I-ACCU-SCOPE - ilogoINCWADII-ACCU-SCOPE 3000-LED Amandla Aphakeme We-Microscope3000-LED
IMICROSCOPE SERIES

73 Mall Drive, Commack, NY 11725 • 631-864-1000 (P) • 631-543-8900 (F)
www.accu-scope.cominfo@accu-scope.com

AMAZWI OKUPHEPHA

  1. Vula ibhokisi lokuthumela ngokucophelela ukuze uvimbele noma yiziphi izinto ezisetshenziswayo, okungukuthi izinjongo noma iziqeshana zamehlo, ukuthi zingawi futhi zilimale.
  2. Ungalahli isitsha se-foam esibunjiwe; isiqukathi kufanele sigcinwe uma isibonakhulu sidinga ukuthunyelwa kabusha.
  3. Gcina ithuluzi lingangeni elangeni eliqondile, izinga lokushisa eliphezulu noma umswakama, kanye nezindawo ezinothuli. Qinisekisa ukuthi i-microscope isendaweni ebushelelezi, ileveli futhi eqinile.
  4. Uma noma yiziphi izixazululo zesifanekiso noma olunye uketshezi luchaphazela ku-stage, inhloso nanoma iyiphi enye ingxenye, nqamula intambo kagesi ngokushesha futhi usule ukuchitheka. Uma kungenjalo, ithuluzi lingalimala.
  5. Zonke izixhumi zikagesi (intambo yamandla) kufanele zifakwe kumshini wokucindezela ugesi ukuze kuvinjelwe umonakalo ngenxa yevolthi.tage ukushintshashintsha.
  6. Ukuze uvikeleke lapho ushintsha isibani se-LED noma i-fuse, qiniseka ukuthi iswishi enkulu ivaliwe (“O”), khipha intambo kagesi, bese ushintsha isibani se-LED ngemva kwesibani kanye ne-l.amp indlu isipholile ngokuphelele.
  7. Qinisekisa ukuthi ivolumu yokufakatagu-e okhonjiswe kusibonakhulu sakho uhambisana nevolumu yomugqa wakhotage. Ukusetshenziswa kwevolumu ehlukile yokufakatagngaphandle kwalokho okubonisiwe kuzodala umonakalo omkhulu kusibonakhulu.

UKUNAKEKELA KANYE NONDLO

  1. Ungazami ukuqaqa noma iyiphi ingxenye ehlanganisa iziqeshana zamehlo, izinjongo noma ukuhlanganisa okugxilile.
  2. Gcina ithuluzi lihlanzekile; khipha ukungcola kanye nemfucumfucu njalo. Ukungcola okunqwabelene ezindaweni zensimbi kufanele kuhlanzwe ngesikhangisoamp indwangu. Ukungcola okuphikelelayo kufanele kususwe kusetshenziswa isisombululo sensipho esithambile. Ungasebenzisi ama-solvents e-organic ukuhlanza.
  3. Indawo engaphandle ye-optics kufanele ihlolwe futhi ihlanzwe ngezikhathi ezithile kusetshenziswa ukusakazwa komoya okuvela kusibani somoya. Uma ukungcola kusala endaweni ekhanyayo, sebenzisa indwangu ethambile noma i-swab kakotini dampefakwe ngesisombululo sokuhlanza ilensi (etholakala ezitolo zamakhamera). Wonke ama-lens optical kufanele aswayishwe kusetshenziswa ukunyakaza okuyindilinga. Inani elincane lenxeba likakotini elimunca ekugcineni kwenduku ecijile njengama-swabs kakotini noma amathiphu e-Q, lenza ithuluzi eliwusizo lokuhlanza izindawo ezikhanyayo ezihlehlisiwe. Gwema ukusebenzisa isamba esiningi sezinyibilikisi njengoba lokhu kungase kubangele izinkinga ngezingubo zokukhanya noma izinto zokubona ezinosimende noma isincibilikisi esigelezayo singacosha amafutha okwenza ukuhlanza kube nzima kakhulu. Izinhloso zokucwiliswa kwamafutha kufanele zihlanzwe ngokushesha ngemva kokusetshenziswa ngokukhipha amafutha ngezicubu ze-lens noma indwangu ehlanzekile, ethambile.
  4. Gcina ithuluzi endaweni epholile, neyomile. Vala isibonakhulu ngekhava yothuli uma ingasetshenziswa.
  5. Amamicroscopes e-ACCU-SCOPE® angamathuluzi anembayo adinga ukunakekelwa okuvimbela ngezikhathi ezithile ukuze kugcinwe ukusebenza okufanele kanye nokunxephezela ukuguga okuvamile. Ishejuli yaminyaka yonke yokugcinwa kokuvikela okwenziwa ngabasebenzi abaqeqeshiwe inconywa kakhulu. Umsabalalisi wakho ogunyaziwe we-ACCU-SCOPE® angahlela le sevisi.

