I-AERCO TAG-0105B Boiler Ngaphambi kokufaka Umhlahlandlela Womsebenzisi Wokuklama Umoya kanye Nokushisa Umoya

AERCO TAG-0105B Boiler Pre Install Venting and Combustion Air Design Guide User Guide

I-AERCO-LOGO

I-AERCO TAG-0105B I-Boiler Pre-Install Venting kanye ne-Combustion Air Design

I-AERCO-TAG-0105B-Ibhoyili-Faka-Ngaphambi Kokungenisa-Nokushisa-Umklamo-Umkhiqizo-

Imininingwane

  • Amandla Okukhipha umoya: Umoya Ovuthayo Wegumbi, Ukukhipha Okuqondile; I-Ducted Combustion Air, Ukukhipha Okuqondile
  • I-Vent Material: Isigaba I sokungenisa umoya kuphela (Uhlobo B lokungenisa umoya)
  • Ukuthobela umthetho: Into esetshenziswa abalandeli Yesigaba I

Ulwazi Lomkhiqizo

Ibhayela yegesi ye-CFR iyiyunithi yokushisisa esetshenziswa abalandeli, eklanyelwe ukufudumeza ngendlela efanele. Kudinga ukunakwa ngokucophelela ekukhipheni umoya kanye nemininingwane yomoya ovuthayo ukuze kusebenze ngokuphephile. Izinto ezivunyiwe zokungenisa umoya ze-CFR Boiler zifaka i-Category I vesting, ikakhulukazi uhlobo B lwegesi. Izigaba II/III/IV zokungenisa umoya azifanele ukusetshenziswa nale bhayela. Unjiniyela wokuklama kanye nosonkontileka ofakayo banesibopho sokuqinisekisa ukuthi yonke imiklamo nokufakwa kwesistimu yokukhipha umoya kuhambisana nezinqubo ezingcono kakhulu zemboni, okuhlanganisa ukuphakama okufanele, ukusekela, kanye nokukhipha amanzi ukuze kuvinjelwe ukwehluleka. Ukucaciswa kwezinto ezivuthayo kumele kugcinwe ngokwe-UL kanye nezidingo zomkhiqizi wokukhipha umoya.

Imiyalo yokusetshenziswa komkhiqizo

I-Vent System Design kanye nokufakwa

Qinisekisa ukuthi idizayini yesistimu yokukhipha umoya ilandela izinqubo ezingcono kakhulu zomkhakha, okuhlanganisa ukuphakama okufanelekile, ukusekela, nokukhipha amanzi. Landela i-UL kanye nezimfuneko zomkhiqizi wokukhipha umoya ukuze kususwe izinto ezivuthayo.

Amandla okukhipha umoya

I-CFR Boiler ingafakwa umoya ovuthayo wegumbi noma umoya ovuthayo odonswayo, kokubili ngokukhishwa okuqondile. Qinisekisa ukufakwa ngendlela efanele ngokwendlela ekhethiwe yokukhipha umoya.

I-Combustion Air Supply

Ngekhwalithi yomoya ovuthayo, cabanga ukusebenzisa umoya ovuthayo ovela ngaphakathi kwebhilidi noma ovela ngaphandle kwesakhiwo ngokusekelwe kumhlahlandlela onikeziwe. Landela izimfuneko zokufaka zokungenisa umoya okuqondile.

Ukuthobelana Nokuphepha

Qinisekisa ukuthobela Ikhodi Kazwelonke Yegesi Yezibaso ANSI Z223.1 kanye nazo zonke izidingo zekhodi ezisebenzayo zokungenisa umoya kanye nezinhlelo zomoya ovuthayo ukuze kugcinwe ukusebenza okuphephile kwe-CFR Boiler.

FAQ

  • Q: Iluphi uhlobo lwempahla yokungenisa umoya oluvunyelwe ukusetshenziswa ne-CFR Boiler?
    • A: Kuphela Isigaba I sokungenisa umoya, ngokukhethekileyo uhlobo lwegesi lwe-B, olugunyazwe ukusetshenziswa ne-CFR Boiler. Izigaba II/III/IV zokungenisa umoya azifaneleki.
  • Q: Ubani onesibopho sokuqinisekisa ukuklanywa nokufakwa kwesistimu yokukhipha umoya ngendlela efanele?
    • IMP: Unjiniyela wokuklama kanye nosonkontileka ofakayo banesibopho sokuqinisekisa ukuthi yonke imiklamo nokufakwa kwesistimu yokukhipha umoya kuhambisana nezinqubo ezingcono kakhulu zomkhakha ukuze kuvinjelwe ukwehluleka.

Eminye imibhalo yalo mkhiqizo ihlanganisa:

  • Imanuwali yokufaka ye-OMM-0163
  • I-OMM-0164 Operation-Service Manual
  • TAG-0106 CFR Boiler Gas Umhlahlandlela
  • TAG-0107 Umhlahlandlela Wokufaka Isicelo Sebhoyili ye-CFR
  • TAG-0108 CFR Boiler Electrical Guide

Umshwana wokuzihlangula

Ulwazi oluqukethwe kuleli bhukwana lungase lushintshe ngaphandle kwesaziso esivela kwa-AERCO International, Inc. I-AERCO ayenzi siqinisekiso sanoma yiluphi uhlobo maqondana nalokhu kwaziswa, okuhlanganisa, kodwa kungagcini nje, iziqinisekiso ezishiwo zokuthengiselana nokufaneleka kohlelo oluthile. Ezinye izifundazwe azikuvumeli ukukhishwa noma ukukhawulwa komonakalo wengozi noma wemiphumela, ngakho umkhawulo ongenhla ungase ungasebenzi. I-AERCO International ayinasibopho ngamaphutha avela kuleli bhukwana, hhayi ngomonakalo wengozi noma wemiphumela owenzeka mayelana • nokunikezwa, ukusebenza, noma ukusetshenziswa kwalezi zinto.

JIKELELE

Ibhayela yegesi ye-CFR iyiyunithi eshisisa abalandeli, ene-hydronic enamandla alandelayo okungenisa umoya:

  1. I-Room Combustion Air, Ukukhipha Okuqondile
  2. I-Ducted Combustion Air, Ukukhipha Okuqondile

Kubalulekile ukuthi i-flue gas vent yakhelwe ukuvimbela ukuminyanisa ku-flue gas vent ukuze usebenze ngokuphephile. I-Condensation ingenzeka kubhayela we-CFR, ngaleyo ndlela ngayinye ifakwe isicupho sokususa i-condensate, njengoba kukhonjisiwe kuMfanekiso #, obonisa indawo yokungena komoya, ukuxhumeka kwe-vent kanye noxhumano lokususa i-condensate. Kodwa-ke, ngobuchwepheshe bayo obusengaphambili, i-boiler ye-CFR ihlale iletha igesi eyomile ukuze ikhiphe okuphephile ku-Category I venting. Le mihlahlandlela elandelayo ihlinzeka nge-latitude ebanzi ngenkathi ihlangabezana nezinjongo zokuphepha, ukuphila isikhathi eside nokusebenza okuphezulu.

IZINTO EZIVUMELEKILE ZOKUVUMA

KUBALULEKILE

Isigaba sokuqala kuphela esingasetshenziswa ne-CFR Boiler. Izigaba II/III/IV zokungenisa umoya azikwazi ukusetshenziswa.

I-CFR Boiler iwumshini osizwa abalandeli beSigaba I, esichazwa ku-National Fuel Gas Code ANSI Z223.1 “njengento esebenza ngomfutho we-nonpositive vent static kanye nezinga lokushisa legesi elikhipha umoya eligwema ukukhiqizwa kwe-condensate eyeqile endaweni yokukhipha umoya” , okudinga ukunakwa ngokucophelela ekukhipheni umoya kanye nemininingwane yomoya ovuthayo ukuze kusebenze ngokuphephile. Ibhayela ye-CFR ingase ifakwe umoya wohlobo B wegesi futhi idinga ukunakwa okucophelela edizayini yesistimu yokukhipha umoya nokusha. Kuyisibopho sikanjiniyela wokuklama kanye nosonkontileka ofakayo ukuqinisekisa ukuthi yonke imiklamo yesistimu yokukhipha umoya kanye nokufakwa ilandela izinqubo ezingcono kakhulu zomkhakha, okuhlanganisa ukuphakama okufanele, ukusekela, kanye nokukhipha amanzi ukuze kuvinjelwe ukwehluleka. Ukucaciswa okufanele kwezinto ezivuthayo kufanele kugcinwe nge-UL ngayinye kanye nezidingo zomkhiqizi wokukhipha umoya. I-UL, National Fuel Gas Code (ANSI Z223.1/ NFPA54)1 imihlahlandlela ngokuvamile iyisisekelo samakhodi esifunda nawendawo. Izincomo ze-AERCO zilandela imihlahlandlela yalezi zikhungo, ngaphandle kwalapho amakhodi aqinile abusa isayithi yokufaka. Amasistimu omoya wokungenisa umoya kanye nokushiswa kufanele ahlangabezane nazo zonke izimfuneko zekhodi ezisebenzayo.

Oshimula bamatshe 

Oshimula Bamatshe Bangaphandle, abachazwa njengoshimula bamatshe abavezwe ngaphandle ohlangothini olulodwa noma ngaphezulu ngaphansi komugqa wophahla, abakwazi ukusetshenziswa ngenxa yokulahlekelwa ukushisa okuphezulu okungathinta okusalungiswa okukhiqizwa ohlelweni. Lapho ungena koshimula bangaphakathi bamatshe, bheka futhi unamathele ekushicilelweni kwakamuva kwe-NFPA54 mayelana nempahla yolayini kashimula, usayizi, kanye nezimfuneko zokunqanyulwa. Uma usebenzisa ushimula okhona, kufanele ugunyazwe umshini we-Cat I, futhi uhlolwe/uhlanzwe ukuze kuqinisekiswe ukuthi uphilile futhi awuvaleki ukuze usebenze kahle. Uma isimo sikashimula okhona sithathwa njengesingafaneleki ukusetshenziswa, kufanele ulayiniwe, ulungiswe, noma ushintshwe ukuze uhambisane nokushicilelwa kwakamuva kwe-NFPA54.

