Altronix PD4

Altronix PD4 Power Distribution Module User Manual

Imodeli: PD4

1. Isingeniso

The Altronix PD4 is a power distribution module designed to efficiently manage power delivery. It converts a single AC or DC input into four (4) individually fuse-protected outputs. This module is suitable for various low-voltage applications requiring reliable power distribution and circuit protection.

2. Ulwazi Lokuphepha

Please read and understand all instructions before installing or operating the Altronix PD4. Failure to follow these instructions may result in injury or damage to the device.

3. Izici

4. Imininingwane

UkucaciswaInani
Okokufaka Voltage12-24VDC
Inani Lokukhiphayo Kwamanje10A (ubuningi)
Inombolo Yemiphumela4 (individually fused)
Ubukhulu bomkhiqizo3.4 x 1.75 x 5.9 amayintshi
Isisindo sento1 iphawundi
Inombolo YemodeliPD4
UmkhiqiziI-Altronix Corporation

5. Ukusetha nokufakwa

Before proceeding, ensure all power is disconnected from the input source.

5.1. Ukukhweza

The PD4 module can be mounted using screws through the designated mounting holes on the board. Choose a secure, dry location with adequate ventilation.

5.2. Izintambo zokuxhuma

  1. Amandla Okufaka: Connect the 12-24VDC power source to the input terminals labeled 'MAIN FUSE' or similar input terminals. Observe correct polarity (positive to positive, negative to negative).
  2. Amadivayisi Okukhiphayo: Connect your devices requiring power to the four (4) output terminal pairs (1P/1N, 2P/2N, 3P/3N, 4P/4N). Each output is individually protected by a fuse. Ensure the total current draw for all connected devices does not exceed 10A.
  3. Ukufakwa kwe-Fuse: Insert the appropriate fuses into the designated fuse holders for each output. Refer to the markings on the board for recommended fuse ratings.
Altronix PD4 Power Distribution Module board, top view

Figure 1: Altronix PD4 Power Distribution Module board, top view. Shows the main fuse holder, four sets of output terminals, and fuse locations for each output.

Altronix PD4 Power Distribution Module board, angled view

Figure 2: Altronix PD4 Power Distribution Module board, angled view. Highlights the terminal blocks for input and output connections, along with the fuse holders.

5.3. Phakamisa amandla

Once all connections are secure and fuses are in place, apply power to the input terminals. The power indicator LED (if present) on the board should illuminate, indicating proper power input.

6. Iziqondiso Zokusebenza

The Altronix PD4 operates automatically once power is supplied. It distributes the input power to the four connected output devices, with each output protected by its respective fuse. There are no user-adjustable settings or controls on the module itself beyond the initial wiring and fuse selection.

7. Isondlo

The Altronix PD4 requires minimal maintenance. Regular checks can help ensure continued reliable operation.

8. Ukuxazulula izinkinga

InkingaImbangela EngenzekaIsixazululo
No power to any output, power LED off.No input power, incorrect input voltage, main fuse blown.Check input power source. Verify input voltage. Replace main fuse if blown (ensure correct rating).
No power to a specific output, other outputs working.Blown fuse for that specific output, faulty wiring to the device.Identify and replace the blown output fuse. Check wiring to the affected device.
Ama-fuse aqhuma njalo.Overcurrent draw from connected device, short circuit in wiring or device.Reduce load on the output. Inspect wiring and connected device for short circuits. Ensure correct fuse rating.
Module feels excessively hot.Overload, insufficient ventilation, loose connections.Reduce total load. Ensure adequate airflow. Tighten all terminal connections.

9. Iwaranti kanye Nokusekela

For warranty information and technical support, please refer to the official Altronix website or contact Altronix customer service directly. Keep your purchase receipt for warranty claims.

I-Altronix Corporation
Webindawo: www.altronix.com
Contact information can typically be found on their webindawo.

Amadokhumenti Ahlobene - PD4

Ngaphambiliview I-Altronix ALTV1224DC Series CCTV Power Supplies Umhlahlandlela wokufaka
Comprehensive installation guide for Altronix ALTV1224DC Series CCTV Power Supplies. Details models, specifications, features, terminal identification, safety warnings, and enclosure dimensions for reliable CCTV power distribution.
Ngaphambiliview Altronix PD8/PD8CB Power Distribution Modules - Specifications and Installation Guide
Comprehensive guide for Altronix PD8 and PD8CB power distribution modules, detailing their overview, technical specifications, and step-by-step installation instructions for 8 fused or PTC protected outputs.
Ngaphambiliview Altronix ACMS12 Series Access Power Controllers Installation Guide
Installation guide for Altronix ACMS12 and ACMS12CB series sub-assembly access power controllers. Details specifications, wiring, and application diagrams for secure access control systems.
Ngaphambiliview I-Altronix ALTV244UL Series CCTV Power Supplies Umhlahlandlela wokufaka
Umhlahlandlela wokufaka we-Altronix ALTV244UL uchungechunge lwe-CCTV, amamodeli anemininingwane, imininingwane, imiyalelo yokufaka, kanye nobukhulu bendawo ebiyelwe. Ifaka okukhipha okungu-24VAC/28VAC okune-fuse noma ukuvikelwa kwe-PTC kwamakhamera e-CCTV nezesekeli zevidiyo.
Ngaphambiliview Altronix AL125ULB Two Output Switching Power Supply/Charger Datasheet
Ukucaciswa kobuchwepheshe nangaphezuluview for the Altronix AL125ULB, a two-output switching power supply and charger with PTC protected 12VDC/24VDC outputs, battery backup, and supervision features.
Ngaphambiliview I-Altronix R1224DC16CBV Rack Mount Power Supply Guide
Umhlahlandlela wokufaka we-Altronix R1224DC16CBV Rack Mount Power Supply, echaza imininingwane yayo, izici, kanye nezinqubo zokufaka isinyathelo ngesinyathelo zokufaka i-rack noma ishelufu. Inikeza okukhiphayo okungu-12VDC noma okungu-24VDC okunemiphumela evikelwe engu-16 ye-PTC.