CISCO 8200 Series Catalyst Network Interface Module 0

Faka i-Cisco Catalyst Network Interface Module


Lesi sigaba sihlinzeka ngolwazi ngaphambi nangesikhathi sokufakwa kwe-Cisco Catalyst Network Interface Modules (NIMs) ku-Cisco Catalyst 8200 Series Edge Platforms.

Kuphelileview ye-Network Interface Module

The Cisco Catalyst Network Interface Module (NIM) is supported on Cisco Catalyst 8200 Series Edge Platforms.

These are the steps to install a NIM:

1. Thola i-NIM slot kuphaneli yangaphambili.
2. Loosen the screws to remove NIM blank cover.
3. Faka i-NIM esikhaleni.
4. Qinisa izikulufo ukuze uvikele i-NIM esikhaleni.

These are the steps to remove a NIM:

1. If the NIM is up and running, issue the following command to shut down the NIM gracefully before removing it:
hw-module subslot slot 0/2 stop

Isexwayiso
Isexwayiso
If you do not shut down the NIM gracefully before removing it, the NIM card could get damaged.

2. Thola i-NIM slot kuphaneli yangaphambili.
3. Khulula izikulufu ezivikela i-NIM.
4. Khipha ngobumnene i-NIM ku-slot.

All module slots must have a module or blank installed for the product to work thermally and for safety purposes.

Ukuze uthole imininingwane eyengeziwe, bheka imininingwane ye-Cisco Catalyst 8200 Series Edge Platforms ku-cisco.com ukuze uthole uhlu lwama-NIM asekelwayo ezinkundleni.

Susa futhi ufake amamojula e-Network Interface

Keep the following tools and equipment while working with the Network Interface Modules (NIM)s:

  • Inombolo 1 ye-screwdriver ye-Phillips noma i-screwdriver encane ene-flat-blade
  • Ibhande lesihlakala sesivikelo se-ESD
Susa i-Network Interface Module

Isinyathelo 1 Shut down the electrical power to the slot in the device, turn off the electrical power to the device. Leave the power cable plugged-in to channel ESD voltages phansi.
Isinyathelo 2 Remove all network cables from the rear panel of the device. Using a number 1 Phillips screwdriver, loosen the captive screws on the network interface module.
Isinyathelo 3 Slide the network interface module out.
Isinyathelo 4 If you are not replacing the module, install a blank faceplate over the empty slot to ensure proper air flow.

Faka amamojula we-Cisco Catalyst Network Interface

Isinyathelo 1 Shut down the electrical power to the slot in the router by turning off the electrical power to the router. Leave the power cable plugged in to channel ESD voltages phansi.
Isinyathelo 2 Remove all network cables from the rear panel of the device.
Isinyathelo 3 Remove the blank faceplates installed over the network interface module slot that you intend to use.

Qaphela
Qaphela Save blank faceplates for future use.
Isinyathelo 4 Align the module with the guides in the chassis walls or slot divider and slide it gently into the NIM slot on the device.
Isinyathelo 5 Push the module into place until you feel the edge connector seat securely into the connector on the router backplane. The module faceplate should contact the chassis rear panel.
Isinyathelo 6 Using a number 1 Phillips screwdriver, tighten the captive screws on the network interface module.
Isinyathelo 7 Connect the module to the network and re-enable the power to the slot in the device.

Faka i-Cisco Catalyst Network Interface Module

Amadokhumenti / Izinsiza

I-CISCO 8200 Series Catalyst Network Interface Module [pdf] Umhlahlandlela Womsebenzisi
8200 Series, 8200 Series Catalyst Network Interface Module, Catalyst Network Interface Module, Network Interface Module, Interface Module

Izithenjwa

Shiya amazwana