COTEK SP-3000-112

Incwadi Yomsebenzisi ye-Cotek SP-3000-112 High Frequency Pure Sine Wave Inverter

Model: SP-3000-112

1. Isingeniso

This manual provides essential information for the safe and efficient operation of your Cotek SP-3000-112 High Frequency Pure Sine Wave Inverter. This device converts 12V DC power from batteries into 120V AC power, suitable for a wide range of electronic appliances. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Ulwazi Lokuphepha

Failure to follow these safety instructions may result in electric shock, fire, serious injury, or death. Always exercise caution when working with electrical equipment.

Illustration of a battery with a recycling symbol
Always handle batteries with care and ensure proper disposal.
Hard hat, safety glasses, and gloves on a wooden surface
Gqoka imishini yokuzivikela efanele ngesikhathi sokufakwa nokulungiswa.

3. Umkhiqizo Uphelileview

3.1 Izici ezibalulekile

3.2 Inverter Components

Cotek SP-3000-112 Pure Sine Wave Inverter, front-side view
Umfanekiso 1: Sekukonke view of the Cotek SP-3000-112 Pure Sine Wave Inverter. This image shows the robust blue and grey casing, ventilation grilles, and the general form factor of the unit.
Rear panel of the Cotek SP-3000-112 Inverter showing AC outlet and controls
Umfanekiso 2: Rear panel of the inverter. Visible components include the hardwire AC output terminal, the main power switch (ON/OFF), LED indicators, DIP switches for settings, and an RJ45 port for remote control.
Front panel of the Cotek SP-3000-112 Inverter showing DC input terminals and cooling fan
Umfanekiso 3: Front panel of the inverter. This view highlights the heavy-duty DC input terminals (red for positive, black for negative), the chassis ground connection, and the cooling fan vents.
Close-up of the control panel on the Cotek SP-3000-112 Inverter
Umfanekiso 4: Okuningiliziwe view of the control panel. This section includes the LED indicators (Power, Fault, Overload), DIP switches for configuration, the RJ45 remote control port, and the green terminal for remote ON/OFF control.

4. Ukusetha nokufakwa

Proper installation is crucial for the safe and efficient operation of your inverter. Refer to local electrical codes and standards.

4.1 Ukubekwa

Izintambo

All wiring must comply with applicable electrical codes and be performed by a qualified electrician.

  1. Ukubeka phansi: Connect the inverter's chassis ground terminal to a reliable earth ground using appropriate gauge wire.
  2. Uxhumano Lokufaka lwe-DC:
    • Ensure the battery bank voltage 12VDC.
    • Use appropriately sized cables for the DC input to minimize voltage drop and ensure safety. Refer to cable sizing charts based on current and distance.
    • Connect the positive (+) terminal of the battery bank to the red (+) terminal on the inverter.
    • Connect the negative (-) terminal of the battery bank to the black (-) terminal on the inverter.
    • Install a DC-rated fuse or circuit breaker between the battery bank and the inverter's positive terminal, as close to the battery as possible.
  3. Ukuxhumeka Kokukhipha kwe-AC:
    • Connect your AC loads to the hardwire AC output terminal block.
    • Ensure the total load does not exceed the inverter's continuous power rating (3000W).
  4. Isilawuli kude (Uma uthanda): Connect the remote control unit to the RJ45 port or use the green terminal for external ON/OFF control if desired.

5. Iziqondiso Zokusebenza

5.1 Ukuvula / Ukuvula

  1. Ukuvula: Ensure all DC and AC connections are secure. Flip the main power switch on the inverter's rear panel to the 'ON' position. The Power LED indicator should illuminate.
  2. Ukucisha: Disconnect all AC loads from the inverter. Flip the main power switch to the 'OFF' position.

5.2 Izinkomba ze-LED

The inverter features 3-color LED status indicators on the control panel (refer to Figure 4) to provide operational feedback:

5.3 Izilungiselelo zokushintsha kwe-DIP

The DIP switches on the control panel allow for customization of certain inverter parameters, such as output voltage, frequency, and power saving mode. Refer to the detailed specifications table (Figure 5) or the product datasheet for specific configurations. Always adjust DIP switches when the inverter is powered off.

6. Isondlo

Regular maintenance ensures the longevity and reliable operation of your inverter.

7. Ukuxazulula izinkinga

This section provides solutions to common issues you might encounter. If the problem persists, contact customer support.

InkingaImbangela EngenzekaIsixazululo
I-inverter ayivuli.No DC input power; Loose battery connections; Blown DC fuse/breaker; Inverter switch OFF.Hlola ivolumu yebhethritage; Tighten connections; Replace fuse/reset breaker; Turn inverter switch ON.
Akukho okukhipha i-AC.Overload; Short circuit; Over-temperature shutdown; Low/High DC input voltage.Reduce AC load; Check for short circuits in wiring/appliances; Allow inverter to cool; Check battery voltage.
Yellow LED illuminated.Ivolumu yebhethri ephansitage warning; High temperature warning.Recharge batteries; Ensure adequate ventilation, reduce load.
Red LED illuminated / Inverter shut down.Overload; Short circuit; Over-temperature; Under/Over voltage.Identify and correct the fault (e.g., reduce load, fix short, allow cooling, check battery voltage), then restart the inverter.
Cooling fan runs constantly or loudly.High internal temperature due to heavy load or poor ventilation.Reduce load; Improve ventilation around the inverter.

8. Imininingwane

The following table outlines the technical specifications for the Cotek SP-3000 Series Pure Sine Wave Inverter, specifically for the SP-3000-112 model.