IKHODI EDINGEKAYO UKUQEDWA KWE-VEENT

Imihlahlandlela enikezwe kulo mbiko kufanele ilandelwe ukuze kuthobelane nokushicilelwa kwakamuva kwe-UL, NFPA 54 (National Fuel Gas Code, ANSI Z223.1).
Ukunqanyulwa kwezikhala kufanele okungenani kube amafidi angu-4 (1.22 m) ngaphansi, unyawo olu-1 (0.30 m) ngaphezulu noma amafidi angu-4 (1.22 m) asuswe ngokuvundlile kunoma yiliphi iwindi, umnyango noma indawo yokungenisa umoya wesakhiwo. Ukunqanyulwa okunjalo kufanele kudlulele ngalé kobuso bangaphandle bodonga okungenani ngamayintshi angu-6 (15.2 cm). Iphansi lokunqanyulwa kokungenisa umoya kufanele okungenani libe ngamayintshi angu-12 (30.5 cm) ngaphezu kokubili kwebanga eliqediwe kanye nanoma yiliphi izinga eliphezulu lokunqwabelana kweqhwa ukuze kugwenywe ukuvimba indawo yokukhipha umoya noma ukungena komoya. Ukunqanyulwa kokungenisa umoya kufanele okungenani kube amafidi angu-3 (0.91 m) ngaphezu kwanoma iyiphi indawo engenisa umoya yesakhiwo phakathi kwamafidi angu-10 (3.05 m). Idizayini kufanele ivimbele amagesi e-flue ukuthi angaphinde ajikeleze ngokusebenzisa i-boiler air intake. Amapayipi akumele aphele ezindleleni zokuhamba zomphakathi noma izindawo lapho i-condensate noma umhwamuko ungadala inkathazo noma ube yingozi ekusebenzeni kwezilawuli, amamitha noma amathuluzi ahlobene. Okuphumayo akufanele kube ezindaweni ezinomoya omkhulu noma emakhoneni noma kubekwe ngemuva kwezitshalo. Ukukhishwa kulezi zindawo kungase kubangele ukuguquguquka komfutho we-flue futhi kubangele ukungazinzi kwelangabi. Ngokuvamile, imiklamo kufanele inciphise imiphumela yomoya. Ukungena ophahleni kufanele kulandele wonke amakhodi asebenzayo kanye neziqondiso zomkhiqizi wezikhala. Amapayipi akumele afakwe ngaphansi kokucaciswa okudingekayo ezintweni ezivuthayo, njengoba kubalulwe ku-UL, NFPA, noma amakhodi endawo. Ama-asembly “Double-wall” noma 'Thimble' ayadingeka lapho izintuba kungena ezindongeni ezivuthayo noma ophahleni. Ukukhishwa okuqondile kufanele kunwebe okungenani amafidi angu-3 (0.9 M) ngaphezu kophahla ngokungena okubaneke ngokufanelekile, futhi okungenani kube ngamafidi angu-2 (0.61 m) ngaphezu kwanoma iyiphi into ngaphakathi kwebanga elingu-10 (3.05 m) elivundlile. Izikrini ezinemeshi emikhulu zingasetshenziswa ekunqamulweni kokukhipha umoya ukuze kuvikelwe ekungeneni kwezinto zangaphandle, kodwa “indawo ekhululekile” kufanele okungenani ibe nkulu ngo-50% kunendawo enqamulayo edingekayo eyandulela ukunqanyulwa kwesikhala. Kunconywa ukuthi kusetshenziswe ukunqanyulwa kwe-T uma isikrini sifunwa. Ungasebenzisi izikrini zemeshi kumakhoni esivinini. Uma isistimu yokukhipha umoya izoxhunywa kusitaki esikhona, isitaki kufanele sihambisane ne-NFPA54. Izitaki zamatshe kufanele zifakwe ulayini, futhi ukungena kwe-vent kufanele kunqamule ukugudluzwa, futhi kuvalwe, kulo liner. Ama-vents angangena esitaki ngezansi noma ohlangothini. Konke okuxhunywe emaceleni kufanele kungene ekuxhumekeni okungama-degree angu-45 lapho kugeleza khona futhi kufanele kungene ezindaweni eziphakeme ezihlukene, ngoxhumano lwe-vent oluncane kakhulu endaweni ephakeme kakhulu. Ama-boiler vents e-CFR akumele axhunywe kwamanye amamodeli e-AERCO noma amathuluzi wabanye abakhiqizi. I-exhaust vent kufanele igxunyekwe phezulu ngasekuqedweni okungenani okuyiyintshi engu-¼ ngonyawo (21 mm ngemitha ngayinye). I-Condensate kufanele igeleze ibuyele kuyunithi ngokukhululeka, ngaphandle kokunqwabelana ku-vent.

I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (1)

UKUSUSWA KWE-CONNDENSATE

Ngenxa yokuthi ukujiya kungenzeka kubhayela we-CFR, iyunithi ngayinye ifakwe isicupho sokususa i-condensate. Ibhayela ye-CFR ihlale iletha igesi ewuketshezi eyomile ukuze ikhiphe umoya ophephile ku-Category I venting. Isistimu ye-exhaust vent kufanele ihlehliswe emuva ngaseyunithi ngobuncane obuyi-1/4 iyintshi ngonyawo (21 mm per m) yobude bepayipi ukuze i-condensate ikwazi ukudonsela emuva kuyunithi ukuze ilahlwe. Amachashazi aphansi endaweni yokungena kufanele agwenywe ukuvimbela ukuqoqwa kwe-condensate. Umhlangano we-condensate trap utholakala ngqo ngaphansi kwe-exhaust manifold. Ipayipi lepulasitiki kufanele lixhunywe kumhlangano wesicupho futhi ligijime ku-drain. Kumelwe kuqashelwe ukugwema ama-hose kinks futhi ugweme ukuphakamisa ipayipi ngaphezu kokuhlanganiswa komgibe. I-condensate kufanele igeleze ngokukhululekile ukuze ikhiphe. Ukugijima kwe-condensate-to-drain akumele kube ngamapayipi aqinile ukuze isicupho sisuswe ngezikhathi ezithile ngezinhloso zokunakekela. Uma i-condensate kufanele iphakanyiswe ngaphezu komhlangano wesicupho ku-drain, kufanele ikhishwe ibe yi-sump. Ukusuka lapho, iphampu ingaphakamisa i-condensate isuke.

Iyunithi ngayinye izokhiqiza amanani alandelayo e-condensate alandelayo:

  • CFR1500 = 9 amalitha ngehora
  • CFR3000 = 13 amalitha ngehora

Amasistimu wokudonsa amanzi e-condensate kufanele alinganiswe ngamanani okugeleza angaphezulu. Kumabhoyela amaningi asetshenziswayo, kuvamile ukuphindaphinda la madrayini ndawonye kumapayipi epulasitiki omningi kuya kumsele waphansi. Izinhlobonhlobo ze-condensate kufanele zibe zinkulu ngokwanele ukuphatha ukugeleza okulindelekile futhi kufanele zivikelwe kahle futhi zivikelwe. Ama-manifolds ngokuvamile atholakala ngemuva kwama-boilers ukuze izikhawu ezifushane zamashubhu epulasitiki angene ku-multifold zingasetshenziselwa ukukhipha i-condensate. I-base drain kumele ifakwe phansi kwepayipi elivamile eliqondile. Izinga le-pH le-condensate elikhiqizwa amabhayela e-CFR liphakathi kuka-3.0 no-3.2. Ukufakwa kufanele kuklanywe ngokuhambisana namakhodi endawo acacisa imikhawulo ye-pH eyamukelekayo. Uma kudingekile, noma yiluphi uhlobo lwe-neutralizer etholakala ngokuthengisa lungasetshenziswa. Qiniseka ukuthi ulandela imiyalelo yomkhiqizi we-condensate neutralizer.

UKUHLINZWA KOMOYA OVUTHAYO

Ama-Boilers e-CFR adinga amavolumu omoya ovuthayo alandelayo lapho esebenza ngokugcwele.

I-UNIT UMQULU ku-60°F (15.6°C)
I-CFR1500 325 SCFM (9.20 m3/min)
I-CFR3000 700 SCFM (19.82 m3/min)

Lokhu kugeleza KUMELE kufakwe. Ukunikezwa komoya kuyisidingo esiqondile se-NFPA54 kanye namakhodi endawo okufanele kuxhunyanwe nawo ukuze kusetshenziswe idizayini efanele

Ikhwalithi Yomoya Yomlilo

Emakamelweni ezinto ezisetshenziswayo aqukethe ezinye izinto ezisebenzisa umoya ― okuhlanganisa ama-compressor komoya nezinye izinto ezivuthayo - uhlelo lokuphakelwa komoya ovuthayo kufanele luklanywe ukuthwala zonke izinto ezinjalo lapho zonke zisebenza ngesikhathi esisodwa ngomthamo omkhulu.

