1. Umkhiqizo Uphelileview

The Fantech EDF7 Electronic Multifunction Dehumidistat is designed for use with all Fantech HRV/ERV units, with the exception of the SH/VH 704 models. This advanced control offers three distinct modes of operation: ventilation, recirculation, and standby, providing comprehensive air quality management for your space.

Key features of the EDF7 Dehumidistat include:

Fantech EDF7 Electronic Multifunction Dehumidistat front panel

Umfanekiso 1: Ngaphambili view of the Fantech EDF7 Electronic Multifunction Dehumidistat. The control panel features an upper section for 'OVERRIDE CONTROLS' including humidity adjustment buttons and a digital display for humidity. The lower section, 'MODE CONTROLS', includes buttons for Power, Modes, Mode Speed, and Cycle, along with indicators for filter status and various operational states.

2. Ukufakwa kanye nokusetha

The Fantech EDF7 Dehumidistat is designed for wall-mounted installation and requires connection to a compatible Fantech HRV/ERV unit. For optimal performance and safety, it is highly recommended that installation be performed by a qualified HVAC professional or a certified electrician.

2.1 Uhlu Lokuhlola Lokufaka Ngaphambi Kokufaka

2.2 Izintambo Iziyalezo

Refer to the wiring diagram provided with your Fantech HRV/ERV unit and the EDF7 packaging for specific connection points. Generally, the dehumidistat connects to the low-voltage control terminals of the HRV/ERV unit. Ensure all connections are secure and follow local electrical codes.

Qaphela: Incorrect wiring can damage the unit or pose a safety hazard. If unsure, consult a professional.

2.3 Ukwenyusa Amandla Okuqala

After installation and wiring are complete, restore power to the HRV/ERV unit. The EDF7's LED backlit screen should illuminate, displaying the current indoor relative humidity.

3. Iziqondiso Zokusebenza

The EDF7 Dehumidistat provides intuitive control over your ventilation system. Familiarize yourself with the control panel as shown in Figure 1.

3.1 Ukuvula / Ukuvula

3.2 Ukukhetha Izindlela Zokusebenza

The EDF7 offers three primary operating modes:

To change modes, press the IMODES button (located next to the Power button) repeatedly until the desired mode indicator illuminates on the display.

3.3 Adjusting Humidity Set Point

The dehumidistat allows you to set a desired relative humidity level. When the indoor humidity exceeds this set point, the unit will activate to reduce humidity.

3.4 Ukulawula isivinini sabalandeli

The EDF7 offers four fan speed settings:

To adjust the fan speed, press the MODE SPEED button (located in the lower section) repeatedly until the indicator for the desired speed is lit.

3.5 Summer Setting

During summer months when dehumidification is not required, you can activate the Summer setting to prevent the unit from operating based on humidity levels.

3.6 Override Controls

The upper section of the control panel features override controls, allowing for temporary adjustments or activation of specific functions regardless of the current mode or humidity settings. These typically include timed boosts or specific cycle activations. Refer to your HRV/ERV unit's comprehensive manual for detailed use of these override functions.

4. Isondlo

Regular maintenance ensures the longevity and optimal performance of your Fantech EDF7 Dehumidistat and connected HRV/ERV system.

4.1 Cleaning the Dehumidistat

4.2 Filter Maintenance (HRV/ERV Unit)

The EDF7 control panel includes a ISIHLUNGI indicator (as seen in Figure 1). This light illuminates to remind you to check and clean or replace the filters in your connected Fantech HRV/ERV unit. Refer to your HRV/ERV unit's manual for specific filter maintenance procedures and schedules.

Okubalulekile: Neglecting filter maintenance can reduce system efficiency and air quality.

5. Ukuxazulula izinkinga

If you experience issues with your Fantech EDF7 Dehumidistat, try the following common troubleshooting steps. For more complex issues, consult a qualified technician.

InkingaImbangela EngenzekaIsixazululo
Dehumidistat display is off.No power to the unit or HRV/ERV.Check the circuit breaker for the HRV/ERV unit. Ensure the dehumidistat is properly wired. Press the AMANDLA inkinobho.
Unit not responding to humidity settings.Summer setting active; incorrect humidity set point; HRV/ERV unit malfunction.Deactivate Summer setting. Adjust humidity set point lower than current indoor humidity. Consult HRV/ERV manual for troubleshooting its operation.
Fan speed not changing.Incorrect button press; HRV/ERV unit issue.Qinisekisa ukuthi ucindezela inkinobho MODE SPEED button. Check HRV/ERV unit for errors or blockages.
FILTER indicator light is on.HRV/ERV filters are dirty or need replacement.Clean or replace the filters in your Fantech HRV/ERV unit as per its manual. Reset the filter indicator if applicable (refer to HRV/ERV manual).

6. Imininingwane Yomkhiqizo

IsiciImininingwane
Inombolo YemodeliI-EDF7
IbhrendiI-FANTECH
UkuhambisanaAll Fantech HRV/ERV units (except SH/VH 704)
Amamodi OkusebenzaVentilation, Recirculation, Standby
Inombolo Yezivinini4 (Low, Medium, Normal, 20 min/hr)
BonisaLED Backlit, displays Indoor Relative Humidity
UmbalaEmhlophe
Izingxenye EzihlanganisiweIsilawuli
Ubukhulu bephakheji5.51 x 4.41 x 1.65 amayintshi
Isisindo sento4.94 amakhilogremu
I-UPC650737448837

7. Ulwazi Lwewaranti

Specific warranty terms and conditions for the Fantech EDF7 Electronic Multifunction Dehumidistat are provided by the manufacturer. Please refer to the warranty card included with your product packaging or visit the official Fantech website for detailed warranty coverage, duration, and claim procedures.

Qaphela: Gcina ubufakazi bakho bokuthenga ngezimangalo zewaranti.

8. Ukwesekwa Kwamakhasimende

For technical assistance, replacement parts, or further inquiries regarding your Fantech EDF7 Dehumidistat, please contact Fantech customer support.

When contacting support, please have your product model number (EDF7) and purchase date available.