ISINGENISO

Siyakuhalalisela ngokuthenga isibonakhulu sakho esisha se-ACCU-SCOPE®. Izibonakhulu ze-ACCU-SCOPE® zakhiwe futhi zenziwa ngezinga eliphezulu lekhwalithi. Isibonakhulu sakho sizohlala impilo yonke uma sisetshenziswa futhi sinakekelwa kahle. Izibonakhulu ze-ACCU-SCOPE® zihlanganiswa ngokucophelela, zihlolwe futhi zihlolwe ngabasebenzi bethu bochwepheshe abaqeqeshiwe esikhungweni sethu saseNew York. Izinqubo zokulawula ikhwalithi ngokucophelela ziqinisekisa ukuthi isibonakhulu ngasinye sisezingeni eliphezulu kakhulu ngaphambi kokuthunyelwa.

UKUKHIPHA KANYE NEZINTO
Isibonakhulu sakho sifike sipakishwe esitsheni segwebu se-EPE esibunjiwe. Ungasilahli isiqukathi: isitsha segwebu le-EPE kufanele sigcinwe ukuze sithunyelwe kabusha ngesibonakhulu sakho uma sidingeka. Gwema ukubeka isibonakhulu endaweni enothuli noma ezindaweni ezishisayo noma ezinomswakama njengoba kuzokwakheka isikhunta nesikhutha.
Khipha ngokucophelela isibonakhulu esitsheni ngengalo nesisekelo bese ubeka isibonakhulu endaweni eyisicaba, engadlidlizi.

I-COMPONENT DIAGRAM

I-ACCU-SCOPE EXC-500 Isibonakhulu - IzingxenyeI-ACCU-SCOPE EXC-500 Isibonakhulu - IZIQINISEKISOI-ACCU-SCOPE EXC-500 Microscope - IZIQINISEKISO 2

UMDLALO WOMHLANGANO

Umdwebo ongezansi ubonisa indlela yokuhlanganisa amamojula ahlukahlukene. Izinombolo zikhombisa ukuhleleka komhlangano. Isibonakhulu sakho sahlanganiswa ochwepheshe befekthri yethu endaweni yethu yaseNew York ngaphambi kokuthunyelwa. Uma kwenzeka udinga ukuqaqa/ukuhlanganisa isibonakhulu sakho ngokuzayo, sicela ulandele imiyalelo echazwe ngezansi.
Lapho uhlanganisa isibonakhulu, qiniseka ukuthi zonke izingxenye azinalo uthuli nokungcola, futhi ugweme ukunwaya noma yiziphi izingxenye noma ukuthinta indawo yengilazi.I-ACCU-SCOPE EXC-500 Microscope - IZIQINISEKISO 3

UMHLANGANO WOMNiningwane

Ukufaka i-Condenser & Stage Inkampani yenethiwekhi - (Fig. 1 & 2)
Usebenzisa isikrufu esingu-3mm Hex esinikezwe ngesibonakhulu sakho, khulula isikulufu sokukhiya ①.
Shelelisela ngobumnene i-dovetail ye-condenser/stagi-e carrier phezu kwe-dovetail slide mount ② njengoba kubonisiwe ize ihlale iqinile kubhawodi eliphumule ③.
Phinda uqinise isikulufu sokukhiya ngesikrufu se-Hex.I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 1

Ukufaka i-Condenser - (Fig. 2 & 3)
Yehlisa i-condenser/stagI-e carrier ① endaweni yayo ephansi kakhulu ngokuphendula i-condenser knob iphikisana newashi ②.
I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 2Khulula isikulufu se-condenser lock nge-Hex wrench③.
Misa ikhondensa ④ iphinikhodi emaphakathi ibheke ngemuva kwesilayida se-dovetail. Shelelezisa i-condenser endaweni bese uyinyakazisa ukuze uqinisekise ukuthi iphinikhodi yokuma ibanjiwe.
Ngomusa qinisa kabusha isikulufu sokukhiya ③. I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 3

Ukufaka i-Stage – (Fig. 4 & 5)
Nge-condenser/stage ophethe endaweni ephansi kakhulu, susa itheyiphu yokuzivikela kanye nesikhwama ku-stage kanye nesibambi sesifanekiso ①.
(I-stagi-e iza nesibambi sesifanekiso esifakwe ngaphambili phezulu kwe-stagfuthi).
Usebenzisa i-3mm Hex wrench, khulula isikulufu sokukhiya ② ngaphambili kwe-stage.
Misa amafindo okunyakaza e-XY kwesokudla ③. Qondanisa intaba eyindilinga phansi kwe-stage nebakaki esiyindilinga ku-condenser/stage ophethe bese usetha u-stage endaweni ukuze igxile phezu kwe-condenser engezansi.
Phinda uqinise isikulufu sokukhiya ② ngaphambili kwe-stage. I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 4