Isexwayiso

Umoya ovuthayo kufanele ungabi nakungcola

Umoya ovunguzayo kumele ubekwe ezindaweni ezingeke zibangele ukuguquguquka komfutho womoya ovunguzayo ngokweqile (>0.10″ WC (25 Pa)). Imiklamo kufanele icabangele izifutho zemishini kanye nezikhipha umoya lapho kusetshenziswa umoya wegumbi ukuze kushiswe. Umoya ovunguzayo kumele ubekwe ukuze kuvinjelwe ukungena kwe-chlorine, ama-chloride, ama-halogen noma amanye amakhemikhali alimaza imishini yokushisa. Imithombo evamile yala makhemikhali amachibi okubhukuda, i-degreasinama-g compounds, usawoti wokuthambisa amanzi, ukucutshungulwa kwepulasitiki kanye nama-refrigerant. Lokhu kuzoqinisekisa ukuthi imishini ihlala isikhathi eside futhi kugcinwe ukuqinisekiswa kwewaranti.

Isexwayiso

Uma igumbi lezinto zokusebenza liseduze kwanoma yiliphi kulawa makhemikhali, kufanele linikezwe umoya ovuthayo ohlanzekile futhi libe nomfutho womoya wegumbi ovumayo, ohlinzekwa yisivunguvungu somoya esivuthayo esinamandla noma ipayipi, ukuvimbela ukungena kwamakhemikhali ekamelweni. .

Izindawo zokungenisa umoya akumele zibe seduze kwamagaraji, indawo yokungenisa umoya yezimboni nezokwelapha, amadokhu okulayisha noma imigqa yesiqandisi. Amabhola akumele afakwe eduze kwemisebenzi ekhiqiza uthuli uma lolo thuli lungangena kubhayela. Ama-boilers kufanele abekwe ukuze kuvinjelwe umswakama kanye nemvula ekungeneni kwama-air evuthayo.

Uma i-boiler isetshenziswa, okwesikhashana, ukunikeza ukushisa ngesikhathi sokwakhiwa kwesakhiwo okuqhubekayo noma ukulungiswa, uthuli oluqoqiwe lwe-drywall, sawdust kanye nezinhlayiya ezifanayo zinga:

  • Buthelela ekungeneni komoya ovuthayo kweyunithi futhi uvimbele ukugeleza komoya ovuthayo
  • Buthelela phezu kwendawo yokushisa bese ukhawulela ukuhamba komoya/ingxube yamafutha

Kulezi zimo, i-AERCO idinga ukuthi kufakwe isihlungi sokungenisa umoya esilahlwayo, okwesikhashana, ngaphezu kwendawo yokungena kubhayela evuthayo. Izihlungi zomoya zingase zidingeke unyaka wonke ezimweni lapho uthuli noma imfucumfucu ingangena eshubhu lomoya ovuthayo. Bheka Ibhukwana Lokusebenza Nelondolo ukuze uthole imininingwane. Amazinga okushisa omoya ovuthayo afinyelela ku -30 °F (-34.4 °C) angasetshenziswa ngaphandle kokuthikamezeka ubuqotho bempahla; kodwa-ke, izilungiselelo zokuvutha zingadinga ukulungiswa ukuze kunxeshezelwe izimo zesayithi.

UKUPHUMA KANYE NEZINKETHO ZOMOYA OKUSHISAYO

Izibalo ezingezansi zibonisa umoya owamukelekayo nezakhiwo zokuvutha. Ukuthola umoya wegumbi noma ukusha komoya oshisayo ezindaweni ezishisayo, bheka iSigaba 8 salo mhlahlandlela.

I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (2)

QAPHELA:

  • Ezindaweni ezinomoya ophezulu, i-tee kufanele ifakwe endaweni yokungenisa umoya omusha. Umlenze we-tee uxhuma ekungeneni komoya ovuthayo.
  • Ohlangothini lwe-flue vent, i-tee noma ikhoni yokuphuma (ikhoni yesivinini) ingasetshenziswa esikhundleni sesivalo semvula ezindaweni ezinomoya ophezulu.
  • Amagatsha e-tee angaba ohlangothini oluvundlile noma oluqondile, njengoba kunqunywa umklami wesistimu nezimo zesayithi.

KUBALULEKILE

Okunye ukucupha, okungaveziwe kulo mhlahlandlela, kuyenzeka. Sicela uthinte omele i-AERCO yangakini noma ifekthri ukuze uthole izilungiselelo eziqondene nephrojekthi ethile yokukhipha umoya kanye nokushiswa komoya.

Izidingo Zokufaka Zokungena Kuvundlile

Ukunqanyulwa kokungenisa umoya kufanele kubekwe ngale ndlela elandelayo (bheka uMdwebo 6-2):

  • a. Indawo yokungenisa umoya ovuthayo kufanele ibe amafithi angu-3. (0.9 m) ngaphansi kwanoma iyiphi i-outlet engaphakathi kwama-10 ft. (3.1 m).
  • b. Imikhawulo eqondile izokwengeza okungenani ngamamitha angu-3. (0.9 m) ngaphezu kwendawo ephakeme kakhulu lapho idlula khona ophahleni lwesakhiwo futhi okungenani ngamamitha angu-2 (0.6 m) ngaphezu kwanoma iyiphi ingxenye yesakhiwo phakathi kwebanga elivundlile elingu-10 ft. (3.1 m). Izinqamuli ezinwebeka ngaphezu kwamamitha angu-2 ngaphezu kophahla kufanele zisekelwe eceleni.
  • c. Indawo yokungenisa umoya ovuthayo kufanele futhi ibheke kude ne-outlet.
  • d. Sebenzisa isivalo somkhiqizi wamapayipi okukhipha umoya noma ikhoni yokuphuma (ikhoni yesivinini), into yokucima umlilo, ikhola yokusekela, i-flushing nekhololo yesiphepho.
  • e. I-AERCO incoma ukusetshenziswa kwekhoni yokuphuma esikhundleni sesivalo semvula sokunqanyulwa ekufakweni okujwayelekile kanye nokunqanyulwa kweT ezindaweni ezinomoya ophezuluI-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (3)

ISEXWAYISO

Ungawavikeli noma ugoqe ipayipi lokungenisa umoya noma izifakelo. Landela imiyalelo yokufaka umkhiqizi wamapayipi okukhipha umoya kanye namakhodi endawo wokungenisa umoya oqondile.

I-VENT & COMBUSTION AIR SYSTEM DESIGN

Amasayizi amancane okukhipha umoya ami kanje:

Imodeli I-Combustion Air Duct Min. Ububanzi I-Exhaust Vent Diameter
I-CFR1500 6 amayintshi (15.2 cm) Ungasebenzisi usayizi wokuxhuma kwesikhala somshini njengosayizi omncane wokungenisa umoya. Bheka kuhlelo lwakamuva lwe-NFPA 54/ANSI Z223.1

ukuze wenze usayizi wezinhlelo zesigaba I.

I-CFR3000 8 amayintshi (20.3 cm)

Imbobo yokuhlola ukuvutha engu-1/4-intshi (6.35 mm) ye-NPT inikezwa ekuxhumekeni kweyunithi ngayinye yokukhipha izinto eziningi. Isistimu yokukhipha umoya kufanele njalo imiswe inyuke ngo-1/4 iyintshi ngonyawo (21 mm per m) wokugijima ukuya lapho kunqanyulwa khona umoya ukuze i-condensate idonse ibuyele kuyunithi ukuze ilahlwe. Izindawo eziphansi endaweni yokungena kufanele zigwenywe. Ukuhlolwa ngezikhathi ezithile kufanele kwenziwe ukuze kuqinisekiswe ukugeleza kwamanzi ngendlela efanele. Ama-boiler vents e-CFR akumele axhunywe kulawa amanye amamodeli noma izisetshenziswa zabanye abakhiqizi. I-vent evundlile kanye ne-ductwork kufanele kusekelwe ukuze kuvinjelwe ukuhlehlisa, ngokuhambisana nekhodi yendawo kanye nezidingo zomkhiqizi we-vent. Imbobo eqondile kanye ne-ductwork kufanele isekelwe ukuze kuvinjelwe ingcindezi eyeqile ekugijimeni okuvundlile. I-adaptha yomoya yokukhipha izinto eziningi eziningi kanye ne-inlet akumele neze isetshenziswe njengezinto ezisekela isisindo. Izisekelo kufanele zihlelwe, futhi isakhiwo sisonke esiklanyelwe ukuqinisekisa ukuthi izingcindezi ku-vent kanye nokuxhumeka komoya ovuthayo kuyancishiswa.

Isigaba se-Vent Starter

I-CFR Boiler ngayinye ihlinzekwa ngesiqalisi sokungenisa umoya okufanele sifakwe inkambu.I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (4)

Indololwane Ubuningi Nokuhlukana

Ubuningi ne-engeli yezindololwane namabanga aphakathi kwazo kungaba nomthelela ekukhishweni kwesistimu nezingcindezi zomoya ovuthayo, kanye nokuziphatha kwayo kwe-acoustic. Abaklami kufanele bacabangele ukunciphisa inani lezindololwane futhi bakhulise ibanga eliphakathi kwazo ekwakhiweni kwesakhiwo. Ukusetshenziswa kwama-engeli angaphansi kuka-90° kuyanconywa noma nini lapho kunokwenzeka. Izindololwane ezinhlanu noma ezimbalwa ziyanconywa ngokugijima okukodwa kokukhipha umoya; ezinhlanu noma ngaphansi zinconywa ngokufanayo ezigabeni ezivamile. Ekugijimeni kwe-flue kanye ne-combustion air ducting, izindololwane kufanele zihlale zihlukene ngangokunokwenzeka. Lapho izindololwane eziseduze zingenakugwenywa, i-factory review kunconywa ukunquma ukuthi izinguquko zidinga ukwenziwa.

