I-AiM-logo

I-AiM LCU1S Isilawuli seLambda

AiM-LCU1S-Lambda-Controller-product

Ulwazi Lomkhiqizo

 Isingeniso

  • LCU1S is the new smaller, lighter and faster AiM Lambda Controller expansion supported by all the last car-bike AiM devices.
    Ngicela uqaphele: the only systems that does not support LCU1S are MXL, MXL2 and MyChron.
  • I-LCU1S ikuvumela ukuthi ushune kahle i-carburation yenjini kanye nokuthuthukisa ukusebenza kwenjini.
  • I-LCU1S isebenzisa i-Bosch LSU4.9 probe egcina ukulinganiswa kwangempela kwesikhathi sempilo yenzwa futhi ihlala ngaphezu kuka-100.000 km emotweni yesitoko.

Amakhithi atholakalayo, ongakhetha kukho kanye nezingxenye ezisele

Amakhithi e-LCU1S atholakalayo yilawa:

  • LCU1S complete kit; part number: X08LCU1SAC090
    • I-LCU1S
    • I-probe ye-Bosch LSU 4.9 Lambda
    • Indandatho yensimbi yokufakelwa ngentambo

LCU1S kit without Lambda probe; part number: X08LCU1SAC0

  • I-LCU1S

Optionals7 and spare parts:

  • Bosch LSU 4.9 Lambda probe X05LSU490
  • Thread iron ring for installation LBS552680
  • 50cm AiM CAN cable V02552690
  • 100cm AiM CAN cable V02552700
  • 200cm AiM CAN cable V02552720
  • 400cm AiM CAN cable V02551070

Configuring LCU1S

I-LCU1S ingalungiselelwa kuphela kusetshenziswa isofthiwe ye-AiM RaceStudio 3 ongayilanda mahhala ku-AiM webindawo ku www.aim-sportline.com landa indawo yesofthiwe/ye-firmware.
LCU1S is an expansion that is to be loaded on AiM device configuration so first of all run the software and select the configuration where to load LCUS1S on or create a new one as shown here below. To create a new configuration:

  • Press “New Configuration” (1)
  • Select the device you are configuring (Solo 2 DL v2 in the example below 2)
  • Cindezela okuthi “KULUNGILE” (3)

AiM-LCU1S-Lambda-Controller- (1)

Isofthiwe ingena kuthebhu ethi “Iziteshi”.

AiM-LCU1S-Lambda-Controller- (2)

To load LCU1S activate “CAN Expansions” (1) tab as shown here below and follow these steps:

  • Press “New Expansion” (2)
  • Select LCU1S (3)
  • Cindezela okuthi “KULUNGILE” (4)

AiM-LCU1S-Lambda-Controller- (3)

Once the expansion added, the software enters the related tab (0LC1S). Here it is possible to:

  • Get the serial number of LCU1S or fill it in manually (1); please note: to get the serial number from the connected LCU1S it is necessary to power it and connect the master device LCU1S is connected to your PC via Wi-Fi (or via USB). Please refer to the user manual of each logger to know how to manage Wi-Fi connection;
    • select the multiplier to calculate AFR from Lambda value
    • manage custom values through the dedicated panel that is prompted clicking the proper button
  • As far as the channel table (2) is concerned, clicking on each channel it is possible to set sampimvamisa ye-ling, Iyunithi yesilinganiso nokunemba kwesibonisi.

AiM-LCU1S-Lambda-Controller- (4)

How to get the serial number of a connected LCU1S

To get the serial number of the connected LCU1S ensure that LCU1S is powered and connect the master logger to the PC. To do so:

  • click the Wi-Fi icon top right of the software view (or plug the USB cable of the logger in the PC USB port)
  • Select the logger to connect via Wi-Fi and press “Connect”.
  • AiM-LCU1S-Lambda-Controller- (5) Once the logger connected press “Get Expansion Serial Number” as shown here below
  • A panel is prompted: select the connected expansion to configure and press “OK”AiM-LCU1S-Lambda-Controller- (6)
  • the software comes back to “CAN Expansions” tab and shows LCU1S Serial number.AiM-LCU1S-Lambda-Controller- (7)

Ku-inthanethi view kanye nokuvuselelwa kwe-firmware

Once LCU1S connected and identified it is suggested to complete, save and transmit the configuration to the logger. This procedure changes according to the logger that is being configured.
Manje kungenzeka ukungena ku-inthanethi view and check LCU1S values. To do so:

  • faka “Ukucushwa” view
  • Press the logger you are configuring as shown here below.

AiM-LCU1S-Lambda-Controller- (8)

Isoftware ingena ku-inthanethi view:

  • Activate “Firmware” tab
  • I view ikhombisa i-logger kanye nokwandiswa kwayo ngakwesokudla kwe- view njengoba kuboniswe ngezansi.

AiM-LCU1S-Lambda-Controller- (11)

To update both logger and expansions firmware:

  • click the related button top right of the view
  • AiM-LCU1S-Lambda-Controller- (12)the software enters firmware update view where it is possible to download and install the firmware as for any AiM device.

AiM-LCU1S-Lambda-Controller- (13)

Ukucaciswa kobuchwepheshe nemidwebo

LCU1S technical specifications are

  • Sensor compatibility Bosch LSU4.
  • Amandla kagesi voltage9-15V
  • Power supply current 50mA ÷ sensor heater typical current 750 mA up to 2A on cold sensor
  • Reaction time Less than 10msec
  • Material Latigloss 57
  • Ubukhulu 43.4x30x18.4 mm
  • Isisindo 70g
  • I-IP67 engangeni manzi

LCU1S Dimensions in mm [inches]

AiM-LCU1S-Lambda-Controller- (9)

LCU1S Pinout

AiM-LCU1S-Lambda-Controller- (10)

imibuzo ejwayelekile ukubuzwa

Which AiM devices are not compatible with LCU1S?

MXL, MXL2, and MyChron are the systems that do not support LCU1S.

What is the lifespan of the Bosch LSU4.9 probe?

The probe lasts for more than 100,000 km on a stock car.

Amadokhumenti / Izinsiza

I-AiM LCU1S Isilawuli seLambda [pdf] Umhlahlandlela Womsebenzisi
X08LCU1SAC090, X08LCU1SAC0, X05LSU490, LCU1S Lambda Controller, LCU1S, Lambda Controller, Controller

Izithenjwa

Shiya amazwana

Ikheli lakho le-imeyili ngeke lishicilelwe. Izinkambu ezidingekayo zimakiwe *