Ukufaka i-Nosepiece - (Fig. 6)
Khumula amapulaki othuli ekhaleni ① ngenani lezinjongo ozobe uzifaka.
Usebenzisa isikrufu se-Hex, khulula isikulufu sokukhiya ② ngokwanele ukuze ucezu lwekhala lukwazi ukushelela kalula kunotshi ③ ngaphambili kwe-dovetail mount ④, bese uslayida ucezu lwekhala phezu kwentaba.
Phinda uqinise isikulufu sokukhiya ② ngesikrufu se-Hex. I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 5

Ukufaka i Viewing Head - (Fig. 7)
Ukusebenzisa isikrufu se-Hex khulula isikulufu sokukhiya ①.
Beka i- viewinhloko ② ngaphezu kokuvuleka kwe-dovetail ③ njengoba kubonisiwe futhi ilitshekele kancane phansi kwesokudla, slayida i-dovetail ngaphansi kwezinotshi embotsheni yejuba bese ulibeka endaweni amashubhu amabili e-eyepiece ④ ebheke phambili.
Phinda uqinise isikulufu sokukhiya ①.I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 6

Ukufaka ama-Eyepieces - (Fig. 8 & 9)
Susa ngokucophelela ama-eyepiece ① ephaketheni eliyisivikelo – qiniseka ukuthi ungathinti noma yiziphi izindawo ezikhanyayo (ingilazi). Susa izigqoko zothuli.
Faka i-eyepiece ① kwelinye lamashubhu we-eyepiece ② bese usonta kahle bese ucindezela i-eyepiece kuze kube yilapho icwebezela ngaphezulu kweshubhu lecezu leso.
Phinda ngenhla ukuze uthole omunye ucezu lwamehlo.

I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 7 I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 8

Ukufaka Izinjongo - (Fig. 10)
Zungezisa ifindo lokugxila elimahhadla ① ukuze wehlise u-stage endaweni yayo ephansi kakhulu.
Faka izinjongo kucezu lwekhala ② ukusuka ekukhuliseni okuphansi ukuya phezulu kakhulu ngendlela yewashi uqala ngesitsha sokuqala esingenalutho esingenanjongo ngaphambili.
Faka inhloso ngayinye ngokusebenzisa izandla ezimbili ukuze ubeke futhi ugoqe ngobumnene inhloso ngendlela yewashi emicu yento yokwamukela ikhala.
QAPHELA: Ungalokothi uphoqe noma yiziphi izinjongo emiculweni yekhala, futhi ungaqinisi kakhulu.I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 9

Ukufaka i-LED Lamp Izindlu - (Fig. 11)
Ukusebenzisa isikrufu se-Hex khulula isikulufu sokukhiya ① se-LED lamp izindlu.
Qondanisa futhi ufake i-lamp izindlu ② ngokuvula ③ ngemuva kwesitendi njengoba kukhonjisiwe.
Phinda uqinise isikulufu sokukhiya ①.
Qondanisa ichashazi elibomvu ku-LED lamp ipulaki yekhebula lendlu ④ elinechashaza elibomvu phezulu ku-lamp imbobo yezindlu ⑤ ngemuva kwesibonakhulu bese uslayida ipulaki ethekwini ukuze uthole ukukhanya okudluliselwe (). I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 10

Ukufaka Intambo Yamandla - (Fig. 12)
Qondanisa futhi uxhume isiphetho sowesifazane ① sentambo yamandla kusokhethi yentambo yamandla② ngemuva kwesibonakhulu.
Xhuma esinye isiphetho endaweni esekelwe phansi (3-prong).
QAPHELA: Njalo sebenzisa intambo yamandla ehlinzekwa ngesibonakhulu sakho; ukusebenzisa intambo yamandla ehlukile kungalimaza isibonakhulu sakho. Uma udinga omunye esikhundleni, xhumana nomthengisi wakho ogunyaziwe we-ACCU-SCOPE noma ushayele i-ACCU-SCOPE kokuthi 1-631-864-1000 kumthengisi oseduze nawe.I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 11

UKULUNGISWA NOKUSEBENZA

Iyavula - (Umdwebo 13)
Uma isibonakhulu sixhunyiwe, thola bese ucindezela inkinobho yokuguqula ye-I/O ① ngemuva kwesibonakhulu uye endaweni ethi VULA (I).
I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 12

Ukukhanyisa Isibani Se-LED Nokulungisa Ukukhanya - (Umfanekiso 14)
Cindezela inkinobho ethi Vula/Vala isibane ukuze uvule ukukhanya okudlulisiwe ①.
Lungisa ukukhanya ngokuguqula I-Iluminator Adjustment Knob ② ihambisane newashi ukuze uthole ukukhanya okugqamile, phikisana newashi ukuze uthole ukukhanya okuncane.I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 13