UMTHOMBO WOKUSHISA komoya

Umoya Ovuthayo Ovela Ngaphakathi Kwesakhiwo

Lapho umoya ovuthayo uzovela ngaphakathi kwesakhiwo, umoya kufanele unikezwe ekamelweni lemishini kusukela ezimbotsheni ezimbili ezihlala unomphela ukuya ekamelweni elingaphakathi (noma amagumbi). Ukuvuleka okuxhuma izindawo zasendlini kufanele kube nobukhulu futhi kubekwe ngokuhambisana nalokhu okulandelayo:

  • Ukuvula ngakunye kufanele kube nendawo yamahhala okungenani engu-1 inch2 nge-1,000 BTU/ihora ngalinye. (2,200 mm2/kW) yesamba sesilinganiso sokufakwayo sazo zonke izinto zikagesi ezisesikhaleni, kodwa hhayi ngaphansi kuka-100 inch2 (0.06 m2).
  • Ukuvuleka okukodwa kufanele kuqale phakathi kwamayintshi angu-12 (300 mm) ukusuka phezulu kwendawo ebiyelwe, futhi ukuvuleka okukodwa kufanele kuqale phakathi kwamayintshi angu-12 (300 mm) ukusuka phansi. (Bheka Umfanekiso 8-1: Wonke Umoya Ovuthayo Ovela Ezikhaleni Zangaphakathi Eziseduze).I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (5)

Umoya Ovuthayo Ovela Ngaphandle Kwesakhiwo

Umoya ovuthayo wangaphandle kufanele unikezwe ngokuvula ngaphandle ngokuhambisana nezindlela ezichazwe ngezansi. Ubukhulu obuncane bokuvuleka komoya akumele bube ngaphansi kwama-intshi angu-3 (76 mm). Usayizi odingekayo wezikhala zomoya ovuthayo kufanele usekelwe endaweni engenazo inetha yokuvuleka ngakunye. Lapho indawo yamahhala ngokusebenzisa i-louver, grille, noma isikrini saziwa, kufanele isetshenziselwe ukubala usayizi wokuvula odingekayo ukuze kuhlinzekwe indawo yamahhala eshiwo. Ukuze uthole imininingwane eyengeziwe, bheka ukushicilelwa kwakamuva kwe-NFPA 54.

Indlela Yokuvula Okuhlala Kabili (e-USA Kuphela)

Kufanele kuhlinzekwe izikhala ezimbili ezihlala unomphela; eyodwa iqala phakathi kwamayintshi angu-12 (304 mm) ngaphezulu kwendawo ebiyelwe futhi enye iqala phakathi kwamayintshi angu-12 (304 mm) ukusuka phansi. Izintuba kufanele zixhumane ngokuqondile ― noma ngamapayipi ― nangaphandle, noma izikhala ezixhumana ngokukhululekile nabangaphandle,

  1. Lapho uxhumana ngokuqondile nabangaphandle noma ngaphandle ngamapayipi aqondile, indawo ngayinye yokuvula kufanele ibe nendawo yamahhala engu-1 inch2 nge-BTU engu-4,000/h. (550 mm2/kW) yenani lokulinganisa lokufakwayo lazo zonke izinto zikagesi ezisesikhaleni (bheka uMfanekiso 8-2 kanye noMfanekiso 8-3).I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (6)I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (7)
  2. Lapho ukhuluma ngaphandle ngamapayipi avundlile, ukuvuleka ngakunye kufanele kube nendawo ekhululekile okungenani engu-1 intshi2 nge-2,000 BTU/ihora. (1100 mm2/kW) yenani lokulinganisa lokufakwayo lazo zonke izinto ezisetshenziswayo ezisesikhaleni.I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (8)

Indlela Eyodwa Yokuvula Unomphela

  • Isikhala esisodwa esihlala njalo kufanele sinikezwe, phakathi kwama-intshi angu-12 (300 mm) ukusuka phezulu kwendawo ebiyelwe.
  • Into esetshenziswayo kufanele ibe nendawo evulekile okungenani eyi-intshi engu-1 (25 mm) ukusuka ezinhlangothini nangemuva kwento esetshenziswayo, futhi ibe nendawo eyi-intshi engu-6 (150 mm) ukusuka ngaphambili.
  • Imbobo kufanele ixhumane nabangaphandle ngokuqondile noma ngomgudu oqondile noma ovundlile oya ngaphandle noma izindawo ezixhumana ngokukhululekile nabangaphandle futhi ibe nendawo yamahhala okungenani engu-1 inch2 nge-3,000 BTU/hr. (700 mm2/kW) yenani lokulinganisa lokufakwayo lazo zonke izinto ezisetshenziswayo ezitholakala esikhaleni.I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (9)

Ukuvula i-Louver Nge-CFR Boiler

I-louver ingavulwa kusetshenziswa oxhumana nabo abasizayo bokudlulisela kubhayela we-CFR. Laba abathintwayo banikezwa i-single pole double throw throw (SPDT) edluliswayo enikwa amandla uma kunesidingo sokushisa futhi ikhishwa amandla ngemva kokwaneliswa kwaleso sidingo. Oxhumana nabo abadluliswayo balinganiselwe ku-120 VAC ku-5 amps, ukumelana.
QAPHELA: Ungasiniki amandla i-louver ngokuqondile usebenzisa i-Axiliary Relay. I-relay yangaphandle (ayihlinzekiwe) kufanele isetshenziselwe le njongo. Amandla ebhayili awakwazi ukusekela izesekeli zangaphandle.

Uma i-louver ineswishi yokuqinisekisa ukuthi ivuliwe, kufanele ixhunywe kubhayela elibambezelekile. I-interlock ebambezelekile kufanele ivalwe ukuze iyunithi iqhume. Uma i-louver idinga isikhathi sokuvula, kufanele kuhlelwe ukubambezeleka kwesikhathi ukuze kubambe ukulandelana kokuqala kwebhayela isikhathi eside ngokwanele ukuze isishishi sokufakazela ukuthi sivuliwe (Ipharamitha: I-Aux Start On Delay — iyahleleka ukusuka ku-0 kuye ku-120 imizuzwana) . Uma iswishi yokuqinisekisa ukuthi ivuliwe ingabonakali phakathi nesikhathi esihleliwe, ibhayela izovalwa.
Ukuze uthole ukuxhunywa kwezintambo kanye nemininingwane eyengeziwe ephathelene ne-relay eyisizayo, ukukhiya okulibazisekayo kanye nepharamitha ye-Aux Start On Delay, bheka imanuwali ye-Operations and Maintenance.
Uma i-AERCO Control System (ACS) isetshenziselwa ukuphatha ukufakwa kukabhoyela okuningi, indawo yokuxhuma kufanele ivulwe kusetshenziswa i-System Start Relay ye-ACS. Bheka ku-ACS Operations and Maintenance Manual, GF-131, ukuze uthole ukuxhunywa kwezintambo kanye nemininingwane eyengeziwe.

I-Ducted Combustion Air

Ibhayela ye-CFR igunyazelwe ukufakwa komoya ovuthayo; okungukuthi, ingadonsa wonke umoya ovuthayo ophuma ngaphandle ngombhobho wensimbi noma we-PVC oxhunywe phakathi kwamayunithi e-CFR nangaphandle. Lokhu kulungiselelwa kuyasiza uma umoya wegumbi unganele noma ungakufanelekeli ukusha. Ubuncane bosayizi bepayipi lomoya ovuthayo okhishwa ngamabhoyili e-CFR bumi kanje:

  • I-CFR1500: 6-intshi ububanzi (15.2 cm)
  • I-CFR3000: 8-intshi ububanzi (20.3 cm)

Umoya ovuthayo ngokuvamile ungena kumabhayela e-CFR ngokusebenzisa i-air inlet engemuva kweyunithi. Amayunithi e-CFR 3000 anenketho yokufaka ikhithi ye-adaptha ye-air inlet eseceleni. Amakhithi amabili ayatholakala, amayunithi e-CFR 3000 kuphela:

  1. 58080-1 – 8″ Ikhithi ye-adaptha ye-Side Air Inlet
  2. 58080-2 – 10″ Ikhithi ye-adaptha ye-Side Air Inlet; idinga ukuvula okunwetshiwe kuphaneli eseceleni ukuze ilingane

Nge-CFR 1500 eseceleni yokungenisa umoya, sebenzisa iphethini yebhawodi eboniswe kuMfanekiso 8-6 ukuze ufake ipayipi lomoya ovuthayo.
Isikrini semeshi okungenani esingu-1” x 1” (2.54 mm x 2.54 mm) kufanele sifakwe endaweni yokungena yomgudu womoya. Bheka Isigaba 6 ngezinketho zokumisa umoya ovuthayo.

I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (10)

IZIMFUNO ZOKUKHULA KWE-VENT

Ikhithi ye-exhaust starter ehlanganisa ingxenye yesiqalisi se-vent kanye nesinyusi sihlinzekwa yi-AERCO ukuze ifakwe inkambu. Kufanele icaciswe lapho u-oda ibhayela ye-CFR. Izinketho yilezi:

  1. 8″ Flg x 10″ crimped (PN 99325-10). Sebenzisa lokhu uma Isigaba I sikhipha usayizi ukusuka kumathebula e-NFPA54 sidinga usayizi wokungena ngamunye noma usayizi wokuxhuma: 9″, 10″, 12″ kanye no-14″.
  2. 8″ Flg x 18″ crimped (PN 99325-18). Sebenzisa lokhu uma Isigaba I sikhipha usayizi ukusuka kumathebula e-NFPA54 sidinga usayizi wokungena ngamunye noma usayizi wokuxhuma: 16″, 18″, 20″ kanye no-22″.
  3. 10″ Ikhithi yesiqalisi se-Exhaust (P/N 24790-10: ingxenye engu-8” yesiqalisi se-vent kanye nesithuthukisi esingu-8” x 10”). Sebenzisa lokhu uma Isigaba I sikhipha usayizi ukusuka kumathebula e-NFPA54 sidinga usayizi wokungena ngamunye noma usayizi wokuxhuma: 9″, 10″, 12″ kanye no-14″.