Detailed specifications table for Cotek SP-3000 series inverters
Umfanekiso 5: Technical specifications for the Cotek SP-3000 Series, including the SP-3000-112 model.
IsigabaIpharamithaI-SP-3000-112
OkukhiphayoI-AC Voltage100 / 110 / 115 / 120VAC ±5%
Amandla Alinganiselwe3000W
Surge Power (1 Sec.)6000W
Amandla Okukhipha Amakhulu (1 iminithi)3450W
I-Waveform ephumayoPure Sine Wave (THD<3%)
Imvamisa50 / 60 Hz ±0.5%
OkokufakaI-DC Voltage12VDC
Voltage Ibanga10.5 ~ 16.5VDC
Awukho Umthwalo Wamanje<3.0A@12VDC
Imodi Yokonga Amandla<0.4A@12VDC
Ukusebenza kahle (Ubuningi.)90%
UkuvikelwaInput Under - Voltage Ukuvikelwa10.5 ±0.3VDC
Input Under - Voltage I-alamu11.0 ±0.3VDC
Input Under - Voltage Ukubuyisela12.0 ±0.3VDC
Input Over - Voltage Ukuvikelwa16.5 ±0.3VDC
Input Over - Voltage Ukubuyisela14.5 ±0.3VDC
Ukugcwala OkuphumayoVala shaqa okukhiphayo voltage, qala kabusha ukuze ululame
Okukhiphayo kufushaneVala shaqa okukhiphayo voltage, qala kabusha ukuze ululame
ImveloITemp Esebenzayo.-20°C ~ +40°C
Isikhathi Sokugcina. & Nomswakama-30°C ~ +70°C, 10 ~ 95% RH
OkujwayelekileUbukhulu (W x H x D)442 x 214 x 102 mm (17.4 x 8.4 x 4.0 amayintshi)
Isisindo8.2kg (18.1 lbs)
UkupholisaIzinga lokushisa nomthwalo olawulwayo wokupholisa ifeni
Mechanical drawings with dimensions for Cotek SP-3000 series inverter
Umfanekiso 6: Mechanical drawings providing dimensional information for installation planning.

9. Iwaranti kanye Nokusekela

9.1 Ulwazi Lwewaranti

The Cotek SP-3000-112 Pure Sine Wave Inverter comes with a Iwaranti Yonyaka Ongu-2 Yomkhiqizi. Lesi siqinisekiso sihlanganisa amaphutha ezintweni zokwakha kanye nokusebenza ngaphansi kokusetshenziswa okuvamile. Sicela ugcine ubufakazi bakho bokuthenga izimangalo zewaranti.

9.2 Ukwesekwa Kwamakhasimende

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Cotek customer support through their official website or your point of purchase. Provide your model number (SP-3000-112) and a detailed description of the issue to expedite service.

Amadokhumenti Ahlobene - I-SP-3000-112

Ngaphambiliview COTEK SP Series Pure Sine Wave Inverter Incwadi Yomsebenzisi
Imanuwali ebanzi yomsebenzisi ye-COTEK SP Series Pure Sine Wave Inverters (SP-700 kuya ku-SP-4000). Funda mayelana nokufaka, ukusebenza, ukuphepha, ukucaciswa kobuchwepheshe, nezici ezithuthukile ezifana nokuphumayo kwe-sine wave nokuvikela okuqinile.
Ngaphambiliview COTEK SP Series Pure Sine Wave Inverter Incwadi Yomsebenzisi
Incwadi yomsebenzisi ephelele ye-COTEK SP Series Pure Sine Wave Inverters (SP-700, SP-1000, SP-1500, SP-2000, SP-3000, SP-4000). Ihlanganisa imininingwane, ukufakwa, ukusebenza, ukuphepha, kanye nokuxhumana kwe-RS-232 ukuze kuguqulwe amandla ngendlela ethembekile.
Ngaphambiliview I-COTEK SPT Series Pure Sine Wave Inverter ene-Transfer Switch - Isingeniso Somkhiqizo kanye Nemininingwane
A kafushane phezuview yochungechunge lwe-COTEK SPT Ama-Pure Sine Wave Inverters ane-Transfer Switch, achaza imininingwane yawo yobuchwepheshe, ukubukeka komkhiqizo, imihlahlandlela yokufaka, nolwazi lwewaranti lwamamodeli ahlukahlukene.
Ngaphambiliview Incwadi Yomsebenzisi ye-COTEK SE Series Pure Sine Wave Inverter (200W, 350W, 400W)
Comprehensive user manual for the COTEK SE Series Pure Sine Wave Inverters, covering models 200W, 350W, and 400W. This guide provides detailed information on safety precautions, product features, electrical specifications, installation procedures, operation, maintenance, troubleshooting, and warranty details.
Ngaphambiliview COTEK SK Series 1500W Pure Sine Wave Inverter User's Manual
Comprehensive user's manual for the COTEK SK Series 1500W Pure Sine Wave Inverter, covering safety, features, specifications, installation, operation, maintenance, and troubleshooting. Provides detailed guidance for proper use and care.
Ngaphambiliview COTEK SK120, SK200, SK350 Series Pure Sine Wave Inverter Manual User
Le manuwali yomsebenzisi ihlinzeka ngemininingwane enemininingwane yochungechunge lwe-COTEK SK120, SK200, kanye ne-SK350 ehlanzekile ye-sine wave inverters, ehlanganisa ukuphepha, izici, ukufakwa, ukusebenza, ukuxazulula izinkinga, kanye newaranti.