Isingeniso
The SINOTIMER TM630A is a compact, programmable digital timer switch designed to automatically control various electrical equipment by switching them on and off at preset times. This device is suitable for a wide range of applications, including controlling streetlights, neon signs, lamps, water heaters, air conditioners, billboards, electric cookers, boosters, sprayers, bottlers, preheaters, agriculture facilities, and broadcasting equipment. It features a built-in battery to retain programmed settings during power failures, ensuring reliable operation. The TM630A is built with a high-accuracy CMOS chip, offers strong anti-jamming capabilities, and is simple to set up and operate. It conforms to IEC 60367 standards and is CE certified.
Imininingwane
| Isici | Ukucaciswa |
|---|---|
| Imodeli | TM630A (also TM630A-4) |
| Uhlobo | Mini Digital Timer Switch |
| I gama le-brand | SINOTIMER |
| Sebenzisa | Isikhathi Sokushintsha |
| Ukunikezwa kwamandla kagesi | 12V DC/AC |
| Okukhiphayo | 12V ivolumutage okukhiphayo |
| Ukusetshenziswa kwamandla | 3.5 VA (MAX) / 4.5 VA (MAX) |
| Bonisa | I-LCD |
| Switching Contact | 1 changeover switch (1NO) |
| Amandla | 30A 250V AC (5000 Watt / 30 Amps) |
| Izinhlelo | 16 ON/OFF settings per day or week |
| Programming Combinations | 15 Amaqembu |
| Mini Interval | 1 iminithi |
| Ibanga lesibali sikhathi | 1 iminithi ukuya emahoreni ayi-168 |
| Izinga Lokushisa | -20°C kuya +50°C |
| I-Hysteresis | 2 sec/day (at 25°C) |
| Average Error | 1 sec/24h (at 25°C) |
| Auto Time Error Correction | +/- 30 sec, weekly |
| Ukufakwa | DIN RAIL or Screw mounted |
| Ubukhulu | 98 x 55 x 40 mm |
| Isisindo | 0.15 kg |
| Inside Battery | 1.2V (rechargeable, for memory backup) |
| Black-out Memory Retention | 60 izinsuku |
| Izitifiketi | CE, RoHS, EMC, LVD |
Setha
1. Ukufakwa
The TM630A timer switch can be installed either on a DIN rail or screw-mounted. Ensure the installation location is dry, well-ventilated, and within the specified temperature range (-20°C to +50°C).
2. Umdwebo Wiring
Refer to the following wiring diagram for proper connection. Ensure all connections are secure and comply with local electrical codes. This diagram shows the connections for the 12V DC/AC input and the load output.

The timer has two input terminals for power (typically marked L and N for AC, or + and - for DC) and two output terminals for the load.
3. Ukuvuselelwa Kokuqala
Upon initial power-up or after extended storage, the internal 1.2V rechargeable battery may be low. Connect the timer to its power supply (12V DC/AC) for a few hours to allow the internal battery to charge. This battery maintains the programmed settings during power outages.
Imiyalelo yokusebenza
1. Imisebenzi Yenkinobho
Familiarize yourself with the buttons on the front panel:

- C/R (Khansela/Khumbula): Clears current settings or recalls saved programs.
- D+ (Usuku): Adjusts the day of the week.
- Ihora+ (Ihora): Adjusts the hour.
- M+ (Umzuzu): Adjusts the minute.
- P (Program/Timer): Enters programming mode.
- IWASHI: Used in combination with D+, H+, M+ to set the current time and day.
- INCWADI: Manually switches the output ON/OFF or sets to AUTO mode.
2. Setting the Present Time and Day
To set the current time and day of the week:
- Cindezela bese ubamba i IWASHI inkinobho.
- Esabambe IWASHI, cindezela IHORA ukusetha ihora lamanje.
- Esabambe IWASHI, cindezela MINUTE ukusetha umzuzu wamanje.
- Esabambe IWASHI, cindezela USUKU ukusetha usuku lwamanje lweviki.
3. Izikhathi Zokuvula/Ukuvala Izinhlelo
The timer supports up to 16 ON/OFF programs per day or week. Follow these steps to set your desired schedules:

- Cindezela inkinobho TIMER (P) button once to enter the 1st ON time setting. The display will show "1 ON".
- Cindezela IHORA, MINUTE, futhi USUKU buttons to set the desired time and day(s) for the 1st ON event.
- USUKU button allows selecting various combinations of days (e.g., MO, TU, WE, TH, FR, SA, SU; MO, TU, WE, TH, FR; SA, SU; MO, WE, FR; TU, TH, SA; MO, TU, WE; TH, FR, SA; MO, WE, FR, SA; MO, TU, WE, TH, FR, SA, SU).
- Cindezela inkinobho TIMER (P) button again. The display will show "1 OFF".
- Cindezela IHORA, MINUTE, futhi USUKU buttons to set the desired time and day(s) for the 1st OFF event.
- Repeat steps 1-4 for additional ON/OFF programs (up to 16 pairs).
- Ukuphuma kumodi yokuhlela, cindezela inkinobho IWASHI inkinobho.
4. Ukukhipha Mathupha
I INCWADI button allows you to override the programmed settings temporarily or permanently:
- Cindezela INCWADI repeatedly to cycle through modes: ON (always on), OFF (always off), and AUTO (follows programmed schedule).
- In AUTO mode, the timer will execute the programmed ON/OFF events.
Isondlo
1. Ibhethri yangaphakathi
The TM630A includes a 1.2V rechargeable internal battery. This battery automatically recharges when the timer is connected to its power supply. It is designed to retain your programmed settings for up to 60 days during power outages. If the timer has been stored for a long period without power, allow it to charge for several hours before programming to ensure full memory retention.
2. Ukuhlanza
To clean the timer, gently wipe the exterior with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water.
Ukuxazulula inkinga
- Isibonisi asinalutho: Check if the timer is receiving power (12V DC/AC). If it has been without power for an extended period, the internal battery may be fully discharged. Connect to power and allow it to charge.
- Programs are not executing:
- Qinisekisa ukuthi isibali sikhathi sikhona NGOKUZENZAKALELAYO mode (check the display for "AUTO"). Press the INCWADI button to cycle to AUTO mode if necessary.
- Verify that the current time and day are set correctly.
- Check that the ON/OFF programs are correctly entered and enabled.
- Time drift: The timer has an auto time error correction of +/- 30 seconds weekly. Significant deviations may indicate an issue with the power supply or internal components.
- Loss of programs after power outage: While the internal battery provides memory retention for up to 60 days, prolonged power outages or a depleted internal battery can lead to program loss. Ensure the internal battery is adequately charged.
Amathiphu omsebenzisi
- For critical applications, consider testing your programmed schedules after initial setup to ensure they function as expected.
- Thatha i-advantage of the 15 programming group combinations to create complex weekly schedules for different days or sets of days.
- The manual override function is useful for temporary changes without altering your saved programs.
- Given its wide application range, this timer is highly versatile. Consider using it for automating garden irrigation, aquarium lighting, or even charging cycles for low-voltagamadivaysi e.
Iwaranti kanye Nokusekela
The SINOTIMER TM630A timer switch is certified with CE, RoHS, EMC, and LVD standards, indicating compliance with relevant health, safety, and environmental protection directives.
For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. The product package includes a manual in Russian, Portuguese, and English languages for detailed guidance.