1. Isingeniso
This manual provides detailed instructions for the installation, operation, and maintenance of the Cotek SP-1000-224 Pure Sine Wave Inverter. This inverter is designed to convert 24VDC power to 230VAC, providing a stable and reliable power source for various applications.
Izici Eziyinhloko:
- Pure sine wave output for sensitive electronics.
- Power ON / OFF remote control capability (Green Terminal).
- Input & output fully isolated for enhanced safety.
- Temperature & load controlled cooling fan for optimal performance.
- Isixhumi esibonakalayo esisebenziseka kalula.
- Output frequency (50/60 Hz) selectable via DIP switch.
- Umphumela voltage selectable via DIP switch.
- Power saving mode adjustable via variable resistor.
- 3-color LED status indicators for easy monitoring.
- Comprehensive input protection: Reverse Polarity (Fuse), Under Voltage, Ngaphezulu Voltage.
- Robust output protection: Short Circuit, Overload, Over Temperature.
- Type 1 Indoor Aluminum Enclosure.
- E13 / UL / CE / FCC approved.
2. Ulwazi Lokuphepha
WARNING: Please read and understand all safety instructions before installing or operating this inverter. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.
- Ingozi kagesi: This unit produces high voltage. Do not open the inverter casing. Thumela zonke izinsiza kubasebenzi abaqeqeshiwe.
- Ukuphepha Kwebhethri: Work in a well-ventilated area. Batteries can produce explosive gases. Do not smoke or allow sparks or flames near the battery.
- I-Ventilation efanele: Ensure adequate airflow around the inverter. Do not block ventilation openings.
- Izimo Zemvelo: Do not expose the inverter to rain, moisture, or excessive dust. Operate in a dry, cool environment.
- Ukubeka phansi: The inverter must be properly grounded. Follow all local and national electrical codes.
- Amandla okulayisha: Do not exceed the inverter's rated power output. Overloading can cause damage to the inverter and connected devices.
- Isexwayiso se-California Proposition 65: Lo mkhiqizo ungase uqukathe izinto ezixwayiswe yi-California Proposition 65.
3. Umkhiqizo Uphelileview kanye Nezingxenye
Familiarize yourself with the various parts of your Cotek SP-1000-224 Pure Sine Wave Inverter.

Umfanekiso 3.1: I-engeli view of the Cotek SP-1000-224 Pure Sine Wave Inverter, showing its blue aluminum casing and grey end caps with ventilation and connection ports.

Umfanekiso 3.2: Front panel of the inverter, featuring the AC output socket (Schuko type), a power switch, LED indicators, and DIP switches for configuration.

Umfanekiso 3.3: Rear panel of the inverter, showing the DC input terminals for battery connection, a remote control port (RJ45), and a green terminal block for remote ON/OFF control.

Umfanekiso 3.4: Side view of the inverter, highlighting its robust blue aluminum heat sink casing designed for efficient heat dissipation.

Umfanekiso 3.5: A detailed table outlining the features and technical specifications of the Cotek SP-1000 series inverters, including input/output parameters, protections, and certifications.

