I-AEMC INSTRUMENTS MN09 AC Uphenyo Lwamanje

DESCRIPTION
I-AEMC® Instruments Model MN09 (Cat. #2129.21) ingeyakamuva kuma-compact AC Current probes. Idizayinelwe ukuhlangabezana nezidingo eziqinile embonini nasezinkontilekeni zikagesi, iphinde ihlangabezane nezindinganiso zakamuva zokuphepha nokusebenza. I-probe inebanga lokulinganisa elifika ku-150 ARMS okuyenza ibe ithuluzi eliphelele lokulinganisa ngama-DMM namarekhodi ngaphandle kwebanga le-AC. I-Model MN09 ihambisana nanoma iyiphi i-voltmeter ye-DC, i-multimeter, noma enye ivolumutagithuluzi lokulinganisa elikwazi ukubonisa u-100 mV wokuphuma ngakunye amp yamanje elinganiselwe, ukunemba kwe-voltmeter okungu-0.75 % noma okungcono kanye nokuvinjelwa kokufaka okungu-≥ 50 kΩ.
ISEXWAYISO
Izixwayiso zokuphepha zinikezwa ukuze kuqinisekiswe ukuphepha kwabasebenzi kanye nokusebenza ngendlela efanele kwethuluzi. Funda imiyalelo ngokuphelele.
- Qaphela kunoma iyiphi isekethe: ivolumu enamandla amakhulutagama-e kanye nemisinga kungase kube khona futhi kungase kubangele ingozi yokushaqeka.
- Ungayisebenzisi i-probe uma yonakele. Njalo xhuma i-probe yamanje kudivayisi yokulinganisa ngaphambi kokuthi ixhunywe eduze kwekhondakta.
- Ungasebenzisi ku-conductor engagqunyiwe enamandla okuwisa ngaphezu kuka-600 V CAT III ukungcola 2. Sebenzisa ukuqapha okukhulu uma uqoqaampukuzungeza ama-conductor angenalutho noma amabhasi.
- Ngaphambi kokusetshenziswa ngakunye, hlola i-probe; bheka imifantu endlini noma ikhebula lokuphumayo.
- Ungasebenzisi i-clamp endaweni emanzi noma ezindaweni lapho kukhona amagesi ayingozi.
- Ungasebenzisi i-probe noma kuphi ngale kwesithiyo esithintekayo.
IZIMPAWU NENCAZELO YESILINGANISO
IZIMPAWU ZAMAZWE KAgesi
| Kubonisa ukuthi ithuluzi livikelwe ngokufakwa okuphindwe kabili noma okuqinisiwe. | |
| |
ISEXWAYISO - Ingozi Yengozi! Ikhombisa ISEXWAYISO. Noma nini lapho lolu phawu lukhona, opharetha kufanele abhekisele kumanuwali yomsebenzisi ngaphambi kokusebenza. |
| |
Isicelo noma ukuhoxiswa okugunyazwe kumakhondaktha aphethe umthamo oyingozitages. Thayipha inzwa yamanje njenge-IEC 61010-2-032. |
INCAZELO YEMIKHAKHA YOKUKALA (ICAT)
- I-CAT IV: Ihambisana nezilinganiso ezenziwa endaweni yokuqala kagesi (< 1000 V).
- Example: amadivayisi ayisisekelo okuvikela i-overcurrent, amayunithi okulawula ama-ripple, namamitha.
- I-CAT III: Ihambisana nezilinganiso ezenziwe ekufakweni kwesakhiwo ezingeni lokusabalalisa.
- Example: imishini eqinile ekufakweni okungaguquki kanye nama-circuit breaker.
- I-CAT II: Ihambisana nezilinganiso ezenziwa kumasekhethi axhunywe ngokuqondile ohlelweni lokusabalalisa ugesi.
- Example: izilinganiso zezinto zasendlini namathuluzi aphathekayo.
UKWAMUKELA UKUTHUNYELWA KWAKHO
- Lapho uthola ukuthunyelwa kwakho, qiniseka ukuthi okuqukethwe kuyahambisana nohlu lokupakisha.