KUBALULEKILE: Kuzinhlelo zokusebenza zokubuyisela kabusha, ukufaka esikhundleni sesistimu enenani elifanayo le-BTU eliphelele akusho ukuthi usayizi okhona wokukhipha umoya uzosebenza. Usayizi wokungena ngokuhambisana ne-NFPA54 njengesisetshenziswa esisizwa abalandeli beSigaba I ukuze kunqunywe usayizi olungile.

Amazinga Okucindezela Amukelekile

Kumayunithi aphumayo angawodwana, isistimu yokukhipha umoya kufanele yakhelwe ukuze ingcindezi elinganisiwe ibe phakathi kwebanga -0.01 ukuya -0.08″ wc Kumayunithi avamile afaka umoya, isistimu yokukhipha umoya kufanele yakhelwe ukuze ingcindezi elinganiselwe ibe phakathi kwebanga - 0.01 ukuze -0.08″ wc

IBarometric Damper

Ukuqinisekisa ukuthi uhla lwengcindezi olungenhla luyagcinwa, ibhayela ye-CFR idinga i-barometric dampizofakwa ngokushesha ngemva kocezu lwesiqalisi esihlinzekwe efekthri (bheka uMfanekiso 9-1). Ungasebenzisi usayizi woxhumano lwe-vent ukuze unqume usayizi we-barometric damper. Bheka kuhlelo lwakamuva lwe-NFPA 54/ANSI Z223.1 ukuze uthole usayizi wesistimu yokukhipha umoya Yesigaba I ukuze usayizi wokungena. Bese usebenzisa lobo bubanzi obufanayo ukuze usayizi we-barometric damper ezofakwa ngokushesha ngemva kokuba ifekthri inikeze ucezu lwesiqalisi. Bheka imiyalelo yomkhiqizi nge-barometric dampukufakwa, ukusebenza, nokugcinwa kwayo.I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (11)

Qeda Abalandeli

Ibhayela ye-CFR iyisisetshenziswa seSigaba I. Isistimu yokukhipha umoya kufanele yakhelwe ukuthi isebenze ngaphansi kwengcindezi engemihle. Kuphakanyiswa ukuthi lokhu kufezwe ngosayizi wesistimu ngokuvumelana nokushicilelwa kwakamuva kwe-National Fuel Gas Code (ANSI Z223.1/ NFPA54) njengesisetshenziswa esisizwa abalandeli beSigaba I. Uma isistimu yokukhipha umoya yebhayela ye-CFR ihlanganisa ifeni yokukhipha umoya, umklami wesistimu kufanele usayizi wamapayipi omoya, akhethe ifeni, futhi anqume indawo yenzwa yefeni ukuze agcine u--0.01 kuya ku- -0.08″ ububanzi be-wc endaweni yokukhipha ngayinye. ibhoyela. Futhi, umklami kufanele aqinisekise ukuthi okokusebenza kwefeni ye-exhaust kuyamukeleka ukuze kusetshenziswe izinto zikagesi zeSigaba I.

I-Gross Natural Draft

Amagesi alo anokuminyana okuphansi (futhi alula) kunomoya futhi azokhuphuka, enze “uhlaka lwemvelo oluphelele.” Isamba esisalungiswa semvelo sidalwa lapho amagesi aphuma emoyeni ephuma endaweni ephakeme ngaphezu kwebhayela ye-CFR. Inani lokusalungiswa lincike ekuphakameni kwesitaki kanye nomehluko phakathi kwezinga lokushisa le-flue gas kanye namazinga okushisa omoya azungezile (ukuminyana). Lapho ukala isistimu yokukhipha umoya ngokweKhodi Kazwelonke Yegesi Yamafutha (ANSI Z223.1/ NFPA54), okukhethiwe kucabangela uhlaka olukhiqiziwe. Xhumana nommeleli wakho wezokuthengisa we-AERCO noma i-AERCO International ukuze uthole usizo lokuklama nokugunyazwa lapho uklama amasistimu okukhipha umoya amaningi.

Ukulungiswa Kwe-Altitude

Lapho ulinganisa isistimu yokukhipha umoya ngokweKhodi Kazwelonke Yegesi Yamafutha (ANSI Z223.1/ NFPA54), amashadi ayo nemiyalo inikeza isiqondiso sendlela yokucabangela ukufakwa kokuphakama okuphezulu.
Ngohlelo lomoya ovuthayo, amathebula aseSigabeni 13.2 aklelisa izici zokulungisa zokufakwa kokuphakama ngaphezu kolwandle. Lezi zici kufanele zisetshenziswe kumathonsi okucindezela emigudu yomoya ovuthayo. Ukwehla kwengcindezi ngamapayipi omoya ovuthayo kuzokhuphuka ezindaweni eziphakeme

IZIHLELO ZOKUVUMA NGAMUNYE

Ibhayela ye-CFR isekela ukushiswa kwegumbi/ukuphuma okuqondile kanye nezilungiselelo zokushiswa/ukuphuma okuqondile. Isistimu yokukhipha umoya kufanele ilinganiswe ngokuhambisana nokushicilelwa kwakamuva kwe-National Fuel Gas Code (ANSI Z223.1/ NFPA54) njengesisetshenziswa esisizwa abalandeli beSigaba I. Kumayunithi afakwa umoya ngamunye, isistimu yokukhipha umoya kufanele yakhelwe ukuze ukucindezela kukalwe kube phakathi kwebanga elingu--0.01 ukuya ku- -0.08″ wc Xhumana nommeleli wakho wendawo wezentengiso we-AERCO ukuze uthole imihlahlandlela yokulinganisa komoya ovuthayo. Kufanele kuqashelwe ukuthi ukugeleza kanye ne-vent noma ububanzi be-duct kunemiphumela ebaluleke kakhulu ekwehleni kwengcindezi yesistimu iyonke. Uma kuzosetshenziswa ipayipi elingunxande, bheka ithebula eliseSigabeni 13.3 ukuze uthole usayizi wepayipi eliyindilinga elinokwehla okufanayo kokucindezela ngobude bepayipi elingunxande.

IZINHLELO EZIKHONAYO

KUBALULEKILE:

Xhumana nommeleli wakho wezokuthengisa we-AERCO noma i-AERCO International ukuze uthole usizo lokuklama futhi uphindeview lapho uklama i-exhaust ehlukahlukene kanye nezinhlelo zomoya ezivuthayo eziningi.

Ezimweni eziningi kungase kusebenze ukuxhuma amayunithi amaningi usebenzisa umoya odonsayo ophihliwe noma ukumiswa kokukhipha umoya. Kodwa-ke, lapho amayunithi amaningi exhunywe yisikhala somoya esiphindiwe noma isikhipha umoya, ukusebenza kweyunithi enikeziwe kungase kuthikamezeke ngamanye, uma isistimu yokungenisa umoya noma yokushiswa ingaklanywanga kahle. Amasistimu ajwayelekile aklanywe kahle ajwayelekile angafakwa azovimbela "ukusebenzelana kokusebenza" phakathi kwamayunithi. Ama-boilers asizwa abalandeli be-AERCO CFR aklanyelwe afaneleka ukusetshenziswa ezinhlelweni ezivamile zokungenisa umoya. Isistimu yokungenisa umoya evamile izolinganiswa ngokuhambisana nokushicilelwa kwakamuva kwe-National Fuel Gas Code (ANSI Z223.1/ NFPA54) njengento esetshenziswa abalandeli yeSigaba I. Kumayunithi avamile afaka umoya, isistimu yokukhipha umoya kufanele yakhelwe ngendlela yokuthi ingcindezi elinganiswa kuyo yonke indawo ibe yinegethivu, phakathi kwebanga elingu--0.01 ukuya -0.08″ wcThintana nommeleli wakho wendawo wezentengiso we-AERCO ukuze uthole imihlahlandlela yokulinganisa umoya ovuthayo.

Izindlela Ezinhle Kakhulu

Ukuxhuma emsebenzini ovamile wokubhodla amapayipi noma amapayipi kufanele kufezwe ngendololwane engu-45° lapho kugeleza khona lapho kubhodla umoya. "Ama-Tees" akumele asetshenziselwe ukufeza lokhu kuxhumana - bheka uMdwebo 11-1. Ubuncane obuncane obudingekayo bokungena kwembobo eqondile eqondile kufanele kube ngamafidi angu-10 (3.1 m) kuze kufike ekunqamulweni okume mpo ngemva kokuba ibhayili yokugcina ixhunywe kunhlokweni evamile.I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (12)

Ukuxhumana kwamaqembu amayunithi akumele neze kwenziwe “nge-tee”. Njengoba kukhonjisiwe kuMfanekiso 11-2, shintsha isiqondiso ngomunye wamapayipi amakhulu bese uxhuma ububanzi obuthathu besibili (ububanzi besigaba esivamile) ukusuka kuleli jika ngoxhumano lwama-45°.