Umfanekiso 3.6: Mechanical drawings providing dimensions of the inverter, along with power voltage and power temperature curves illustrating performance characteristics.
4. Ukusetha nokufakwa
4.1 Ukukhetha Indawo:
- Install the inverter in a dry, cool, and well-ventilated area.
- Avoid direct sunlight, heat sources, and moisture.
- Ensure sufficient clearance around the inverter for proper airflow, especially around the cooling fan and ventilation openings.
- Mount the inverter securely on a stable, non-combustible surface.
4.2 DC Input Connection:
- Qinisekisa ukuthi iswishi yamandla ye-inverter isesimweni se-OFF.
- Connect the positive (+) terminal of the 24VDC battery bank to the positive (+) DC input terminal on the inverter.
- Connect the negative (-) terminal of the 24VDC battery bank to the negative (-) DC input terminal on the inverter.
- Use appropriately sized cables to minimize voltage drop and ensure safe operation. Refer to electrical standards for cable sizing.
- Qinisekisa ukuthi konke ukuxhumana kuqinile futhi kuvikelekile.
4.3 Ukuxhumeka Kokukhipha kwe-AC:
- Plug your AC appliances directly into the AC output socket on the inverter.
- Ensure the total power consumption of all connected appliances does not exceed the inverter's 1000W continuous output rating.
4.4 Ukubeka phansi:
Proper grounding is essential for safety. Connect the inverter's chassis ground terminal to a reliable earth ground using a suitable grounding wire. Consult local electrical codes for specific grounding requirements.
4.5 Remote Control (Optional):
The inverter supports remote ON/OFF control via the green terminal block or an optional RJ45 remote control unit. Refer to the accessory manual for detailed instructions on connecting and using the remote control.
4.6 DIP Switch Configuration:
The inverter features DIP switches on the front panel to select output frequency (50/60 Hz) and output voltage. Refer to the table below for common settings. Ensure the inverter is OFF before changing DIP switch settings.
| Ukusetha | Isikhundla Sokushintsha I-DIP |
|---|---|
| Imvamisa Yokukhipha 50Hz | Switch 1: OFF, Switch 2: OFF (Example, refer to actual product manual/Figure 3.5) |
| Imvamisa Yokukhipha 60Hz | Switch 1: ON, Switch 2: OFF (Example, refer to actual product manual/Figure 3.5) |
| Okukhipha Umqtage230VAC | Switch 3: ON, Switch 4: OFF (Example, refer to actual product manual/Figure 3.5) |
Note: The exact DIP switch configurations for specific voltage and frequency settings are detailed in the product's full technical specifications (refer to Figure 3.5). Always verify settings before operation.
5. Ukusebenza
5.1 Powering On the Inverter:
- Ensure all DC and AC connections are secure and correct.
- If using the remote control, ensure it is connected and in the ON position.
- Flip the main power switch on the inverter's front panel to the "ON" position.
- Observe the 3-color LED status indicators. A green light indicates normal operation.
5.2 LED Status Indicators:
- Okuluhlaza: Ukusebenza okuvamile.
- Okuphuzi/I-Amber: Warning (e.g., input voltage slightly low/high, minor overload). The inverter may continue to operate but requires attention.
- Okubomvu: Fault condition (e.g., severe overload, short circuit, over-temperature, critical input voltage). The inverter will shut down to protect itself and connected devices.
5.3 Power Saving Mode:
The inverter features a power saving mode, adjustable via a variable resistor. This mode reduces power consumption when no load or a very light load is detected. Adjust the resistor to set the sensitivity for entering/exiting power saving mode.
5.4 Powering Off the Inverter:
- Turn off all connected AC appliances.
- Flip the main power switch on the inverter's front panel to the "OFF" position.
- If using a remote control, turn it off as well.
6. Isondlo
Regular maintenance ensures the longevity and reliable operation of your inverter.
- Ukuhlanza: Periodically clean the exterior of the inverter with a dry, soft cloth. Do not use liquid cleaners or solvents. Ensure ventilation openings are free from dust and debris.
- Izixhumanisi: Periodically check all DC and AC connections to ensure they are tight and free from corrosion. Loose connections can cause overheating and poor performance.
- Ukungenisa umoya: Ensure the cooling fan and ventilation grilles are not obstructed. The fan operates based on temperature and load, so ensure it can draw and expel air freely.
- Impilo Yebhethri: Monitor the health of your battery bank. A weak or failing battery can negatively impact inverter performance and lifespan.
WARNING: Do not attempt to service the inverter yourself. There are no user-serviceable parts inside. Refer all servicing to qualified personnel.
7. Ukuxazulula izinkinga
This section provides solutions to common issues you might encounter with your inverter. If the problem persists after following these steps, contact customer support.
| Inkinga | Imbangela Engenzeka | Isixazululo |
|---|---|---|
| Inverter does not turn on (No LED indication) |
|
|
| Red LED is on, inverter shuts down |
|
|
| Yellow/Amber LED is on |
|
|
| Akukho okukhiphayo kwe-AC |
|
|
8. Imininingwane Yezobuchwepheshe
The following table provides detailed technical specifications for the Cotek SP-1000-224 Pure Sine Wave Inverter. For a comprehensive overview, refer to Figure 3.5.
| Ipharamitha | Value (SP-1000-224) |
|---|---|
| Imodeli | I-SP-1000-224 |
| Umkhiqizo we-AC Voltage | 230VAC (selectable) |
| Okokufaka kwe-DC Voltage | 24VDC |
| Amandla Aqhubekayo | 1000W |
| Surge Power (3 sec) | 1750VA |
| I-Waveform ephumayo | I-Pure Sine Wave (THD <3%) |
| Imvamisa Yokuphuma | 50/60 Hz (kuyakhetheka) |
| Efficiency (Max) | 92% |
| Okokufaka Ngaphansi Kwevolumutage Ukuvikelwa | 21.0 ± 0.5VDC |
| Okokufaka ngaphezulu kwevoltage Ukuvikelwa | 33.0 ± 0.5VDC |
| Izinga Lokushisa Lokusebenza | -20°C ~ +40°C (60% power load) |
| Ubukhulu (L x W x H) | 17 x 10 x 6 amayintshi (cishe.) |
| Isisindo | 8.94 amakhilogremu |
| Izitifiketi | I-E13 / UL / CE / FCC ivunyelwe |
Note: Specifications are subject to change without notice. Always refer to the product label or manufacturer's official documentation for the most accurate and up-to-date information.
9. Ulwazi Lwewaranti
COTEK products are manufactured to high quality standards. For specific warranty terms and conditions, including duration and coverage, please refer to the warranty card included with your product or visit the official COTEK webindawo. Gcina ubufakazi bakho bokuthenga ngezimangalo zewaranti.
Typical warranties cover defects in materials and workmanship under normal use. Damage caused by improper installation, misuse, abuse, or unauthorized modifications is generally not covered.
10. Ukwesekwa Kwamakhasimende
If you have any questions, require technical assistance, or need to report an issue with your Cotek SP-1000-224 Pure Sine Wave Inverter, please contact COTEK customer support or your authorized dealer.
Uma uxhumana nosekelo, sicela ube nolwazi olulandelayo olulungile:
- Product Model: SP-1000-224
- Serial Number (if applicable, usually found on the product label)
- Usuku Lokuthenga
- A detailed description of the issue you are experiencing.
For the most up-to-date contact information, please visit the official COTEK webindawo: www.cotek.com.tw (This is a placeholder URL, please verify the actual manufacturer webindawo).