- Yazisa umsabalalisi wakho nganoma yiziphi izinto ezingekho.
- Uma impahla ibonakala ilimele, file isimangalo ngokushesha nesithwali futhi wazise umsabalalisi wakho ngesikhathi esisodwa, unikeze incazelo enemininingwane yanoma yimuphi umonakalo.
I-AC CURRENT PROBE
I-AC CURRENT PROBE – MN09 DRAWING

IMICIMBI
IMINININGWANE KAgesi
- Ibanga Lebizo: 150 A
- Ibanga Lokulinganisa: (1 kuya ku-150) A~
- Isiginali Yokuphumayo: 100 mV = 1 AAC
- Ukunemba: (1 kuya ku-5) A: 10 % ± 0.2 A
- (5 kuya ku-15) A: 6 % ± 0.2 A
- (15 kuya ku-40) A: 3 % ± 0.2 A
- (40 kuya ku-150) A: 4 %
- Isigaba Shift: Akufaneleki
(*Izimo zereferensi: (20 kuye ku-26) °C, (20 kuya ku-75) % RH, inkambu kazibuthe yangaphandle engu-<40 A/m, (48 kuya ku-65) Hz sine wave, isici sokuhlanekezela ngaphansi kuka-1%, ayikho ingxenye ye-DC, akukho umqhubi ophethe wangaphandle wamanje, ukuhlolwa sample imaphakathi.) Layisha okuthize > 50 kΩ - Ukulayisha ngokweqile: 170 A imizuzu eyi-10
- Ibanga Lemvamisa: (48 kuya ku-500) Hz
- Vula Ivolumu Yesibilitage: ≤30 V
- Beka Umkhawulo Wezimo Zokusebenza: 150 A unomphela ukuya ku-500 Hz
- Umthelela we-Adjacent Conductor: < 2 mA/A ku-50 Hz
- Umthelela Wesikhundla Somqhubi Emhlathini: < 0.1 % wokukhishwa kwe-mV ku-50/60 Hz
- Umthelela Wemvamisa: (65 kuya ku-500) Hz: < ± 3 % wokukhiphayo kwe-mV
- Umthelela Wezinga Lokushisa: ≤ 200 ppm/°K, noma u-0.2 % wokukhipha i-mV ngo-10 °K ngamunye
- Umthelela Womswakama: (10 kuya ku-90) % RH, ≤ 0.1 % wokukhiphayo kwe-mV
IMINININGWANE YOMKHETHI
- Izinga Lokushisa Lokusebenza:
- (14 kuya ku-122) °F (-10 kuya +50) °C
- Izinga Lokushisa Lesitoreji:
- (-40 kuya ku-176) °F (-40 kuya +80) °C
- Ukuswakama Okuhlobene Okusebenzayo: (14 kuya ku-122) °F
- 85 % RH (ngaphandle kokukhishwa ngaphezu kuka-122 °F)
- Ubukhulu Bekhebula Ububanzi: Okukodwa Ø 0.39 in (10 mm)
- Ukuvikelwa Kwecala: IP 40 (IEC 529)
- Ubukhulu: (4.43 x 1.48 x 1.02) ku
- (112.5 x 37.5 x 26) mm
- Isisindo: 180 g (6.5 oz)
- Okukhiphayo: Okufakwe kabili/okuqiniswe okuvamise ukuholela okungu-5 ft (1.5 m) ngokuphepha kukabhanana okungu-4 mm
IZINCACISO ZOKUPHEPHA
![]()
- Izinga lamazwe ngamazwe:
- Ukuphepha: EN 61010-2-032
- 600 V CAT III
- Ukuphepha: EN 61010-2-032
- Ukuvumelana kwe-Electromagnetic: I-EN 61326-1 ukungavikeleki kwezimboni
UKU-ODA ULWAZI
- I-AC Current Probe MN09…….. Ikati. #2129.21
Izinsiza:
- I-adaptha – Isethi yokubili, enombala onemibala
- (obomvu/omnyama) Owesifazane – Owesifazane Kuya Kwabesilisa Ukuhola………………………. Ikati. #2115.98
- I-adaptha – Ubhanana (Owesifazane) – BNC (Owesilisa)
- (XM-BB)………………………………. Ikati. #2118.46
UKUSEBENZA
Sicela wenze isiqiniseko sokuthi usuvele usifundile futhi usiqonda ngokugcwele isigaba SISEXWAYISO.
