Sealey MM20HV

Incwadi Yemiyalelo Ye-Sealey MM20HV Digital Multimeter

Model: MM20HV

1. Isingeniso

This manual provides detailed instructions for the safe and effective use of your Sealey MM20HV Digital Multimeter. The MM20HV is a heavy-duty, general-purpose multimeter designed for various electrical measurements, featuring a clear LCD display, data hold function, temperature probe, and diode test facility. It is housed in a rugged rubber boot with an integral stand for durability and convenience.

Sicela ufunde le ncwadi ngokucophelela ngaphambi kokusebenzisa idivayisi bese uyigcina ukuze uyibhekisele esikhathini esizayo.

2. Ulwazi Lokuphepha

Always observe basic safety precautions when using electrical testing equipment to reduce the risk of fire, electric shock, and personal injury.

  • Funda imiyalelo: Qonda yonke imiyalelo yokusebenza kanye nezixwayiso zokuphepha ngaphambi kokusebenzisa.
  • Hlola Idivayisi: Before each use, inspect the multimeter and test leads for any damage. Do not use if damaged.
  • Proper Range: Always select the correct function and range for the measurement.
  • Voltage Imikhawulo: Do not exceed the maximum input limits specified for each range.
  • Live Circuits: Never measure resistance, continuity, or diode on a live circuit. Ensure power is off and circuits are discharged.
  • I-Insulation: Keep fingers behind the probe barriers during measurements.
  • Imvelo: Do not use the multimeter in wet conditions or in the presence of explosive gases or fumes.
  • Ukusevisa: Refer all servicing to qualified personnel. Battery and fuse replacement are the only user-serviceable parts.

3. Yini EseBhokisini

Lapho ukhipha, qiniseka ukuthi zonke izinto ezibalwe ngezansi zikhona futhi azilimele:

  • Sealey MM20HV Digital Multimeter
  • Ama-Test Lead (Obomvu Nomnyama)
  • I-Thermocouple (I-Temperature Probe)
  • Incwadi Yomsebenzisi (le dokhumenti)
Sealey MM20HV Digital Multimeter with test leads and thermocouple

Umfanekiso 1: Sealey MM20HV Digital Multimeter shown with included test leads and thermocouple.

4. Setha

4.1. Ukufakwa kwebhethri

The Sealey MM20HV requires two AAA batteries for operation.

  1. Thola isembozo segumbi lebhethri ngemuva kwe-multimeter.
  2. Use a screwdriver to remove the screw securing the cover.
  3. Faka amabhethri amabili e-AAA, ubheke i-polarity efanele (+ kanye no-) njengoba kuboniswe ngaphakathi kwegumbi.
  4. Shintshanisa ikhava yekhompathi yebhethri futhi uyivikele ngesikulufu.

4.2. Ukuxhumanisa Abaholi Bokuhlola

Proper connection of test leads is essential for accurate and safe measurements.

  • Insert the black test lead into the "COM" (Common) jack.
  • Okweningi levolumutage, resistance, and continuity measurements, insert the red test lead into the "VΩmA" jack.
  • For high current (up to 10A DC) measurements, insert the red test lead into the "10A DC" jack. Ensure the function dial is set to the appropriate current range.
Sealey MM20HV Digital Multimeter with test leads connected

Umfanekiso 2: Multimeter with black lead in COM and red lead in VΩmA jack.

5. Iziqondiso Zokusebenza

The Sealey MM20HV offers 8 functions for various electrical measurements.

5.1. Vula/Vala

Rotate the central function dial from the "OFF" position to any desired measurement function to turn the multimeter on. To turn off, rotate the dial back to "OFF".

5.2. Measuring DC Voltage (V=)

  1. Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
  2. Set the function dial to the desired DC Voltagububanzi be-e (isb., 200mV, 2V, 20V, 200V, 600V). Uma ivolumutage is unknown, start with the highest range and decrease as necessary.
  3. Xhuma ama-test probes kulo lonke i-component noma i-circuit ezolinganiswa.
  4. Funda ivolumutage value kusibonisi se-LCD.

5.3. Ukulinganisa i-AC Voltage (V~)

  1. Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
  2. Set the function dial to the desired AC Voltagububanzi be-e (isb., 200V, 600V).
  3. Connect the test probes across the AC voltage umthombo.
  4. Funda ivolumutage value kusibonisi se-LCD.