I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (13)

Umfanekiso 11-3 ubonisa “isigaba sokushintsha kwesikhala” lapho wenza ukuxhumana okungu-45° kube okuyinhloko. I-main ingahlala futhi ku-diameter eyodwa, inqobo nje uma ilinganiswa nenani eliphelele lamayunithi aphumayo futhi ukuxhumana kwegatsha okungu-45° kugcinwa. Ukusetshenziswa komhlangano "woshintsho" onconyiwe kuzonciphisa ukwehla kwengcindezi yesistimu iyonke.I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (14)

Isistimu yokukhipha umoya kufanele njalo imiswe phezulu ngo-¼-intshi ngonyawo (21 mm per m) wokugijima ukuya lapho kunqanyulwa khona umoya (bona Umfanekiso 11-4). Kunconywa kakhulu ukusebenzisa usayizi wepayipi elilodwa lapho ugijima okuvamile (Bheka Umfanekiso 11). -4). Ama-boiler vents e-CFR akumele axhunywe kulawa amanye amamodeli e-AERCO noma izisetshenziswa zabanye abakhiqizi.I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (15)

Ukususwa Kwe-Boiler Ekhona Ekungeneni Okujwayelekile

Lapho ibhayela ekhona ikhishwa ohlelweni oluvamile lokungenisa umoya, isistimu yokungenisa umoya evamile ingase ibe nkulu kakhulu ukuze kungene umoya ofanele wezinto zikagesi ezisele zixhunywe kuyo. Ngesikhathi sokukhishwa kukabhayela okhona, izinyathelo ezilandelayo zizolandelwa ngesisetshenziswa ngasinye esisele sixhunywe ohlelweni oluvamile lokungenisa umoya olusetshenziswayo, kuyilapho ezinye izinto ezisasele zixhunywe ohlelweni oluvamile lokungenisa umoya zingasebenzi.

  1. Vala noma yiziphi izimbobo ezingasetshenzisiwe ohlelweni oluvamile lokungenisa umoya.
  2. Hlola ngokubuka isistimu yokukhipha umoya ukuze uthole usayizi ofanele kanye nevolumu evundlile futhi unqume ukuthi akukho ukuvinjelwa noma ukuvinjelwa, ukuvuza, ukugqwala noma okunye ukushiyeka okungaphephile.
  3. Ngokunokwenzeka, vala yonke iminyango yesakhiwo namafasitela kanye nayo yonke iminyango phakathi kwendawo lapho izinto zikagesi ezisele zixhunywe ohlelweni oluvamile lokungenisa umoya zikhona nezinye izikhala zesakhiwo. Vula okomisa izingubo nanoma yiziphi izinto zikagesi ezingaxhumene nesistimu evamile yokukhipha umoya. Vula noma yimaphi amafeni e-exhaust, njengama-hood ahlukahlukene kanye ne-exhauss yasendlini yangasese, ukuze azosebenza ngesivinini esiphezulu. Ungasebenzisi ifeni yokukhipha umoya ehlobo. Vala iziko dampabadala.
  4. Indawo yokusebenza into esetshenziswayo iyahlolwa. Landela imiyalelo yokukhanyisa. Lungisa i-thermostat ukuze into esetshenziswayo isebenze ngokuqhubekayo.
  5. Ukuhlola ukuchitheka kwempahla ekuvulekeni kwehod yokusalungiswa ngemva kwemizuzu emi-5 yokusebenza kokushisa okukhulu. Sebenzisa ilangabi lomentshisi noma ikhandlela, noma intuthu kagwayi, ugwayi, noma ipayipi.
  6. Ngemva kokunquma ukuthi umshini ngamunye osele uxhumeke kusistimu evamile yokukhipha umoya uphuma kahle umoya lapho uhlolwa njengoba kushiwo ngenhla, iminyango yokubuya, amafasitela, izifeni ezikhipha umoya, iziko dampers, kanye nanoma yisiphi esinye isisetshenziswa esishisa igesi esisesimweni saso sangaphambili sokusetshenziswa.

Noma yikuphi ukusebenza okungafanele kwesistimu yokukhipha umoya evamile kufanele kulungiswe ukuze ukufakwa kuhambisane Nekhodi Kazwelonke Yegesi Yezibaso, ANSI Z223.1/NFPA 54. Lapho ushintsha usayizi wanoma iyiphi ingxenye yesistimu yokukhipha umoya evamile, isistimu yokukhipha umoya evamile kufanele ishintshwe usayizi ukuze isondele ubuncane bosayizi njengoba kunqunywa kusetshenziswa amathebula afanelekile kuSahluko 13 SeKhodi Kazwelonke Yegesi Yamafutha, ANSI Z223.1/NFPA 54.

I-ExhaUST MUFFLER GUIDELINES

I-exhaust muffler iyatuswa uma ifakwe ohlelweni oluzwelayo umsindo nalapho i-exhaust vent ducting imfushane ngobude. Ungasebenzisi usayizi woxhumano lwe-vent ukuze unqume ubukhulu be-exhaust muffler. Bheka kuhlelo lwakamuva lwe-NFPA 54/ANSI Z223.1 ukuze uthole usayizi wesistimu yokukhipha umoya Yesigaba I ukuze usayizi wokungena, bese usebenzisa lobo bubanzi obufanayo ukuze usayizi we-muffler ezofakwa ngokushesha ngemva kwesiqephu sokuqala esinikezwe yifekthri.

Imibandela elandelayo kufanele isetshenziselwe ukunquma ukuthi sifakwa nini i-muffler efakwe ensimini:

  • I-exhaust ifakwe ngodonga oluseceleni futhi indawo yokungena iyanqanyulwa eduze nezindawo zokuhlala, amahhovisi, amagumbi ehhotela/esibhedlela, amagumbi okufundela njll.
    -NOMA-
  • Isamba sesigaba esime mpo nesivundlile sendawo yokukhipha umoya ingaphansi kwamamitha angu-25 alayini (7.6 m) ukusuka kuyunithi yokugcina, futhi indawo yokungena inqamuka eduze nezindawo zokuhlala, amahhovisi, amagumbi okufundela njll. Kuzinhlelo zokukhipha umoya omningi, ingqikithi yobude besigaba esime mpo ihlanganisa kokubili ukuma okuvundlile nokuvamile; izixhumi eziqondile ze-boiler ngayinye zifakiwe ekunqumeni futhi.
    EXAMPLE: Okufakwayo okunamafidi angu-20 (6 m) avamile aqondile, amafidi angu-5 (1.5 m) avamile avundlile ngemva kwebhayela yokugcina, futhi ibhayela ngayinye inesixhumi esima mpo esingamafidi angu-10 (3.1 m), isamba sobude besigaba esicatshangelwayo sithi 35 izinyawo (10.7 m). Ngenxa yokuthi lokhu kungaphezu kwamamitha angu-25, i-muffler ayidingeki. Xhumana nommeleli wakho wendawo wezokuthengisa we-AERCO ukuze uthole ulwazi olwengeziwe mayelana ne-AERCO exhaust muffler

AMATHEBULA EDATHA OKUQINISEKILEYO

I-Ducted Combustion Air Duct Pressure Drop

Ithebula 13-a: I-Ducted Combustion Air Duct Pressure drop in Eq. I-Ft. (m) ye-CFR1500 Boiler

  Ngaphandle Kwezinga lokushisa Lomoya ngaphakathi °F (°C)
I-Inlet Duct & No Umbhobho Ingxenye Uhlobo -30 °F (-

34.4)

-15 °F

(-26.1)

0 °F

(-17.8)

20 °F (-

6.7)

40 °F

(4.4)

60 °F

(15.6)

80 °F

(26.7)

100 °F

(37.8)

120 °F

(48.9)

 

 

6″ Umshini

 

I-Single Boiler

Ukusebenza okuqondile 0.98 1.00 1.02 1.06 1.09 1.13 1.16 1.20 1.24
(0.98) (1.00) (1.02) (1.06) (1.09) (1.13) (1.16) (1.20) (1.24)
90° Indololwane 4.97 5.21 5.47 5.84 6.23 6.64 7.09 7.56 8.07
(1.515) (1.588) (1.667) (1.78) (1.899) (2.024) (2.161) (2.304) (2.46)
45° Indololwane 3.78 3.97 4.17 4.44 4.74 5.06 5.4 5.76 6.14
(1.152) (1.21) (1.271) (1.353) (1.445) (1.542) (1.646) (1.756) (1.871)
Ent. Ukulahlekelwa 7.33 7.69 8.07 8.60 9.18 9.79 10.45 11.15 11.89
(2.234) (2.344) (2.46) (2.621) (2.798) (2.984) (3.185) (3.399) (3.624)
 

 

8″ Umshini

 

I-Single Boiler

Ukusebenza okuqondile 0.23 0.24 0.24 0.25 0.26 0.27 0.28 0.29 0.30
(0.23) (0.24) (0.24) (0.25) (0.26) (0.27) (0.28) (0.29) (0.30)
90° Indololwane 1.19 1.25 1.31 1.39 1.49 1.59 1.69 1.81 1.93
(0.363) (0.381) (0.399) (0.424) (0.454) (0.485) (0.515) (0.552) (0.588)
45° Indololwane 0.89 0.94 0.98 1.05 1.12 1.19 1.27 1.36 1.45
(0.271) (0.287) (0.299) (0.32) (0.341) (0.363) (0.387) (0.415) (0.442)
Ent. Ukulahlekelwa 2.32 2.43 2.55 2.72 2.90 3.10 3.31 3.53 3.76
(0.707) (0.741) (0.777) (0.829) (0.884) (0.945) (1.009) (1.076) (1.146)
 

 

10″ Umshini

 

Ama-boilers amabili

Ukusebenza okuqondile 0.24 0.25 0.26 0.28 0.30 0.32 0.34 0.36 0.38
(0.24) (0.25) (0.26) (0.28) (0.30) (0.32) (0.34) (0.36) (0.38)
90° Indololwane 1.60 1.68 1.77 1.88 2.01 2.14 2.29 2.44 2.60
(0.488) (0.512) (0.539) (0.573) (0.613) (0.652) (0.698) (0.744) (0.792)
45° Indololwane 1.21 1.27 1.33 1.42 1.51 1.61 1.72 1.84 1.96
(0.369) (0.387) (0.405) (0.433) (0.46) (0.491) (0.524) (0.561) (0.597)
Ent. Ukulahlekelwa 3.80 3.98 4.18 4.46 4.76 5.08 5.42 5.78 6.16
(1.158) (1.213) (1.274) (1.359) (1.451) (1.548) (1.652) (1.762) (1.878)
 

