Isingeniso
This manual provides detailed instructions for the installation, operation, and maintenance of your Hayward CL110 Off-line Automatic Chemical Feeder. This durable, corrosion-proof unit is designed to work automatically with your pool or spa pump and filter system, providing efficient and maintenance-free chemical dispensing. Please read this manual thoroughly before installation and use to ensure proper function and safety.

Image: The Hayward CL110 Off-line Automatic Chemical Feeder, a grey cylindrical unit with a black lid and a control dial on the side.
Ulwazi Lokuphepha
Always observe basic safety precautions when installing and operating this product. Failure to do so could result in serious injury or property damage.
- Funda yonke imiyalelo ngaphambi kokusebenzisa.
- Ensure the feeder is installed by a qualified professional in accordance with all local codes and ordinances.
- Always wear appropriate personal protective equipment (PPE) when handling pool chemicals.
- Never mix different types of chemicals in the feeder.
- Gcina endaweni lapho izingane zingafinyeleleki khona.
- Refer to the chemical manufacturer's instructions for safe handling and storage.
Ukusetha nokufaka
The Hayward CL110 is an off-line feeder, meaning it connects to your existing plumbing system. Simple installation is designed for do-it-yourselfers, but professional installation is recommended.
Izingxenye zifakiwe:
- CL110 Chemical Feeder Unit
- Ikhava
- Imanuwali (le dokhumenti)
- Connection Hoses and Fittings (may vary, refer to packaging)
Izinyathelo zokufaka:
- Khetha Indawo: Choose a location for the feeder that is easily accessible for refilling and maintenance, and is above the water level of the pool or spa.
- Izixhumanisi zamapayipi:
- Connect the inlet hose from the feeder to the pressure side of your pump and filter system (after the filter).
- Connect the outlet hose from the feeder to the return line of your pool or spa (before any heaters or other sensitive equipment).
- Qinisekisa ukuthi konke ukuxhumana kuvikelekile futhi akuvuzi.
- Ukukhweza: The unit is freestanding. Ensure it is placed on a stable, level surface.
- Ukugcwalisa kokuqala: Before adding chemicals, ensure the system is filled with water and all air is purged.
Qaphela: The input tube should be installed where the line from the pump goes into the filter head. The output should be on the return fitting at the pool.
Imiyalelo yokusebenza
The CL110 feeder uses 3-inch diameter Tricolor S tablets. The dial control valve allows you to adjust the chemical feed rate.
Adding Chemical Tablets:
- Vala Iphampu: Always turn off your pool/spa pump before opening the feeder.
- Vula Isembozo: The Easy-Lok threaded cover features a unique finger-release catch for safe and convenient access. Unscrew the cover counter-clockwise. Be aware that pressure may be present, so open slowly.
- Insert Tablets: Carefully place 3-inch diameter Tricolor S tablets into the feeder chamber. Do not overfill.
- Ikhava evikelekile: Replace the cover and tighten clockwise until snug. Do not overtighten, as the O-ring seal will create a seal under pressure.
- Restart Pump: Turn on your pool/spa pump.
Adjusting Feed Rate:
The dial control valve allows you to control and adjust the rate of feed. Monitor your pool's chlorine levels and adjust the dial accordingly.
- Vula ukudayela up (towards "FULL") to increase the chemical feed rate.
- Vula ukudayela phansi (towards "OFF") to decrease the chemical feed rate.
Regularly test your pool water to maintain desired chemical levels. Adjustments may be needed based on pool usage, weather, and other factors.
Isondlo
Regular maintenance ensures optimal performance and longevity of your chemical feeder.
- Ukuhlolwa kwe-O-Ring: Periodically inspect the O-ring on the cover for cracks or wear. Replace if necessary to prevent leaks. Lubricate with water-based gasket grease if opening becomes difficult.
- Ukuhlanza: If the feeder becomes clogged, especially the inlet valve, it may be due to unfiltered water debris. Disassemble the valve or use compressed air to clear blockages.
- Ukwenza ubusika: In colder climates, drain the feeder completely and store it in a dry, protected area during the off-season to prevent freeze damage.
Ukuxazulula inkinga
| Inkinga | Imbangela Engenzeka | Isixazululo |
|---|---|---|
| Feeder not dispensing chemicals |
|
|
| Water leaking from cover |
|
|
| Difficulty opening cover |
|
|
Imininingwane
- Ibhrendi: Hayward
- Inombolo Yemodeli: I-CL110
- Ubukhulu bomkhiqizo: 13.7"L x 6"W x 6.1"H
- Isisindo Sento: 4 amakhilogremu
- Umbala: Mnyama
- Okubalulekile: Insimbi, Ipulasitiki
- Amandla: 4.2 Pounds (for 3-inch diameter Tricolor S tablets)
- Uhlobo lokukhweza: I-Freestanding
- Isici esikhethekile: Ukumelana ne-UV
- I-UPC: 610377003728, 044927594518
Iwaranti kanye Nokusekela
Ukuze uthole ulwazi lwewaranti kanye nosekelo lobuchwepheshe, sicela ubheke i-Hayward esemthethweni website or contact Hayward customer service directly. Keep your purchase receipt for warranty claims.