Siemens BQD345 45-Amp Three Pole Circuit Breaker

Incwadi Yeziqondiso

1. Isingeniso

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Siemens BQD345 45-Amp Three Pole Circuit Breaker. Please read this manual thoroughly before attempting any installation or operation. Retain this manual for future reference.

2. Ulwazi Lokuphepha

ISEXWAYISO: Electrical shock hazard. Installation and servicing of this equipment must be performed by qualified personnel only. Always disconnect power at the main service panel before working with circuit breakers or electrical panels.

  • Qinisekisa ukuthi wonke amakhodi kagesi endawo nawezwe ayalandelwa ngesikhathi sokufakwa.
  • Do not install damaged equipment. Inspect the circuit breaker for any signs of damage before installation.
  • Never attempt to bypass or modify the circuit breaker's protective functions.
  • Siemens strongly recommends against the use of 'used' breakers. The installation of used breakers in a Siemens panel will void the warranty on the panel. Siemens does not sell used breakers and has not approved any 3rd party sellers to do so.

3. Umkhiqizo Uphelileview

The Siemens BQD345 is a 45-Amp, three-pole, bolt-in type circuit breaker designed for panel board mounting. It is rated for 480Y/277V AC with a 14KAIC interrupting rating. This thermal-magnetic circuit breaker provides overcurrent protection for electrical circuits.

Izici Eziyinhloko:

  • Type BQD
  • Three Pole Configuration
  • 45 Amps Current Rating
  • 480Y/277V AC Voltage Isilinganiso
  • 14KAIC Interrupting Rating
  • Ukukhwezwa Kwebhodi Lephaneli (Bolt-in)
  • Uhlu lwe-UL

Izithombe Zomkhiqizo:

Siemens BQD345 45-Amp Three Pole Circuit Breaker, main view
Umfanekiso 3.1: Okuyinhloko view of the Siemens BQD345 circuit breaker, showing its overall structure and terminals.
Siemens BQD345 45-Amp Three Pole Circuit Breaker, front view namalebula
Umfanekiso 3.2: Ngaphambili view of the BQD345 circuit breaker, highlighting the Siemens branding, specifications, and the ON/OFF/TRIP indicator.
Siemens BQD345 45-Amp Three Pole Circuit Breaker, side view
Umfanekiso 3.3: Side view of the BQD345 circuit breaker, showing the mounting points and general profile.
Siemens BQD345 45-Amp Three Pole Circuit Breaker, rear view namatheminali
Umfanekiso 3.4: Ngemuva view of the BQD345 circuit breaker, displaying the bolt-in terminals and product identification barcode (OM-1962015-1Q-2546).

4. Ukusetha nokufakwa

The Siemens BQD345 circuit breaker is designed for bolt-in installation within a compatible panel board. Installation must be performed by a qualified electrician in accordance with all applicable electrical codes.

  1. Ukunqanyulwa kwamandla: Before beginning any work, ensure that all power to the electrical panel is completely disconnected at the main service entrance. Verify with a voltagumhloli.
  2. Ukufinyelela Kwephaneli: Carefully remove the cover of the electrical panel to expose the bus bars and wiring area.
  3. Ukukhweza: Position the BQD345 circuit breaker onto the designated bus bar connections in the panel board. Securely fasten the breaker using the bolt-in mechanism.
  4. Izintambo: Connect the load wires to the appropriate terminals on the circuit breaker. Refer to the breaker's label for correct wire sizing (e.g., for 45A, Cu-Al 60°/75°C wire, size 8 AWG for 45A). Ensure all connections are tight and secure.
  5. Ukuhlanganiswa kabusha kwephaneli: Once wiring is complete and verified, replace the panel cover.
  6. Ukubuyisela Amandla: Restore power at the main service entrance.

For detailed wiring diagrams and specific panel compatibility, consult the panel board manufacturer's instructions and relevant electrical codes.

5. Iziqondiso Zokusebenza

The BQD345 circuit breaker features a toggle handle that indicates its current status:

  • ON: The handle is in the 'ON' position, indicating that power is flowing through the circuit.
  • VALIWE: The handle is in the 'OFF' position, indicating that power to the circuit is disconnected.
  • UHAMBO: If an overcurrent or short circuit condition occurs, the breaker will automatically move to the 'TRIP' position (typically a central position between ON and OFF). This indicates that the circuit has been interrupted for safety.

To reset a tripped breaker: First, move the handle completely to the 'OFF' position, then push it firmly to the 'ON' position. If the breaker immediately trips again, there is likely a persistent fault in the circuit that requires investigation by a qualified electrician.

6. Isondlo

Regular maintenance helps ensure the longevity and reliable operation of your circuit breaker. All maintenance should be performed by qualified personnel with power disconnected.

  • Ukuhlola Okubonakalayo: Periodically inspect the circuit breaker and its connections for any signs of overheating, discoloration, loose wires, or physical damage.
  • Ukuhlanza: Keep the area around the circuit breaker clean and free of dust and debris. Use a dry, non-conductive cloth for cleaning.
  • Ukuhlola: While not typically required for residential or light commercial applications, some industrial standards may require periodic testing of circuit breakers. Consult relevant standards and a qualified electrician for such requirements.