 

12″ Umshini

 

Ama-boilers amabili

Ukusebenza okuqondile 0.10 0.10 0.11 0.11 0.12 0.13 0.14 0.15 0.16
(0.10) (0.10) (0.11) (0.11) (0.12) (0.13) (0.14) (0.15) (0.16)
90° Indololwane 0.70 0.73 0.77 0.82 0.88 0.93 1.00 1.06 1.13
(0.213) (0.223) (0.235) (0.25) (0.268) (0.283) (0.305) (0.323) (0.344)
45° Indololwane 0.53 0.56 0.59 0.62 0.67 0.71 0.76 0.81 0.86
(0.162) (0.171) (0.18) (0.189) (0.204) (0.216) (0.232) (0.247) (0.262)
Ent. Ukulahlekelwa 1.83 1.92 2.02 2.15 2.29 2.45 2.61 2.79 2.97
(0.558) (0.585) (0.616) (0.655) (0.698) (0.747) (0.796) (0.85) (0.905)
 

 

12″ Umshini

 

Ama-boilers amathathu

Ukusebenza okuqondile 0.20 0.21 0.22 0.24 0.26 0.27 0.29 0.31 0.33
(0.20) (0.21) (0.22) (0.24) (0.26) (0.27) (0.29) (0.31) (0.33)
90° Indololwane 1.57 1.65 1.73 1.85 1.97 2.10 2.24 2.39 2.55
(0.479) (0.503) (0.527) (0.564) (0.6) (0.64) (0.683) (0.728) (0.777)
45° Indololwane 1.20 1.26 1.32 1.41 1.50 1.60 1.71 1.82 1.94
(0.366) (0.384) (0.402) (0.43) (0.457) (0.488) (0.521) (0.555) (0.591)
Ent. Ukulahlekelwa 4.12 4.32 4.54 4.84 5.16 5.51 5.88 6.27 6.69
(1.256) (1.317) (1.384) (1.475) (1.573) (1.679) (1.792) (1.911) (2.039)
  Ngaphandle Kwezinga lokushisa Lomoya ngaphakathi °F (°C)
I-Inlet Duct & No Umbhobho Ingxenye Uhlobo -30 °F

(-34.4)

-15 °F

(-26.1)

0 °F

(-17.8)

20 °F

(-6.7)

40 °F

(4.4)

60 °F

(15.6)

80 °F

(26.7)

100 °F

(37.8)

120 °F

(48.9)

 

 

14″ Umshini

 

Ama-boilers amathathu

Ukusebenza okuqondile 0.09 0.10 0.10 0.11 0.12 0.13 0.14 0.14 0.15
(0.09) (0.10) (0.10) (0.11) (0.12) (0.13) (0.14) (0.14) (0.15)
90° Indololwane 0.82 0.86 0.9 0.96 1.02 1.09 1.17 1.24 1.33
(0.25) (0.262) (0.274) (0.293) (0.311) (0.332) (0.357) (0.378) (0.405)
45° Indololwane 0.63 0.66 0.70 0.74 0.79 0.85 0.90 0.96 1.03
(0.192) (0.201) (0.213) (0.226) (0.241) (0.259) (0.274) (0.293) (0.314)
Ent. Ukulahlekelwa 2.22 2.33 2.45 2.61 2.79 2.97 3.17 3.38 3.61
(0.677) (0.71) (0.747) (0.796) (0.85) (0.905) (0.966) (1.03) (1.100)
 

 

14″ Umshini

 

Ama-boilers amane

Ukusebenza okuqondile 0.16 0.17 0.18 0.19 0.2 0.22 0.23 0.25 0.26
(0.16) (0.17) (0.18) (0.19) (0.20) (0.22) (0.23) (0.25) (0.26)
90° Indololwane 1.45 1.53 1.60 1.71 1.82 1.94 2.07 2.21 2.36
(0.442) (0.466) (0.488) (0.521) (0.555) (0.591) (0.631) (0.674) (0.719)
45° Indololwane 1.12 1.18 1.24 1.32 1.41 1.50 1.60 1.71 1.83
(0.341) (0.36) (0.378) (0.402) (0.43) (0.457) (0.488) (0.521) (0.558)
Ent. Ukulahlekelwa 3.95 4.15 4.35 4.64 4.95 5.29 5.64 6.02 6.42
(1.204) (1.265) (1.326) (1.414) (1.509) (1.612) (1.719) (1.835) (1.957)
 

 

16″ Umshini

 

Ama-boilers amane

Ukusebenza okuqondile 0.08 0.09 0.09 0.10 0.10 0.11 0.12 0.13 0.13
(0.08) (0.09) (0.09) (0.10) (0.10) (0.11) (0.12) (0.13) (0.13)
90° Indololwane 0.84 0.88 0.93 0.99 1.06 1.13 1.20 1.28 1.37
(0.256) (0.268) (0.283) (0.302) (0.323) (0.344) (0.366) (0.39) (0.418)
45° Indololwane 0.66 0.69 0.73 0.78 0.83 0.88 0.94 1 1.07
(0.201) (0.21) (0.223) (0.238) (0.253) (0.268) (0.287) (0.305) (0.326)
Ent. Ukulahlekelwa 2.32 2.43 2.55 2.72 2.9 3.10 3.31 3.53 3.76
(0.707) (0.741) (0.777) (0.829) (0.884) (0.945) (1.009) (1.076) (1.146)

AMANOTHI:

  1. Isibalo sithatha 300 SCFM (8.49 m3/min) kubhayela ngamunye ngenani eligcwele lomlilo
  2. Amayunithi amanani ehla ingcindezi ethi “Straight Run” ayizinyawo ezilinganayo ngonyawo ngalunye (eq. m / m)
  3. Amayunithi "ama-Elbows" kanye "ne-Ent. Ukulahlekelwa” amafidi alinganayo ngento ngayinye (eq. m / into)

Ithebula 13-b: I-Ducted Combustion Air Duct Pressure drop in Eq. I-Ft. (m) ye-CFR3000 Boiler

  Ngaphandle Kwezinga lokushisa Lomoya ngaphakathi °F (°C)
I-Inlet Duct & No Umbhobho Ingxenye Uhlobo -30 °F (-

34.4)

-15 °F

(-26.1)

0 °F

(-17.8)

20 °F (-

6.7)

40 °F

(4.4)

60 °F

(15.6)

80 °F

(26.7)

100 °F

(37.8)

120 °F

(48.9)

 

 

8″ Umshini

 

I-Single Boiler

Ukusebenza okuqondile 0.85 0.87 0.89 0.91 0.94 0.97 1.00 1.03 1.06
(0.85) (0.87) (0.89) (0.91) (0.94) (0.97) (1.00) (1.03) (1.06)
90° Indololwane 4.75 4.98 5.23 5.58 5.95 6.35 6.77 7.23 7.71
(1.448) (1.518) (1.594) (1.701) (1.814) (1.935) (2.063) (2.204) (2.35)
45° Indololwane 3.57 3.75 3.93 4.2 4.48 4.78 5.09 5.44 5.8
(1.088) (1.143) (1.198) (1.28) (1.366) (1.457) (1.551) (1.658) (1.768)
Ent. Ukulahlekelwa 9.27 9.73 10.21 10.89 11.62 12.39 13.22 14.11 15.05
(2.825) (2.966) (3.112) (3.319) (3.542) (3.776) (4.029) (4.301) (4.587)
 

 

10″ Umshini

 

I-Single Boiler

Ukusebenza okuqondile 0.28 0.28 0.29 0.3 0.31 0.32 0.32 0.33 0.34
(0.28) (0.28) (0.29) (0.30) (0.31) (0.32) (0.32) (0.33) (0.34)
90° Indololwane 1.6 1.68 1.77 1.88 2.01 2.14 2.29 2.44 2.6
(0.488) (0.512) (0.539) (0.573) (0.613) (0.652) (0.698) (0.744) (0.792)
45° Indololwane 1.21 1.27 1.33 1.42 1.51 1.61 1.72 1.84 1.96
(0.369) (0.387) (0.405) (0.433) (0.46) (0.491) (0.524) (0.561) (0.597)
Ent. Ukulahlekelwa 3.8 3.98 4.18 4.46 4.76 5.08 5.42 5.78 6.16
(1.158) (1.213) (1.274) (1.359) (1.451) (1.548) (1.652) (1.762) (1.878)
 

 

12″ Umshini

 

Ama-boilers amabili

Ukusebenza okuqondile 0.35 0.37 0.38 0.41 0.43 0.46 0.49 0.52 0.55
(0.35) (0.37) (0.38) (0.41) (0.43) (0.46) (0.49) (0.52) (0.55)
90° Indololwane 2.8 2.93 3.08 3.28 3.5 3.74 3.99 4.25 4.54
(0.853) (0.893) (0.939) (1) (1.067) (1.14) (1.216) (1.295) (1.384)
45° Indololwane 2.13 2.23 2.34 2.5 2.67 2.85 3.04 3.24 3.46
(0.649) (0.68) (0.713) (0.762) (0.814) (0.869) (0.927) (0.988) (1.055)
Ent. Ukulahlekelwa 7.33 7.69 8.07 8.6 9.18 9.79 10.45 11.15 11.89
(2.234) (2.344) (2.46) (2.621) (2.798) (2.984) (3.185) (3.399) (3.624)
 

 

14″ Umshini

 