Ukubeka Isifanekiso - (Fig. 15)
Phusha ohlangothini lwesobunxele lwesibambi se-Special ① phezulu kwe-stagindawo yokuvula isibambi. Faka isilayidi sakho phakathi bese ukhulula isibambi ukusivumela ukuthi sivale ngokuqinile ngokumelene ne-slide. I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 14

Ukushintsha i-Stage Ukungezwani - (Fig. 16)
I-stagI-e control tension ingalungiswa ngokuya ngokuthandwa ngumsebenzisi. Ukuze ulungise ukushuba, donsela phansi u-Stage I-Movement Knob ① phansi ukuze uveze amasongo okulungisa ukungezwani ② ekuqondeni kwe-XY.
Ukuze uxegise, vula iringi ngayinye iphikisana newashi, noma ngokwewashi ukuze uqinise.
Phusha ifindo elingezansi liye phezulu uma ufinyelela ku-tension oyifunayo.I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 15

Ukulungisa Ibanga Le-Interpupillary - (Fig. 17)
Ukuze ulungise ibanga le-interpupillary, bamba amashubhu angakwesokunxele nakwesokudla ngenkathi ubuka isifanekiso. Zungezisa amathubhu azungeze i-eksisi emaphakathi kuze kube izinkambu ze view wawo womabili amathubhu ① aqondane ngokuphelele. Umbuthano ophelele kufanele ubonakale ku- viewing field nini viewnge-slide yesifanekiso. Ukulungiswa okungalungile kuzodala ukukhathala komsebenzisi futhi kuzophazamisa i-parfocality yenhloso.
Lapho okuthi “●” ② emigqeni yeshubhu ye-eyepiece kuze kufike esikalini se-interpupillary ③, leyo inombolo yebanga le-interpupillary. Ububanzi: 47-75mm.
Khumbula inombolo yakho ye-interpupillary ukuze usebenze esikhathini esizayo.
QAPHELA: Amashubhu we-eyepiece angazungeziswa ngo-180° ukuze kukhuliswe ubude bephoyinti leso ngo-34mm ukuze kuhlangatshezwane nezidingo zabasebenzisi abahlukene. I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 16

Ukulungisa Indlela Yokukhanya - (Fig. 18)
(Okokuzithandela kwe-Trinocular Viewing Heads)
Okwe-trinocular viewamakhanda, imbobo yekhamera yakho ikuvumela ukuba view 100% ngokusebenzisa ama-eyepiece, 20/80% kuya ku-eyepiece/ikhamera, noma 100% ngokusebenzisa imbobo yekhamera.
Ukuze ulungise indlela yokukhanya, cindezela Inkinobho Yokukhetha Indlela Yokukhanya ① ngaphakathi noma ngaphandle ukuze ukhethe okufunayo. viewindlela.I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 17

Isikhundla se Knob  Indlela ye-Eyepiece  Indlela Yembobo Yekhamera 
Indlela yonke phakathi 100% 0%
I-half-way in 20% 80%
Indlela yonke yokuphuma 0% 100%

Ukulungisa Ukugxila - (Fig. 19)
Ukuqinisekisa ukuthi uthola izithombe ezicijile ngawo womabili amehlo (njengoba amehlo ehluka, ikakhulukazi kulabo abagqoke izibuko) noma yikuphi ukuhluka kwamehlo kungalungiswa ngale ndlela elandelayo: setha womabili amakholomu e-diopter ukuze athi “0”. Usebenzisa iso lakho langakwesokunxele kuphela kanye nenjongo engu-10X, gxilisa isifanekiso sakho ngokulungisa iknobhu yokulungisa emahhadla ①. Uma isithombe singaphakathi view, cwenga isithombe ukuze sigxile kakhulu ekugxiliseni kwaso ngokuphendula iknobhu yokulungisa ecolekile ②. Zungezisa ikhola ye-diopter ukuze uthole ukugxila okucijile. Ukuze uthole isithombe esifanayo esicijile usebenzisa iso lakho langakwesokudla, ungathinti amaholoholo noma ukulungisa okuhle. Kunalokho, zungezisa ikhola ye-diopter engakwesokudla kuze kuvele isithombe esibukhali kakhulu. Phinda izikhathi ezimbalwa ukuze uhlole.
QAPHELA: ungaphikisani zungezisa inkinobho yokugxilisa ingqondo njengoba lokhu kuzodala izinkinga ezinkulu kanye nomonakalo ohlelweni lokugxila.I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 18

Ukulungisa I-Focus Stop - (Fig. 20)
Uma usulungise ukugxilisa ingqondo, phendula ukugxilisa kume njengokuhamba kwewashi ukuze usethe amaleveli akho omgomo abe endaweni yokuma ukuze angathintani nesilayidi sakho. I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 19