5.4. Measuring DC Current (A=)

Isexwayiso: Ungalokothi uxhume i-multimeter ngesikhathi esifanayo ne-voltagumthombo lapho ulinganisa ugesi. Xhuma njalo ngochungechunge nomthwalo.

  1. Insert the black lead into the "COM" jack.
  2. For currents up to 200mA, insert the red lead into the "VΩmA" jack. For currents up to 10A, insert the red lead into the "10A DC" jack.
  3. Set the function dial to the appropriate DC Current range (e.g., 2mA, 20mA, 200mA, 10A).
  4. Open the circuit where current is to be measured and connect the multimeter in series.
  5. Funda inani lamanje kusibonisi se-LCD.

5.5. Measuring Resistance (Ω)

Isexwayiso: Qinisekisa ukuthi isekethe ayinamandla futhi wonke ama-capacitor ayakhishwa ngaphambi kokulinganisa ukumelana.

  1. Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
  2. Set the function dial to the desired Resistance range (e.g., 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ).
  3. Connect the test probes across the component whose resistance is to be measured.
  4. Funda inani lokumelana esibukweni se-LCD.

5.6. Ukuhlolwa Okuqhubekayo Okuzwakalayo

This function allows for quick checks of circuit continuity with an audible tone.

  1. Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
  2. Set the function dial to the continuity symbol (often shared with diode test).
  3. Xhuma ama-probe okuhlola kulo lonke isekethe noma ingxenye.
  4. An audible tone indicates continuity (low resistance). The display will show the resistance value.

5.7. Diode/Transistor Verification

This function allows for testing diodes and transistors.

  1. Insert the black lead into the "COM" jack and the red lead into the "VΩmA" jack.
  2. Set the function dial to the diode symbol.
  3. For diode testing, connect the red probe to the anode and the black probe to the cathode. The display will show the forward voltage drop. Buyisela emuva ama-probe; isibonisi kufanele sibonise "OL" (Open Loop) ukuze kube ne-diode enhle.
  4. For transistor (hFE) testing, insert the transistor leads into the appropriate NPN or PNP sockets on the multimeter. The display will show the hFE value.

5.8. Measuring Temperature (°C)

The multimeter includes a thermocouple for temperature measurements.

  1. Remove the test leads from the input jacks.
  2. Insert the thermocouple plug into the "VΩmA" and "COM" jacks, observing polarity if indicated.
  3. Set the function dial to the "°C" range.
  4. Place the tip of the thermocouple on or near the object whose temperature is to be measured.
  5. Read the temperature value in Celsius on the LCD display.

5.9. Data Hold Function

Press the "HOLD" button (typically a green button on the front panel) to freeze the current reading on the display. Press it again to release the hold and resume live readings.

6. Isondlo

6.1. Ukuhlanza

Sula ikesi ngesikhangisoamp cloth and mild detergent. Do not use abrasives or solvents. Ensure the device is off and disconnected from any circuits before cleaning.

6.2. Ukushintshwa Kwebhethri

When the battery indicator appears on the display, replace the batteries as described in Section 4.1. Always use fresh AAA batteries.

6.3. Ukushintshwa kwe-Fuse

If the current measurement function stops working, the fuse may need replacement.

  1. Qinisekisa ukuthi i-multimeter icishiwe futhi wonke ama-test lead anqanyuliwe.
  2. Remove the battery compartment cover and batteries.
  3. Locate the fuse(s) inside the compartment. The MM20HV typically uses a 200mA/250V fast-blow fuse for the mA range and a 10A/250V fast-blow fuse for the 10A range.
  4. Carefully remove the old fuse and replace it with a new fuse of the exact same type and rating.
  5. Replace the batteries and battery compartment cover.

Okubalulekile: Never use a fuse with a different rating or bypass a fuse. This can damage the multimeter and pose a serious safety hazard.

