familiarize yourself with the main components:

Steinbach SPS 50-1T Filter Pump complete view

Umfanekiso 1: Sekukonke view of the Steinbach SPS 50-1T filter pump, showing the motor, pump housing, pre-filter, and control panel.

Close-up of pre-filter with hose connection

Umfanekiso 2: Okuningiliziwe view of the pre-filter assembly, showing the transparent lid and the hose connection point for the inlet.

Control panel of the Steinbach SPS 50-1T pump

Umfanekiso 3: The pump's control panel, featuring the ON/OFF button, TIMER button, and indicator lights for setting operational hours.

4. Ukusetha nokufakwa

  1. Ukubekwa: Position the pump on a firm, level surface, ideally below the water level of the pool for easier priming. Ensure it is protected from rain and direct sunlight.
  2. Izixhumanisi zeHose: Connect the pool's skimmer line to the pump's inlet (pre-filter side) and the return line to the pump's outlet. Use hoses with a diameter of Ø 32/38 mm. Secure all connections with hose clamps ukuvimbela ukuvuza.
    Pump inlet and outlet connections

    Umfanekiso 4: View of the threaded inlet and outlet ports on the pump, ready for hose adapters.

  3. Ukufaka ipompo: Before starting, ensure the pre-filter is filled with water. If the pump is above water level, it may require manual priming by filling the pre-filter chamber until water flows into the pump housing.
  4. Uxhumano lukagesi: Plug the pump into a grounded electrical outlet (230V). Ensure the outlet is protected by a Residual Current Device (RCD) for safety.

5. Iziqondiso Zokusebenza

Once installed and primed, the pump is ready for operation.

5.1 Ukusebenza Mathupha

5.2 Umsebenzi Wesibali sikhathi

The integrated timer allows for automated operation cycles.

  1. Ensure the pump is connected to power.
  2. Cindezela inkinobho TIMER button repeatedly to select the desired operating duration (e.g., 2, 4, 6, 8, 10, 12, 14, 16, 24 hours). The corresponding indicator light will illuminate.
  3. The pump will start and run for the selected duration, then automatically shut off.
  4. The timer cycle will repeat daily at the same time it was initially set. To reset the timer, unplug the pump for a few seconds and then plug it back in.

6. Isondlo

Ukugcinwa njalo kuqinisekisa ukusebenza kahle futhi kwandisa isikhathi sokuphila kwephampu yakho.

6.1 Cleaning the Pre-filter Basket

  1. Nqamula iphampu kumthombo wamandla.
  2. Close any valves to prevent water flow from the pool.
  3. Unscrew the transparent lid of the pre-filter.
  4. Remove the pre-filter basket and clean it thoroughly under running water.
  5. Inspect the O-ring seal on the lid for damage and ensure it is clean.
  6. Replace the basket, secure the lid, and open the valves.
  7. Re-prime the pump if necessary before restarting.
Pre-filter with lid removed

Umfanekiso 5: The pre-filter chamber with its transparent lid removed, showing the internal basket for debris collection.

6.2 Ubusika

7. Ukuxazulula izinkinga

InkingaImbangela EngenzekaIsixazululo
Ipompo ayiqaliNo power; tripped circuit breaker; motor overload.Check power connection; reset circuit breaker; allow motor to cool.
Iphampu liyahamba kodwa awekho amanzi agelezayoPump not primed; air leak in suction line; clogged pre-filter basket; closed valves.Prime the pump; check all connections for leaks; clean pre-filter; open all valves.
Ukugeleza kwamanzi okuncishisiwePartially clogged pre-filter; restricted suction or return lines; low water level in pool.Clean pre-filter; check and clear hoses; ensure adequate pool water level.
Umsindo owedluleleAir in pump; cavitation; motor bearing wear.Ensure pump is fully primed and no air leaks; check for obstructions in suction line; contact service if motor noise persists.

8. Imininingwane Yezobuchwepheshe

IsiciUkucaciswa
ImodeliSPS 50-1T (040949)
Ukunikezwa kwamandla kagesi230V / 50Hz
Ukusetshenziswa kwamandla250 Watts
Pump Power (Flow Rate)7,020 liters/hour (Q= 117 l/min)
Max. Pump Height (Head)7.5 amamitha
Uhlobo LwephampuSelf-priming with Pre-Filter
I-Hose ConnectionØ 32/38 mm
Izinga Lokushisa Lamanzi Eliphezulu35°C
Maximum Pool Size22,000 amalitha
Izinga LomsindoCishe. awu 70db
Izici EzihlanganisiweIsikhathi
Ubukhulu bomkhiqizo1 x 1 x 1 cm
Isisindo sento6 kg
OkubalulekileMetal (motor housing), Plastic (pump housing, pre-filter)

9. Iwaranti kanye Nokusekela

For warranty information, technical support, or spare parts, please refer to the documentation provided with your purchase or contact Steinbach customer service. Keep your proof of purchase for warranty claims.

You can find more information and contact details on the official Steinbach webindawo: www.steinbach.at