Ukwenza Izilinganiso nge-AC Current Probe Model MN01
- Xhuma intambo emnyama yophenyo lwamanje kokujwayelekile kanye nomthofu obomvu ku-DC voltage okokufaka ku-DMM yakho noma enye ivolumutaginsimbi yokulinganisa. Uphenyo lwamanje lwe-AC lunomphumela ongu-100 mVDC/AAC. Lokhu kusho ukuthi ku-150 AAC ku-conductor lapho uphenyo luyi-clamped, i-15 VDC izophuma ku-probe iholela ku-DMM noma insimbi yakho.
- Khetha ububanzi obuhambisana nomthamo wamanje olinganisiwe. Uma ubukhulu bamanje bungaziwa, qala ngebanga eliphakeme kakhulu futhi wehle kuze kube yilapho kufinyelelwa ububanzi obufanele nokulungiswa. Clamp i-probe ezungeze umqhubi. Thatha ukufundwa kumitha ukuphindaphinde ngo-10 ukuze uthole umthamo wamanje okaliwe (isb, 1000 mVDC Reading = 1000 x 10 = 10,000 mAAC noma 10 AAC).
- Ukuze uthole ukunemba okungcono kakhulu, gwema uma kungenzeka, ukusondela kwamanye amakhondatha angase adale umsindo.
Amathiphu Okwenza Izilinganiso Ezinembile
- Uma usebenzisa i-probe yamanje enemitha, kubalulekile ukukhetha ububanzi obunikeza ukulungiswa okungcono kakhulu. Ukwehluleka ukwenza lokhu kungase kubangele amaphutha okulinganisa.
- Qinisekisa ukuthi izindawo zokukhwelana kwe-probe azinalo uthuli nokungcoliswa. Ukungcola kubangela izikhala zomoya phakathi kwemihlathi, okwandisa ukuguquguquka kwesigaba phakathi kweprimary and secondary. Kubaluleke kakhulu ekulinganisweni kwamandla.
AMANDENI
Isexwayiso
- Ukuze ulondoloze sebenzisa izingxenye zokuqala ezishintshayo zasembonini kuphela.
- Ukuze ugweme ukushaqeka kukagesi, ungazami ukwenza noma iyiphi isevisi ngaphandle uma ufanelekile ukwenza kanjalo.
- Ukuze ugweme ukushaqeka kukagesi kanye/noma ukulimala kwethuluzi, ungavumeli amanzi noma amanye ama-agent angaphandle ukuthi athintane nophenyo.
Ukuhlanza
- Ukuqinisekisa ukusebenza kahle, kubalulekile ukugcina izindawo zokukhwelana zemihlathi zihlanzekile ngaso sonke isikhathi. Ukwehluleka ukwenza kanjalo kungase kubangele iphutha ekufundeni.
- Ukuze uhlanze imihlathi ye-probe, sebenzisa i-sand paper ecolekile kakhulu (fine 600) ukugwema ukunwaya umhlathi, bese uhlanza ngobumnene ngendwangu ethambile, enamafutha.
UKULUNGISA NOKULINGANISA
Ukuqinisekisa ukuthi ithuluzi lakho liyahlangabezana nokucaciswa kwefekthri, sincoma ukuthi libuyiselwe esikhungweni sethu sesevisi yefekthri ngezikhathi zonyaka owodwa ukuze lilungiswe kabusha noma njengoba kudingwa ngamanye amazinga noma izinqubo zangaphakathi.
