Intermatic ET1105C

Intermatic ET1105C 24-Hour Electronic Time Switch Instruction Manual

Model: ET1105C

Isingeniso

This manual provides instructions for the installation, operation, and maintenance of the Intermatic ET1105C 24-Hour Electronic Time Switch. This device is designed to control electrical loads with precise, programmable timing, offering an upgrade from mechanical time switches with features like up-to-the-minute programming, battery backup, and automatic daylight saving time corrections.

Ulwazi Lokuphepha Olubalulekile

ISEXWAYISO: Ingozi Yomlilo noma Yokuthuthumela Kagesi

AVERTISSEMENT: Risque d'incendie ou de choc électrique

Pour les boîtiers en plastique, la liaison entre les raccordements de conduits n'est pas automatique et doit être prévue dans le cadre de l'installation.

Umkhiqizo Uphelileview

Intermatic ET1105C Electronic Time Switch with cover open, showing the control panel, LCD display, buttons, and wiring terminals.

Image: Intermatic ET1105C Electronic Time Switch with its protective cover open, revealing the digital display, control buttons (MODE, RESET, ENTER/NEXT, ON/OFF, +, -), and the wiring terminal block at the bottom. The internal wiring diagram and specifications are visible on the left panel.

The Intermatic ET1105C is an electronic 24-hour time switch designed for direct control of loads up to 30 amps resistive or inductive, and tungsten loads. It features battery-powered carryover for program retention during power outages.

Iphaneli yokulawula

Ukufakwa

Voltage Ukukhetha

The ET1105C supports multi-volt operation from 120 to 277 VAC, 50/60 Hz. Refer to the internal instruction manual or wiring diagram for specific voltage selection procedures.

Izintambo

Wiring should be performed by a qualified electrician in accordance with all local and national electrical codes.

  1. Ensure all power to the circuit is disconnected at the main breaker before beginning installation.
  2. Mount the time switch securely in the desired location.
  3. Connect the power supply wires to the designated terminals.
  4. Connect the load wires to the appropriate output terminals.
  5. Ensure all terminal screws are firmly tightened and no wire insulation is caught under the terminal plate.
  6. Replace the plastic insulator covering the terminals before restoring power.

Refer to the wiring diagram printed on the inside of the enclosure for detailed connection instructions.

Imiyalelo yokusebenza

Imanuwali ON/OFF Operation

In either AUTO or MANUAL mode, press the KHANYISA CISHA button to manually toggle the load. The display will indicate if the load is currently ON or OFF.

Izinyathelo Zokuhlela

The time switch allows for up to 28 events (14 ON / 14 OFF).

  1. Ukufinyelela kumamenyu: Cindezela inkinobho IMODE button repeatedly to cycle through the programming menus (DATE, TIME, ON/OFF EVENTS).
  2. Ukusetha Usuku: When "SET DATE" appears, use the + or - keys to enter the current date. Press NGENA ukuqinisekisa.
  3. Isikhathi Sokusetha: When "SET CLOCK" appears, use the + or - keys to enter the current time. Press NGENA ukuqinisekisa.
  4. Setting ON/OFF Events: When "ON/OFF EVENTS" appears, press the + or - button. The display will show "12:00 AM" with the load status (ON/@) and event number. Use the + or - keys to set the desired ON or OFF time and day(s) for the event. Press the KHANYISA CISHA load button to toggle the load status (ON or OFF). To clear an event, select "(nil)". Press NGENA to save the event and move to the next event, or press IMODE to advance to AUTO run mode.

Imodi ezenzakalelayo (AUTO)

Cindezela inkinobho IMODE button repeatedly until "AUTO" appears on the display. In AUTO mode, the time switch will execute the programmed ON/OFF events. Manual overrides using the KHANYISA CISHA load button are temporary and will revert to the programmed schedule at the next event.

Ukuhlela kanye no-ReviewImicimbi

Events can be edited or reviewed by returning to the appropriate menu using the IMODE inkinobho.

Isondlo

Ukushintshwa Kwebhethri

The time switch uses two industrial-grade AAA standard non-rechargeable 1.5-volt alkaline batteries for program retention.

  1. To replace the battery, locate the battery tray.
  2. Pull the battery tray out and downward to remove the battery holder.
  3. Shintsha amabhethri, uqaphela ukuhlukana okulungile.
  4. The batteries should be replaced approximately every 3 years after installation.

Imininingwane

IsiciUkucaciswa
ImodeliI-ET1105C
Timer Supply120-277 VAC, 60 Hz
Ukusetshenziswa Kwamandla Okukhulu6.0 W
Switch Rating (SPST)30 A Inductive/Resistive 120/240 VAC, 60 Hz
DC Resistive20 A Resistive 28 VDC
HP Rating (120 VAC)1 HP
HP Rating (240 VAC)2 HP
Umthwalo we-Tungsten5 A Tungsten 120/240 VAC, 60 Hz
Ballast Load20 A Ballast 120-277 VAC, 60 Hz
Inombolo YemicimbiUp to 28 (14 ON/14 OFF)
Uhlobo Lwebhethri2 x AAA Alkaline (ifakiwe)
Impilo YebhethriCishe iminyaka emi-3
Uhlobo Lwe-EnclosureType 1 Steel Enclosure
Ubukhulu3.25"D x 5.5"W x 8"H
Isisindo sento2.8 Amakhilogremu

Iwaranti

This product comes with a 1-year limited warranty. For detailed warranty information and claims, please contact Intermatic customer support.

Ukusekela

For technical assistance, troubleshooting, or further information, please visit the official Intermatic webisayithi noma uxhumane nomnyango wabo wesevisi yamakhasimende.

Intermatic Incorporated, Spring Grove, Illinois 60081-9698

Amadokhumenti Ahlobene - I-ET1105C

Ngaphambiliview Intermatic GMXFM1 Electronic Time Switch Instruction Manual
Instruction manual for the Intermatic GMXFM1 electronic time switch, covering safety precautions, symbols, initial setup, programming, time settings, daylight saving adjustments, operating modes, and warranty information.
Ngaphambiliview Intermatic ET1100 Series Electronic 24-Hour Time Switch Installation and User Instructions
Installation and user instructions for the Intermatic ET1100 Series Electronic 24-Hour Time Switch. Covers setup, programming, specifications, and warranty information for models ET1105C and ET1125C.
Ngaphambiliview Intermatic ET1100 Series Electronic Time Switches: Features, Specifications, and Models
Detailed information on the Intermatic ET1100 Series 24-Hour Electronic Time Switches, including features, technical specifications, contact ratings, enclosure options, and model variations for accurate load control.
Ngaphambiliview Intermatic T170, T1400 & T1800 Series Electromechanical Time Switches
Comprehensive details on Intermatic T170, T1400, and T1800 Series 24-Hour Electromechanical Time Switches, covering features, specifications, ratings, model variations, and wiring diagrams for commercial, industrial, and residential applications.
Ngaphambiliview Intermatic ET1100 Series Electronic 24-Hour Time Switch Installation and User Instructions
Comprehensive guide for installing and operating the Intermatic ET1100 Series Electronic 24-Hour Time Switch. Learn about specifications, wiring, programming, and maintenance for efficient load control.
Ngaphambiliview Intermatic Digi 42 Series Electronic Time Switch Operating Instructions
Operating instructions for the Intermatic Digi 42 Series electronic time switches, covering installation, programming, and troubleshooting for 24-hour and 7-day schedules.