Ukumisa i-Condenser - (Fig. 21-23)
Ukuphakama okuphezulu kwe-condenser kwakusethwe kuqala efektri.
Iyakwazi ukuguqulwa kusetshenziswa amafindo okulungisa i-condenser nhlangothi zombili zecondenser. Ukuze ulungise, landela izinyathelo ezingezansi.
Zungezisa noma yimaphi amafindo e-condenser ① ukuze uyiphakamise ifike endaweni ephezulu kakhulu.
Zungezisa inhloso engu-10x emzileni wokukhanya bese ugxilisa isifanekiso.
Zungezisa inkambu iris diaphragm yokulungisa ② ukuze ubeke insimu i-diaphragm ye-iris endaweni encane kakhulu.
Zungezisa i-condenser knob futhi ulungise isithombe ukuze sibe bukhali kakhulu.
Usebenzisa isikrufu se-Hex esinikeziwe, lungisa izikulufu zokulungisa ezimaphakathi ③ bese uhambisa isifanekiso phakathi nendawo yenkambu view.
Vula i-iris diaphragm kancane kancane. Uma isithombe siphakathi nendawo ngaso sonke isikhathi futhi sibhalwe emkhakheni we view, i-condenser ibekwe phakathi nendawo ngendlela efanele.
Ngaphambili kwe-condenser, khetha inombolo efana nelensi oyiphokophele.

I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 20I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 21I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 22

Ukulungisa i-Aperture Diaphragm -(Fig. 24)
Usayizi wokuvuleka uyanyuswa noma wehliswe ngokuzungezisa iringi ye-diaphragm ye-condenser ①. Lapho indawo ivaliwe, ukukhanya nokulungiswa kuyehla kodwa ukugqama nobubanzi bokugxila kuyenyuka. Uma i-diaphragm yokuvula ivuliwe, ukukhanya nokulungiswa kwanda; nokho, ukugqama nobubanzi bokugxilwa kuzo kuyancipha. Ngokufanelekile viewizimo zibeka indandatho yokuvula i-condenser diaphragm ukuze ihambisane nokukhuliswa kwenhloso endleleni yokubona. I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 23

"ECO" (Economy) Setting - (Fig. 25)
I-EXC-500 Microscope ifakwe isici sokuvala ngokuzenzakalela, noma imodi ye-"ECO", ukuze kulondolozwe impilo yesibani.
Imodi ye-ECO isebenza lapho isibonakhulu singagadiwe imizuzu eyishumi nanhlanu (15).
Inzwa ye-ECO ① itholakala ngaphambili kwesisekelo se-microscope. Ngenkathi ikumodi ye-ECO ukukhanya okubomvu kwenzwa ye-ECO kuzokhanya kanye njalo emizuzwaneni emithathu (3).
Ukuze uphinde wenze kusebenze ukukhanya, cindezela inkinobho ye-ECO ② kanye.
Ukuze UKHUBAZE isici se-ECO, cindezela bese UBAMBA inkinobho ye-ECO imizuzwana emithathu (3).
UKUZE UVUSE FUSHA isici se-ECO, CHOKOZA bese UBAMBA inkinobho ye-ECO imizuzwana emithathu (3).I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 24

Ukushintsha AmaFuse - (Fig. 26 & 27)
Idrowa lesibambi se-fuse litholakala ngaphansi kwesitsha sentambo yamandla e-AC ngemuva kwesibonakhulu.
Ukuze umiselele amafuse, vala amandla bese ukhipha isibonakhulu esiphuma odongeni bese usuka esitshalweni sentambo yamandla ngemuva kwesibonakhulu.
Faka inhloko encane eyisicaba (-) screwdriver phezulu ekhabetheni lesibambi se-fuse ① bese uslayida ngokucophelela ukuze livuleke ukuze uveze amafuse amabili.
(Umdwebo 27 ukhombisa view ngibheke phezulu kusukela phansi kusibonakhulu nekhabethe le-fuse livuliwe.)
Qaphela ukuthi ungaphuli ingilazi yanoma iyiphi yamafuse, faka ngobumnene i-screwdriver phezulu ngezimbobo ezingezansi zedrowa njengoba kukhonjisiwe bese uphushela i-fuse ngayinye phezulu ukuze uyisuse.
Faka esikhundleni amafuse ngamafuse angu-250v T2.5A, CAT# 500-3277
Shelelezisa idrowa lesibambi se-fuse ulibuyisele endaweni.