Ama-boilers amabili

Ukusebenza okuqondile 0.16 0.17 0.18 0.19 0.2 0.21 0.23 0.24 0.25
(0.16) (0.17) (0.18) (0.19) (0.20) (0.21) (0.23) (0.24) (0.25)
90° Indololwane 1.45 1.53 1.6 1.71 1.82 1.94 2.07 2.21 2.36
(0.442) (0.466) (0.488) (0.521) (0.555) (0.591) (0.631) (0.674) (0.719)
45° Indololwane 1.12 1.18 1.24 1.32 1.41 1.5 1.6 1.71 1.83
(0.341) (0.36) (0.378) (0.402) (0.43) (0.457) (0.488) (0.521) (0.558)
Ent. Ukulahlekelwa 3.95 4.15 4.35 4.64 4.95 5.29 5.64 6.02 6.42
(1.204) (1.265) (1.326) (1.414) (1.509) (1.612) (1.719) (1.835) (1.957)
 

 

16″ Umshini

 

Ama-boilers amathathu

Ukusebenza okuqondile 0.18 0.19 0.19 0.21 0.22 0.23 0.25 0.27 0.28
(0.18) (0.19) (0.19) (0.21) (0.22) (0.23) (0.25) (0.27) (0.28)
90° Indololwane 1.90 1.99 2.09 2.23 2.38 2.54 2.71 2.89 3.08
(0.579) (0.607) (0.637) (0.68) (0.725) (0.774) (0.826) (0.881) (0.939)
45° Indololwane 1.49 1.56 1.64 1.74 1.86 1.99 2.12 2.26 2.41
(0.454) (0.475) (0.5) (0.53) (0.567) (0.607) (0.646) (0.689) (0.735)
Ent. Ukulahlekelwa 5.21 5.47 5.74 6.12 6.53 6.97 7.44 7.94 8.47
(1.588) (1.667) (1.75) (1.865) (1.99) (2.124) (2.268) (2.42) (2.582)
  Ngaphandle Kwezinga lokushisa Lomoya ngaphakathi °F (°C)
I-Inlet Duct & No Umbhobho Ingxenye Uhlobo -30 °F (-

34.4)

-15 °F (-

26.1)

0 °F

(-17.8)

20 °F

(-6.7)

40 °F

(4.4)

60 °F

(15.6)

80 °F

(26.7)

100 °F

(37.8)

120 °F

(48.9)

 

 

18″ Umshini

 

Ama-boilers amathathu

Ukusebenza okuqondile 0.10 0.10 0.11 0.11 0.12 0.13 0.14 0.15 0.16
(0.10) (0.10) (0.11) (0.11) (0.12) (0.13) (0.14) (0.15) (0.16)
90° Indololwane 1.16 1.22 1.28 1.37 1.46 1.56 1.66 1.77 1.89
(0.354) (0.372) (0.39) (0.418) (0.445) (0.475) (0.506) (0.539) (0.576)
45° Indololwane 0.92 0.96 1.01 1.08 1.15 1.23 1.31 1.4 1.49
(0.28) (0.293) (0.308) (0.329) (0.351) (0.375) (0.399) (0.427) (0.454)
Ent. Ukulahlekelwa 3.26 3.42 3.58 3.82 4.08 4.35 4.64 4.95 5.29
(0.994) (1.042) (1.091) (1.164) (1.244) (1.326) (1.414) (1.509) (1.612)
 

 

18″ Umshini

 

Ama-boilers amane

Ukusebenza okuqondile 0.17 0.18 0.19 0.2 0.21 0.22 0.24 0.25 0.27
(0.17) (0.18) (0.19) (0.20) (0.21) (0.22) (0.24) (0.25) (0.27)
90° Indololwane 2.07 2.17 2.28 2.43 2.59 2.77 2.95 3.15 3.36
(0.631) (0.661) (0.695) (0.741) (0.789) (0.844) (0.899) (0.96) (1.024)
45° Indololwane 1.63 1.71 1.80 1.92 2.04 2.18 2.33 2.48 2.65
(0.497) (0.521) (0.549) (0.585) (0.622) (0.664) (0.71) (0.756) (0.808)
Ent. Ukulahlekelwa 5.79 6.07 6.37 6.8 7.25 7.74 8.25 8.81 9.40
(1.765) (1.85) (1.942) (2.073) (2.21) (2.359) (2.515) (2.685) (2.865)
 

 

20″ Umshini

 

Ama-boilers amane

Ukusebenza okuqondile 0.10 0.11 0.11 0.12 0.12 0.13 0.14 0.15 0.16
(0.10) (0.11) (0.11) (0.12) (0.12) (0.13) (0.14) (0.15) (0.16)
90° Indololwane 1.3 1.37 1.44 1.53 1.63 1.74 1.86 1.98 2.12
(0.396) (0.418) (0.439) (0.466) (0.497) (0.53) (0.567) (0.604) (0.646)
45° Indololwane 1.03 1.08 1.13 1.21 1.29 1.37 1.46 1.56 1.67
(0.314) (0.329) (0.344) (0.369) (0.393) (0.418) (0.445) (0.475) (0.509)
Ent. Ukulahlekelwa 3.8 3.98 4.18 4.46 4.76 5.08 5.42 5.78 6.16
(1.158) (1.213) (1.274) (1.359) (1.451) (1.548) (1.652) (1.762) (1.878)

AMANOTHI:

  1. Ukubala kuthatha 700 SCFM (19.82 m3/min) kubhayela ngamunye ngenani eligcwele lomlilo
  2. Amayunithi amanani ehla ingcindezi ethi “Straight Run” ayizinyawo ezilinganayo ngonyawo ngalunye (eq. m / m)
  3. Amayunithi "ama-Elbows" kanye "ne-Ent. Ukulahlekelwa” amafidi alinganayo ngento ngayinye (eq. m / into)

Ukulungiswa Kwe-Air Altitude Kokushiswa

Ithebula Lokulungisa I-Altitude

Isayithi Ukuphakama Ngenhla Ulwandle Izinga I-Altitude Correction Factor (CF)
Izinyawo Amamitha  
0 0 1
500 152.4 0.982
1000 304.8 0.964
1500 457.2 0.947
2000 609.6 0.930
2500 762.0 0.913
3000 914.4 0.896
3500 1066.8 0.880
4000 1219.2 0.864
4500 1371.6 0.848
5000 1524.0 0.832
5500 1676.4 0.817
6000 1828.8 0.801
6500 1981.2 0.787
7000 2133.6 0.772
7500 2286.0 0.758
8000 2438.4 0.743
8500 2590.8 0.729
9000 2743.2 0.715
9500 2895.6 0.701
10000 3048.0 0.688

Umjikelezo vs Umbhobho ongunxande

Umbhobho Oyindilinga Wokucindezela Okufanayo Yehla uye Embotsheni Ewunxande

  • Ifomula: de = 1.3 (a × b)0.625 / (a ​​+ b)0.25

I-AERCO-TAG-0105B-Boiler-Pre-Install-Venting-and-Combustion-Air-Design-FIG (16)

Ngamayintshi

Eduze

Uhlangothi lwe-Duct ngamasentimitha

 

Uhlangothi Lombhobho ongunxande ngamayintshi

  6 8 10 12 14 16 18 20 22 24
6 6.6                  
8 7.6 8.7
10 8.4 9.8 10.9
12 9.1 10.7 12 13.1
14 9.8 11.5 12.9 14.2 15.3
16 10.4 12.2 13.7 15.1 16.4 17.5
18 11 12.9 14.5 16 17.3 18.5 19.7
20 11.5 13.5 15.2 16.8 18.2 19.5 20.7 21.9
22 12 14.1 15.9 17.6 19.1 20.4 21.7 22.9 24
24 12.4 14.6 16.5 18.3 19.9 21.3 22.7 23.9 25.1 26.2

Ngamasentimitha

Eduze Uhlangothi lwe-Duct ngo-cm  

Uhlangothi lwe-Rectangular Duct in Amasentimitha

  15.24 20.32 25.4 30.48 35.56 40.64 45.72 50.8 55.88 60.96
15.24 16.76                  
20.32 19.30 22.10
25.4 21.34 24.89 27.69
30.48 23.11 27.18 30.48 33.27
35.56 24.89 29.21 32.77 36.07 38.86
40.64 26.42 30.99 34.80 38.35 41.66 44.45
45.72 27.94 32.77 36.83 40.64 43.94 46.99 50.04
50.8 29.21 34.29 38.61 42.67 46.23 49.53 52.58 55.63
55.88 30.48 35.81 40.39 44.70 48.51 51.82 55.12 58.17 60.96
60.96 31.50 37.08 41.91 46.48 50.55 54.10 57.66 60.71 63.75 66.55

Ireferensi:

  1. I-National Fuel Gas Code, uhlelo lwango-2006, i-American National Standards Institute, Inc (ANSI Z223.1-2006) kanye ne-National Fire Protection Association (NFPA54-2006)

TAG-0105_B • 5/30/2024Technical Support • (800) 526-0288 • Mon-Fri, 8 am – 5 pm EST

Amadokhumenti / Izinsiza

PDF thumbnailTAG-0105B I-Boiler Ngaphambi Kokufaka Umhlahlandlela Wokuklama Umoya Wokuvula Nokushisa
User Guide · TAG-0105B, 5.29.24, TAG-0105B I-Boiler Ngaphambi kokufaka Umhlahlandlela Wokuklama Umoya Wokuvula Nokushisa, TAG-0105B, I-Boiler Ngaphambi Kokufaka Umhlahlandlela Wokuklama Umoya Wokuphuma Nokushisa, Faka Umhlahlandlela Wokuklama I-Venting and Combustion Air, Umhlahlandlela Womklamo Womoya Ovuthayo, Umhlahlandlela Womklamo Womoya, Umhlahlandlela Wokuklama, Umhlahlandlela

Izithenjwa

Buza Umbuzo

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Buza Umbuzo

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.