📘 DEEPELEC manuals • Free online PDFs
DEEPELEC logo

DEEPELEC Manuals & User Guides

DEEPELEC specializes in open-source based handheld vector network analyzers and high-sensitivity DSP radio receivers for electronics enthusiasts.

Tip: include the full model number printed on your DEEPELEC label for the best match.

About DEEPELEC manuals on Manuals.plus

I-DEEPELEC, operated by Hangzhou Minghong Electronic Technology Co., Ltd., designs and manufactures affordable radio frequency testing equipment and digital signal processing radios. The brand is widely known in the amateur radio community for its handheld Vector Network Analyzers (VNA), including the DeepVNA 101 and NanoVNA-F series, which provide portable antenna analysis capabilities.

Additionally, DEEPELEC produces multi-band DSP receivers like the DP-666, offering high sensitivity across FM, MW, SW, and LW bands. The company actively supports the open-source community, providing firmware updates and hardware based on popular open projects.

DEEPELEC manuals

Izincwadi zakamuva ezivela manuals+ ikhethelwe lolu hlobo.

DEEPELEC DeepVNA 101 Handheld Vector Network Analyzer Manual

Septhemba 24, 2022
DEEPELEC DeepVNA 101 Handheld Vector Network Analyzer User Manual www.deepelec.com Product introduction DeepVNA 101 "Handheld Vector Network Analyzer" is a product based on the NanoVNA open source project (https://ttrf.tk/kit/nanovna). We…

DEEPELEC NanoVNA-F Handheld Vector Network Analyzer Manual

Septhemba 6, 2022
DEEPELEC NanoVNA-F Handheld Vector Network Analyzer Product introduction NanoVNA-F "Handheld Vector Network Analyzer" is a product based on the Open Source Project of NanoVNA (https://ttrf.tk/kit/nanovna). We designed the NanoVNA-F hardware,…

DP-666 High Sensitivity Color Screen Radio Product Manual

Imanuwali Yomkhiqizo
Comprehensive product manual for the Deepelec DP-666 High Sensitivity Color Screen Radio, covering its advanced features, technical specifications, operation guide, interface explanations, menu navigation, charging instructions, and firmware upgrade procedures.

Векторный анализатор DEEPELEC NanoVNA-F: Инструкция по эксплуатации

Imaniwali yosebenzisayo
Полное руководство пользователя для ручного векторного анализатора цепей DEEPELEC NanoVNA-F, охватывающее введение в продукт, элементы управления, основные операции, калибровку, обновление прошивки и программное обеспечение для ПК.

I-NanoVNA: I-Guida Introduttiva e Versioni

Umkhiqizo Uphelileview / Umhlahlandlela
Esplora il NanoVNA, un analizzatore di rete vettoriale compatto. Questa guda fornisce una panoramica delle sue versioni, funzionalità e menu, conllegamenti utili per utenti amatoriali e professionisti.

DP-666 High Sensitivity Color Screen Radio User Manual

Imanuwali Yomkhiqizo
Comprehensive user manual for the Deepelec DP-666 High Sensitivity Color Screen Radio, detailing its features, specifications, operation, interface, menus, charging instructions, and firmware upgrade procedures.

I-NanoVNA-F Handheld Vector Network Analyzer Manual

imanuwali
Le manuwali ihlinzeka ngemiyalo kanye nemininingwane ye-NanoVNA-F Handheld Vector Network Analyzer, okuhlanganisa isingeniso somkhiqizo, ukusebenza okuyisisekelo, ukulinganisa, ukuthuthukiswa kwe-firmware, kanye nokusetshenziswa kwesofthiwe.

DEEPELEC manuals from online retailers

Malahit-DSP2 SDR Radio Receiver User Manual

DSP2 • December 7, 2025
Instruction manual for the Malahit-DSP2 SDR Radio, a high-sensitivity, wideband receiver with firmware 2.40, covering 10kHz-380MHz and 404MHz-2GHz. Includes setup, operation, specifications, and troubleshooting.

DP-666 TEF6686 Radio Instruction Manual

DP-666 • Okthoba 23, 2025
Comprehensive instruction manual for the DP-666 TEF6686 High Sensitivity Full Band FM AM LW MW SW Shortwave ESP32 RDS Radio with 2.8 inch IPS LCD, covering setup, operation,…

DEEPELEC support FAQ

Imibuzo evamile mayelana namamanyuwali, ukubhaliswa, nokusekelwa kwalolu mkhiqizo.

  • How do I calibrate my DEEPELEC VNA?

    Access the CAL menu and press RESET. Connect the OPEN, SHORT, and LOAD calibration standards to Port 1 sequentially, pressing the specific button on the screen for each step. Once complete, save the calibration data to one of the available save slots (0-4).

  • How do I update the firmware on the DeepVNA 101?

    Download the 'update.bin' file kusukela esikhulwini website. Connect the device to a PC via USB while holding the menu button to enter bootloader mode. The device will appear as a disk drive; copy the firmware file into this drive to update.

  • What should I do if my DEEPELEC radio speaker has no sound?

    If the speaker is silent but headphones work, the issue may be a stuck contact in the headphone jack. Try inserting and removing the headphone plug several times to release the internal pin spring mechanism.

  • Where can I download PC software for the NanoVNA-F?

    Official drivers and recommended PC software (such as NanoVNA-Saver) are linked on the DEEPELEC support page or the associated GitHub repositories.