I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 25 I-ACCU-SCOPE EXC-500 Microscope - UMHLANGANO 26

IBHUBHU LE-LED: 3w S-LED
OKUFAKAYO: AV 100 ~ 240v 50/60Hz
IFUSE: 250v T2.5A

IMICIMBI

ViewImizimba I-binocular noma i-trinocular (0:100, 100:0, 80:20 split), 30° ethambekele ku-Siedentopf noma i-ergonomic (0° ukuya ku-35° i-engeli yokulungisa)
uhlobo viewikhanda, elijikelezayo 360 °; ukulungiswa kwebanga le-interpupillary 47-78mm.
Ukuzikhethela okuningi-viewamapulatifomu ayatholakala
Isistimu ye-Optical Infinity optical system, f = 200mm, anti-mold
Izinjongo Ukucushwa okujwayelekile kufaka i-NIS Infinity Corrected Plan 4x, 10x, 40xR* kanye namafutha angu-100xR* (*alayishwe intwasahlobo)
Iziqephu zamehlo Izinto zamehlo ezigxilile ze-WF10x/22mm ezinonogada bamehlo zikhiyelwe ngaphakathi ukuze kuvinjelwe i-tampi-ring; i-eyepiece yamukela i-26.5mm
i-reticle. Ongakukhetha okungu-15x kanye no-20x kuyatholakala
Ikhala Ibhola le-sextuple eliphendulwe ekhaleni elinezitobhi zokuchofoza okulungile ukuze kuqinisekiswe ukungena
Isistimu yokugxila Isistimu yokugxila ye-coaxial enokulawula ukushuba okuguquguqukayo kanye nokuma komkhawulo ophezulu ukuze kuvinjelwe ukulimala ngengozi kumaslayidi; konke
amagiya ensimbi, ithusi legiya elihle lokugxila
Yima I-aluminium ehlanganisiwe
Stage Mechanical stage nge-Gorilla glass insert kanye nezilawuli eziguquguqukayo zokungezwani; usayizi 302mm x 152mm nobubanzi bokunyakaza be-XY obungu-78mm x 54mm
I-Condenser I-Achromat swing-out condenser, NA 0.9/1.25 (2x—100x) endaweni yokubeka kanye nephinikhodi ene-iris diaphragm
Ukukhanyisa Ukukhanya kwe-LED engu-3 watt nge-variable intensity control; Isibani se-LED sikalwe amahora angaphezu kuka-25,000 wokusetshenziswa okuqhubekayo;
ugesi jikelele 110-240v
Izesekeli Ikhava yothuli, imanuwali yeziqondiso ifakiwe
Ongakukhetha
Izesekeli
Izinamathiselo ze-fluorescence; Okunamathiselwe kwisigaba sokuqhathanisa;
Izinjongo ze-NIS Plan achromat, okungapheli kulungisiwe: 2x, 20x, 50xR uwoyela, 60xR noma 100xR uwoyela nge-iris diagphragm;
Izinjongo ze-NIS S-Plan APO: 4x, 10x, 20x, 40xR, 100xR amafutha;
I-6-position phase umehluko we-turret condenser, izindawo ze-BF & DF: 10x, 20x 40x & 100x isigaba se-annuli; ama-condensers;
ama-reticles; i-gout kit; Isikhwama se-microscope
Iwaranti Iwaranti enomkhawulo yeminyaka emi-5 yezingxenye, abasebenzi kanye nezingxenye ze-elekthronikhi;
Iwaranti yonyaka ongu-1 kusibani se-LED

UKUXOXA IZINKINGA

Ngaphansi kwezimo ezithile, ukusebenza kwale yunithi kungase kuthinteke kabi ngezinye izici ngaphandle kwamaphutha. Uma inkinga ivela, sicela uphindeview uhlu olulandelayo futhi uthathe izinyathelo zokulungisa njengoba kudingeka. Uma ungeke ukwazi ukuxazulula inkinga ngemva kokuhlola lonke uhlu, sicela uxhumane nomthengisi wangakini ukuze uthole usizo.

OKUBONA

Inkinga Imbangela Isinyathelo Sokulungisa
Ubumnyama emaphethelweni noma ukukhanya okungalingani kwe view inkambu Ikhala elijikelezayo alikho endaweni yokuma kokuchofoza Zungezisa ikhala ukuze uchofoze ukuma ngokushwiba umgomo ngendlela efanele endleleni yokubona
Ukungcola noma uthuli phezu view inkambu Ukungcola noma uthuli ku-lens - i-eyepiece, i-condenser, inhloso, ilensi yokuqoqa noma isampula Hlanza ilensi
Ikhwalithi yesithombe esibi Ayikho ingilazi yekhava enamathiselwe kusilayidi
Ingilazi yekhava inkulu kakhulu noma izacile
Shelelisela mhlawumbe ubheke phansi
Uwoyela wokucwiliswa usenhloso eyomile (ikakhulukazi i-40xR)
Awekho uwoyela wokucwiliswa osetshenziswa ngenjongo ye-100xR
Amabhamuza omoya kuwoyela wokucwiliswa
Indawo ye-Condenser ivaliwe noma ivuleke kakhulu
I-Condenser ibekwe phansi kakhulu
Namathisela ingilazi yekhava engu-0.17mm
Sebenzisa ingilazi yekhava enogqinsi olufanele (0.17mm)
Phendula islayidi ukuze ingilazi yekhava ibheke phezulu
Hlola izinjongo, hlanza uma kunesidingo
Sebenzisa uwoyela wokucwiliswa
Susa amagwebu
Vula noma vala kahle
Beka i-condenser ngaphansi kancane kunomkhawulo ongaphezulu

