1. Isingeniso
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Steinbach 040955 CPS 40-2 Filtration Pump. Please read these instructions carefully before using the pump to ensure proper function and longevity of the product. This pump is designed for filtering pool water up to approximately 19,000 liters capacity and is compatible with Steinbach Classic 300, Classic 250, and ActiveBalls+ filtration systems.
2. Iziyalezo Zokuphepha
Always observe the following safety precautions to prevent injury or damage to the pump.
- Ukuphepha Kagesi: Ensure the power supply matches the pump's specifications (240 Volts). Always disconnect the pump from the power supply before performing any maintenance or cleaning. Do not operate the pump with a damaged power cord or plug.
- Ukuphepha Kwamanzi: Never operate the pump dry. Ensure the pump is fully primed with water before starting. Keep children and pets away from the pump during operation.
- Ukubekwa: Install the pump on a stable, level surface. Ensure adequate ventilation around the pump to prevent overheating.
- Izinga lokushisa: The pump is designed for water temperatures up to 35 degrees Celsius.
3. Umkhiqizo Uphelileview
The Steinbach 040955 CPS 40-2 is a robust filtration pump designed for efficient pool water circulation. It features a durable plastic housing and an electric cable power source. The pump is compact and operates quietly.

Umfanekiso 3.1: Ngaphambili view of the Steinbach 040955 CPS 40-2 Filtration Pump.

Umfanekiso 3.2: Uhlangothi view of the pump, showing the inlet and outlet connections.

Figure 3.3: Visual representation of the pump's dimensions, approximately 20 cm (8.2 inches) in height.

Figure 3.4: Product packaging displaying key specifications such as 230V/200W power, 6.5m max head, and 6000 l/h flow rate.
4. Setha
Follow these steps for proper installation of your filtration pump:
- Ukukhulula: Susa ngokucophelela zonke izingxenye ephaketheni. Hlola noma yimuphi umonakalo.
- Ukubekwa: Position the pump on a firm, level surface near your pool, ensuring it is protected from direct weather exposure and has adequate air circulation.
- Izixhumanisi zeHose: Connect the appropriate hoses (32mm or 38mm diameter) to the pump's inlet and outlet ports. Ensure all connections are secure and watertight to prevent leaks.
- I-Priming: Before starting, ensure the pump is fully primed with water. This typically involves filling the pump housing with water until it overflows from the suction port.
- Uxhumano lukagesi: Connect the pump to a grounded electrical outlet (240V). Ensure the circuit is protected by a Residual Current Device (RCD) for safety.
5. Ukusebenza
Once the pump is set up and primed, you can begin operation:
- Ukuqala i-Pump: Turn on the power supply to the pump. The pump should start circulating water immediately.
- Ukuqapha: Observe the water flow and pressure. The pump operates quietly, indicating efficient performance.
- Isikhathi Sokuqalisa: The optimal run time for your pump depends on your pool size and usage. Consult your pool system's guidelines for recommended daily filtration cycles.
- Iyavala: To turn off the pump, simply disconnect it from the power supply.
6. Isondlo
Regular maintenance ensures the longevity and efficiency of your filtration pump:
- Ukuhlanza: Periodically clean the pump's exterior with a damp indwangu. Ungasebenzisi amakhemikhali anokhahlo.
- Filter System Maintenance: This pump works in conjunction with a filtration system. Regularly clean or replace the filter cartridges or media as recommended by your filter system's manual.
- Ukwenza ubusika: If you live in an area with freezing temperatures, disconnect the pump and drain all water from it before winter. Store the pump in a dry, frost-free location.
- Ukuhlolwa kweHose: Regularly check hoses and connections for wear, cracks, or leaks. Replace damaged components as needed.
7. Ukuxazulula izinkinga
Uma uhlangabezana nezinkinga ngephampu yakho, bheka izinkinga nezixazululo ezilandelayo ezivamile:
| Inkinga | Imbangela Engenzeka | Isixazululo |
|---|---|---|
| Ipompo ayiqali | Akukho ukunikezwa kwamandla Ukushisisa kwezimoto I-impeller ijamekile | Hlola ukuxhumeka kwamandla kanye ne-circuit breaker Allow pump to cool down Disconnect power and inspect/clear impeller |
| Ukugeleza kwamanzi aphansi | Ipompo ayinconyiwe Isihlungi esivaliwe Ukuvuza komoya kulayini wokumunca | Qalisa kabusha iphampu Hlanza noma shintsha isihlungi Hlola konke ukuxhunywa kwelayini yokuncela ukuze kuqine |
| Iphampu linomsindo | Umoya ohlelweni Imfucumfucu ku-impeller Iphampu yomile | Wopha umoya ohlelweni Disconnect power and clear debris Ensure pump is primed and has continuous water supply |
8. Imininingwane
| Isici | Ukucaciswa |
|---|---|
| Umkhiqizi | Steinbach |
| Inombolo Yemodeli | 040955 |
| Ubukhulu bomkhiqizo (L x W x H) | 22.5 x 15.5 x 33.5 cm (8.86 x 6.1 x 13.19 amayintshi) |
| Isisindo | 4 kg (8.82 lbs) |
| Isilinganiso sokugeleza | 6000 l/h (75 Liters per minute) |
| Max. Head Height | 6.5 amamitha |
| Voltage | 240 volts |
| Ukusetshenziswa kwamandla | 200 Watts |
| Okubalulekile | Ipulasitiki |
| Umbala | Mnyama, Isiliva |
| Hose Connection Diameter | 32mm / 38mm |
| Ubukhulu. Amanzi Okushisa | 35 ℃ |
| Isitifiketi | Okuqinisekisiwe ngaphandle kokukhungatheka |
| Ikhodi Yesihloko Yomhlaba Wonke | 9008748409551 |
9. Iwaranti kanye Nokusekela
Specific warranty information for the Steinbach 040955 CPS 40-2 Filtration Pump is not explicitly provided in the product data. For any product-related inquiries, technical support, or warranty claims, please contact Steinbach customer service directly or refer to the official Steinbach website for detailed support information.
Please retain your proof of purchase for any warranty-related matters.