Okokulungisa nokulinganisa izinsimbi:
Kufanele uxhumane neSikhungo sethu Sesevisi ukuze uthole Inombolo Yokugunyazwa Kwesevisi Yekhasimende (CSA#). Thumela i-imeyili ku repair@aemc.com ucela i-CSA#, uzonikezwa Ifomu le-CSA namanye amaphepha adingekayo kanye nezinyathelo ezilandelayo zokuqedela isicelo. Bese ubuyisela ithuluzi kanye nefomu le-CSA elisayiniwe. Sicela ubhale i-CSA# ngaphandle kwesiqukathi sokuthumela. Uma ithuluzi libuyiselwa ukuze lilinganiswe, sidinga ukwazi uma ufuna ukulinganisa okujwayelekile noma ukulinganisa okulandelekayo ku-NIST (kuhlanganisa nesitifiketi sokulinganisa kanye nedatha yokulinganisa erekhodiwe).
- Chauvin Arnoux®, Inc. dba AEMC® Izinsimbi
- 15 Faraday Drive ▪ Dover, NH 03820 USA
- Ucingo: 800-945-2362 (Ext. 360)
- 603-749-6434 (Ext. 360)
- Ifeksi: 603-742-2346
- I-imeyili: repair@aemc.com
(Noma xhumana nomsabalalisi wakho ogunyaziwe)
QAPHELA: Wonke amakhasimende kufanele athole i-CSA# ngaphambi kokubuyisela noma iyiphi insimbi.
USIZO LWEZOBUCHWEPHESHE NOKUDAYISA
Uma uhlangabezana nanoma yiziphi izinkinga zobuchwepheshe, noma udinga noma yiluphi usizo ngokusetshenziswa okufanele noma ukusetshenziswa kwaleli thuluzi, sicela uthinte inombolo yethu yocingo yobuchwepheshe:
- Chauvin Arnoux®, Inc. dba AEMC® Izinsimbi
- 15 Faraday Drive ▪ Dover, NH 03820 USA
- Ucingo: 800-343-1391 (Ext. 351)
- Ifeksi: 603-742-2346
- I-imeyili: techsupport@aemc.com
FAQ
imibuzo ejwayelekile ukubuzwa
- Q: Yini okufanele ngiyenze uma ngibona noma yimuphi umonakalo ku-AC Current Probe MN09?
- A: Ungayisebenzisi i-probe uma yonakele. Xhumana nomsabalalisi wakho ukuze uthole usizo kanye nezinketho ezingase zilungiswe noma zokushintshwa.
- Q: Ingabe i-AC Current Probe MN09 ingasetshenziswa kumakhondaktha angewona ama-insulated?
- A: Akunconywa ukusebenzisa i-probe kumakhondaktha angafakwanga ngci enamandla okuwisa ngaphezu kuka-600 V ngezizathu zokuphepha.
ISIQINISEKISO SOMKHAWULO
Uphenyo lwamanje luqinisekiswa kumnikazi isikhathi esiyiminyaka emibili kusukela ngosuku lokuthenga kwasekuqaleni uma kuqhathaniswa nokukhubazeka ekwenziweni. Lesi siqinisekiso esikhawulelwe sinikezwa i-AEMC® Instruments, hhayi umsabalalisi ethengwe kuye. Lesi siqinisekiso asinalutho uma iyunithi ibiyi-tampihlukunyeziwe, noma uma isici sihlobene nesevisi engenziwanga i-AEMC® Instruments.
Ukufakwa kwewaranti ephelele nokubhaliswa komkhiqizo kuyatholakala kithi webisayithi ku: www.aemc.com/warranty.html.
Sicela uphrinte Ulwazi Lwewaranti eku-inthanethi lwamarekhodi akho.
Amadokhumenti / Izinsiza
![]() |
I-AEMC INSTRUMENTS MN09 AC Uphenyo Lwamanje [pdf] Imaniwali yosebenzisayo I-MN09 AC Current Probe, MN09, AC Current Probe, Current Probe, Probe |