IZINKINGA ZEZITHOMBE

Inkinga Imbangela Izinyathelo Zokulungisa
Isithombe siyanyakaza ngenkathi sigxilile Isifanekiso sikhuphuka sisuka ku-stage ebusweni
Ikhala elijikelezayo alikho endaweni yokuchofoza-ukumisa
Vikela isifanekiso kusibambi samaslayidi
Jikisa ikhala liye endaweni yokuchofoza-ukumisa
Isithombe siphuzi Lamp ukuqina kuphansi kakhulu
Isihlungi esiluhlaza asisetshenziswanga
Lungisa ukuqina kokukhanya ngokuzungezisa ukudayela kokulawula ukuqina kanye/noma i-iris diaphragm
Sebenzisa isihlungi esiluhlaza sasemini
Isithombe sikhanya kakhulu Lamp ukuqina kuphezulu kakhulu Lungisa ukuqina kokukhanya ngokuzungezisa ukudayela kokulawula ukuqina kanye/noma i-iris diaphragm
Ukukhanya okunganele Lamp ukuqina kuphansi kakhulu
Imbobo ye-diaphragm ivalwe kude kakhulu
Indawo yecondenser iphansi kakhulu
Lungisa ukuqina kokukhanya ngokuzungezisa ukudayela kokulawula ukuqina kanye/noma i-iris diaphragm
Vula kusilungiselelo esifanele
Beka i-condenser ngaphansi kancane kunomkhawulo ongaphezulu

IZINKINGA ZEMISEBENZI

Inkinga Imbangela Izinyathelo Zokulungisa
Isithombe ngeke sigxile ngezinjongo zamandla aphezulu Shelelisela ubheke phansi
Ingilazi yekhava iwugqinsi
Phendula isilayidi ukuze ingilazi yekhava ibheke phezulu
Sebenzisa ingilazi yekhava engu-0.17mm
Oxhumana nabo benhloso yamandla aphezulu bayashelela lapho beshintshwa kusukela kumpokophelo yamandla aphansi Shelelisela ubheke phansi
Ingilazi yekhava iwugqinsi
Ukulungiswa kwe-Diopter akusethiwe kahle
Phendula isilayidi ukuze ingilazi yekhava ibheke phezulu
Sebenzisa ingilazi yekhava engu-0.17mm
Lungisa izilungiselelo ze-diopter njengoba kushiwo esigabeni 4.3
Lamp ayikhanyi uma ivuliwe Awekho amandla kagesi
Lamp isibani sishile Ifuse iqhunyiswe
Hlola ukuxhumeka kwentambo yamandla
Shintsha isibani
Faka esikhundleni i-fuse
Ukushelela kokugxilisa ingqondo lapho usebenzisa ifindo lokugxila elimahhadla Ukulungiswa kwe-tension kusethwe phansi kakhulu Khulisa ukungezwani kumafindo okugxila
Ukugxila okuhle akusebenzi Ukulungiswa kwe-tension kusethwe phezulu kakhulu Khulula ukungezwani kumafindo okugxilisa ingqondo

AMANDENI

Sicela ukhumbule neze shiya isibonakhulu kukhishwe noma yiziphi izinjongo noma izicucu zamehlo futhi uhlale uvikela isibonakhulu ngekhava yothuli uma ingasetshenziswa.

INKONZO

Imakroskopu ye-ACCU-SCOPE angamathuluzi anembayo adinga isevisi ngezikhathi ezithile ukuze awagcine esebenza kahle futhi anxephezele ukugqokwa okuvamile. Uhlelo olujwayelekile lokugcinwa kokuvikela okwenziwa ngabasebenzi abaqeqeshiwe lunconywa kakhulu. Umsabalalisi wakho ogunyaziwe we-ACCU-SCOPE ® angahlela le sevisi. Uma kwenzeka kuba nezinkinga ezingalindelekile ngensimbi yakho, qhubeka kanje:

  1. Xhumana nomsabalalisi we-ACCU-SCOPE” othenge kuye isibonakhulu. Ezinye izinkinga zingaxazululwa kalula ngocingo.
  2. Uma kunqunywa ukuthi isibonakhulu kufanele sibuyiselwe ku-ACCU-SCOPE yakho aumsabalalisi noma ku-ACCU-SCOPE ® ukuze kulungiswe iwaranti, pakisha ithuluzi ebhokisini layo lokuqala lokuthumela le-Styrofoam. Uma ungasenalo leli khathoni, pakisha isibonakhulu kubhokisi elikwazi ukumelana nokuchoboza elinamayintshi amathathu wento ebamba ukushaqeka elizungezile ukuze uvimbele umonakalo osendleleni. I-microscope kufanele isongwe ngesikhwama sepulasitiki ukuvikela uthuli lwe-Styrofoam ukuthi lungalimazi isibonakhulu. Ngaso sonke isikhathi thumela isibonakhulu sime endaweni eqondile; UNGALOKOTHI UTHUMELE ISIBONAKALISO ESABENI SASO. I-microscope noma ingxenye kufanele ithunyelwe isikhokhelwe futhi ifakwe umshwalense.