7. Ukuxazulula izinkinga

InkingaImbangela EngenzekaIsixazululo
Asikho isibonisi noma isibonisi esifipheleAmabhethri afile noma aphansiReplace batteries (Section 4.1)
Ukufundwa okungalungileIncorrect range selected, poor lead connection, damaged leadsSelect appropriate range, ensure leads are fully inserted, inspect leads for damage and replace if necessary
Ukulinganisa kwamanje akusebenziI-fuse eshaywayoReplace fuse (Section 6.3)
"OL" (Ukulayisha ngokweqile) kubonisiweMeasurement exceeds selected range, open circuit (for resistance/continuity)Select a higher range, check circuit for breaks

8. Imininingwane

The following table outlines the technical specifications for the Sealey MM20HV Digital Multimeter.

UkucaciswaInani
Imodeli No.I-MM20HV
IbhrendiSealey
Imisebenzi8 (AC/DC Voltage, DC Current, Resistance, Temperature, Audible Continuity, Diode/Transistor Verification)
I-AC Voltage (Accuracy)200V, 600V (±2%)
I-DC Voltage (Accuracy)200mV, 2V, 20V, 200V, 600V (±0.5% to ±0.8%)
DC Current (Accuracy)2mA, 20mA, 200mA, 10A (±1% to ±2%)
Resistance (Accuracy)200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ (±0.8% to ±1%)
Izinga LokushisaUp to 1000°C (with thermocouple)
Umthombo wamandla2 x AAA Amabhethri
Isisindo sento0.29 Amakhilogremu (cishe ama-ounces angu-10.2)
Ubukhulu (L x W x H)1.97 x 4.33 x 6.18 amayintshi
Izinga LokuphephaI-IEC 1010

Qaphela: Imininingwane ingashintsha ngaphandle kwesaziso.

9. Iwaranti kanye Nokusekela

For information regarding warranty coverage, technical support, or service, please refer to the warranty card included with your product or contact Sealey customer service directly. Contact details are typically available on the manufacturer's official webindawo.

Amadokhumenti Ahlobene - I-MM20HV

Ngaphambiliview Incwadi Yomsebenzisi Yokuhlaziya Izimoto Zedijithali yeSealey TA101 12
Incwadi yomsebenzisi ephelele ye-Sealey TA101 12 Function Digital Automotive Analyser. Ichaza izinyathelo zokuphepha, imininingwane yobuchwepheshe, izinqubo zokusebenza zokulinganisa okuhlukahlukene, ukulungiswa, kanye nokuxazulula izinkinga.
Ngaphambiliview Sealey TM102 8-Function Professional Auto-Ranging Digital Multimeter - User Manual
Comprehensive user manual for the Sealey TM102 8-Function Professional Auto-Ranging Digital Multimeter. Includes safety instructions, specifications, operation guide, and maintenance procedures.
Ngaphambiliview Incwadi Yomsebenzisi ye-Sealey MM19.V3 7-Function Digital Multimeter
Incwadi yomsebenzisi ephelele ye-Sealey MM19.V3 7-Function Digital Multimeter, echaza imiyalelo yokuphepha, imininingwane, izici, kanye nokusebenza kwe-AC/DC voltagi-e, i-DC current, ukumelana, ukuqhubeka, kanye nokulinganiswa kwe-transistor.
Ngaphambiliview I-Heavy-Duty Mobile Tool & Parts Trolley enamadrawer ama-5 kanye nePhezulu Elikhiyayo - Sealey AP890MHV
Imiyalo nokucaciswa kwethuluzi leselula le-Sealey AP890MHV nezingxenye zetroli. Izici zifaka amadrowa angu-5 anamaslayidi anebhola, isivalo esingaphezulu esikhiyekayo, kanye nomklamo obonakala kakhulu.
Ngaphambiliview Sealey RS1312HV 900A 12V RoadStart Emergency Jump Starter - Hi-Vis Green User Manual
Comprehensive user manual for the Sealey RS1312HV 900A 12V RoadStart Emergency Jump Starter. Includes safety instructions, specifications, features, operation guide, charging procedures, troubleshooting, and battery recycling information.
Ngaphambiliview I-Sealey 1050CXLE v3 Trolley Jack Hydraulic Oil Safety Data Sheet
Ishidi Ledatha Yokuphepha le-Sealey 1050CXLE v3 Trolley Jack 2 Tonne Low Profile I-Chassis emfushane Uwoyela weHydraulic, echaza ukuhlonza umkhiqizo, izingozi, usizo lokuqala, ukulwa nomlilo, ukuphatha, ukugcinwa, izakhiwo ezibonakalayo, nokulahlwa.