7. Ukuxazulula izinkinga

If your Siemens BQD345 circuit breaker is not functioning as expected, consider the following:

  • I-breaker Trips Ngokuvamile: This indicates an overcurrent condition or a short circuit in the protected circuit. Disconnect all loads from the circuit and try resetting the breaker. If it still trips, there is a fault in the wiring or a connected appliance. Consult a qualified electrician.
  • I-breaker Ngeke Isethwe Kabusha: Ensure the handle is pushed fully to the 'OFF' position before attempting to move it to 'ON'. If it still won't reset, or immediately trips, a fault is present.
  • Awekho Amandla Wokujikeleza (I-Breaker IVULIWE): Check the main service panel for tripped main breakers. Verify all connections to the BQD345 are secure. If the issue persists, professional electrical diagnosis is required.

Do not attempt to force a breaker into the ON position if it resists or immediately trips. This can indicate a serious electrical fault.

8. Imininingwane

IsibaluliInani
IbhrendiSIEMENS
Inombolo YemodeliI-BQD345
Isilinganiso samanje45 Amps
Inombolo Yezigxobo3
Voltage Isilinganiso480Y/277V AC
Ukuphazamisa Isilinganiso14 KAIC
Circuit Breaker UhloboThermal-Magnetic, Standard
Uhlobo LokukhwezaPanel Mount (Bolt-in)
Isisindo sento1.81 amakhilogremu
Ubukhulu bomkhiqizo4 x 3 x 3 amayintshi
I-UPC783643277403
Izingxenye EzihlanganisiweCircuit Breaker, 45A, Bolt On, 480V, 3P

9. Iwaranti kanye Nokusekela

Ulwazi Lwesiqinisekiso:

Siemens strongly recommends against the use of "used" breakers. The installation of used breakers in a Siemens panel will void the warranty on the panel. Siemens does not sell used breakers and has not approved any 3rd party sellers to do so. For specific warranty terms and conditions, please refer to the official Siemens warranty documentation or contact Siemens customer support.

Ukwesekwa Kwamakhasimende:

Ukuze uthole usizo lobuchwepheshe, imibuzo yomkhiqizo, noma izimangalo zewaranti, sicela uvakashele i-Siemens esemthethweni website or contact their customer service department. Ensure you have your product model number (BQD345) and any relevant purchase information available when contacting support.

Amadokhumenti Ahlobene - I-BQD345

Ngaphambiliview I-Siemens WL Circuit Breakers: Umhlahlandlela Wokukhetha kanye Nesicelo
Umhlahlandlela ophelele we-Siemens WL Low Voltage Ama-Circuit Breakers, ukukhethwa okumboza, uhlelo lokusebenza, izici, imininingwane, kanye nezinsiza ze-UL489 kanye ne-UL1066 yemikhiqizo esohlwini.
Ngaphambiliview Ama-Siemens WL Power Circuit Breakers: Umhlahlandlela Ophelele kanye Nemininingwane
Hlola uchungechunge lwe-Siemens WL lwama-power circuit breakers, izici ezinemininingwane, ukuhambisana ne-UL 489 kanye ne-UL 1066, amayunithi ohambo lwe-elekthronikhi (ama-ETU), izesekeli, kanye nezincazelo zobuchwepheshe zokusatshalaliswa kwamandla ezimbonini.
Ngaphambiliview Siemens Ivolumu Ephansitage I-Power Circuit Breaker UL 1066 Imiyalo Yokusebenza
Imiyalelo egcwele yokusebenza kwe-Siemens Low Voltage-Power Circuit Breakers, ikakhulukazi uchungechunge lwe-UL 1066. Lo mhlahlandlela uhlanganisa ukufakwa, ukugunyazwa, ukunakekelwa, kanye nemininingwane yobuchwepheshe yalawa ma-circuit breaker kanye nama-cradle ahlobene nawo.
Ngaphambiliview I-Siemens Power Protection Devices: MCB, RCCB, MCCB, ACB - Product Overview kanye Nemininingwane Yezobuchwepheshe
Okuphelele phezuview yamadivayisi e-Siemens SENTRON kanye ne-SINOVA yokuvikela isekethe, okuhlanganisa ama-Miniature Circuit Breakers (MCBs), Residual Current Circuit Breakers (RCCBs), Molded Case Circuit Breakers (MCCBs), kanye nama-Air Circuit Breakers (ACBs). Imininingwane yamaphothifoliyo omkhiqizo, ukucaciswa kobuchwepheshe, izinhlelo zokusebenza, nezici zokuphepha.
Ngaphambiliview I-Siemens Circuit Breaker eneyunithi yohambo lwe-Thermal-Magnetic - Imiyalelo yokusebenza
Imiyalo ebanzi yokusebenza yama-Siemens 3VA51 ama-circuit breaker, echaza izexwayiso zokuphepha, izinqubo zokufaka, izinketho zokuxhuma, kanye nokucaciswa kobuchwepheshe.
Ngaphambiliview Uhlelo lwe-Siemens Type TCP Circuit Breaker Maintenance Program namasevisi
Umhlahlandlela ophelele we-Siemens Uhlobo lwe-TCP SF6 yokugcinwa kwe-circuit breaker, okuhlanganisa izikhathi zokunakekela ezinkulu, insizakalo yasensimini, ukuqeqeshwa, izingxenye zokuvuselela, ukuthuthukiswa, namathiphu okuxazulula inkinga.