ISIQINISEKISO SESIBONAKALISO ESIKHAWULE

Le microscope kanye nezingxenye zayo ze-elekthronikhi kuqinisekisiwe ukuthi ayinazo iziphambeko ezintweni ezibonakalayo kanye nokusebenza isikhathi esiyiminyaka emihlanu kusukela osukwini lwe-invoyisi kuya kumthengi wangempela (umsebenzisi wokugcina). I-LED lamp ugunyazwe isikhathi esingangonyaka kusukela ngosuku lwe-invoyisi ukuya kumthengi wangempela (umsebenzisi wokugcina). Lesi siqinisekiso asibandakanyi umonakalo obangelwe kwezokuthutha, ukusetshenziswa kabi, ukunganakwa, ukuhlukumeza noma ukulimala okubangelwa isevisi engafanele noma ukuguqulwa ngabanye ngaphandle kwezisebenzi zesevisi ezigunyaziwe ze-ACU-SCOPE. Lesi siqinisekiso asibandakanyi noma yimuphi umsebenzi ojwayelekile wokulungisa noma yimuphi omunye umsebenzi, okulindeleke ngokunengqondo ukuthi wenziwe umthengi. Ukugqokwa okujwayelekile akufakiwe kulesi siqinisekiso. Asikho isibopho esithathwayo ngokusebenza okungagculisi ngenxa yezimo zemvelo ezinjengomswakama, uthuli, amakhemikhali abolayo, ukubekwa kukawoyela noma olunye udaba lwangaphandle, ukuchitheka noma ezinye izimo ezingaphezu kokulawulwa kwe-ACCU-SCOPE INC. Lesi siqinisekiso asibandakanyi noma yisiphi isibopho nge-ACCUSCOPE INC. ngokulahlekelwa okuwumphumela noma ukulimala kunoma yiziphi izizathu, njengokuthi (kodwa kungagcini nje) ukungatholakali Komsebenzisi Wokugcina wemikhiqizo ngaphansi kwewaranti noma isidingo sokulungisa izinqubo zomsebenzi. Uma kwenzeka noma yikuphi ukonakala empahleni, ekubunjweni noma ezintweni zikagesi kwenzeka ngaphansi kwalesi siqinisekiso xhumana nomsabalalisi wakho we-ACCU-SCOPE noma i-ACCUSCOPE ku- 631-864-1000. Lesi siqinisekiso sikhawulelwe ezwekazini lase-United States of America. Zonke izinto ezibuyiswe ukuze zilungiswe iwaranti kufanele zithunyelwe izimpahla zikhokhelwa kusengaphambili futhi zifakwe umshwalense kwa-ACCU-SCOPE INC., 73 Mall Drive, Commack, NY 11725 - USA. Konke ukulungiswa kwesiqinisekiso kuzobuyiselwa impahla ekhokhiwe kusengaphambili kunoma iyiphi indawo engaphakathi kwezwekazi lase-United States of America, kuzo zonke iziqinisekiso zokulungisa izinkokhelo zangaphandle zokubuyisela impahla kuwumthwalo womuntu/inkampani ebuyisele okuthengiswayo ukuze kulungiswe.

I-ACCU-SCOPE wuphawu lokuthengisa olubhalisiwe lwe-ACCU-SCOPE INC., Commack, NY 11725

Amadokhumenti / Izinsiza

I-ACCU-SCOPE 3000-LED Amandla Aphakeme We-Microscope [pdf] Incwadi Yeziqondiso
3000-LED Isibonakhulu Amandla Aphakeme, 3000-LED, Amandla Aphakeme Ngesibonakhulu, Amandla Aphezulu, Amandla
I-ACCU-SCOPE 3000 Isibonakhulu se-LED [pdf] Umhlahlandlela wokufaka
3000 Isibonakhulu se-LED, Isibonakhulu se-LED, Isibonakhulu
I-ACCU-SCOPE 3000 Isibonakhulu se-LED [pdf] Umhlahlandlela Womsebenzisi
3000 Isibonakhulu se-LED, 3000, Isibonakhulu se-LED, Isibonakhulu

Izithenjwa

Shiya amazwana

Ikheli lakho le-imeyili ngeke lishicilelwe. Izinkambu ezidingekayo zimakiwe *