GODIYMODULES Voltage Reference Module

GODIYMODULES Precision Voltage Reference Module User Manual

Imodeli: Voltage Reference Module

Isingeniso

The GODIYMODULES Precision Voltage Reference Module is designed for accurate voltage and resistance calibration. It features low-temperature drift components and is powered via a Type-C 5V port, eliminating the need for a battery. This module provides five distinct voltage reference levels and five resistance reference levels, making it suitable for verifying the accuracy and linearity of digital multimeters.

Umkhiqizo Uphelileview

GODIYMODULES Precision Voltage Reference Module, top-down view

Umfanekiso 1: i-Top Down view of the GODIYMODULES Precision Voltage Reference Module. This image shows the overall layout of the module, including the Type-C power input, DIP switches for selecting voltage, and output terminals.

The module incorporates an EMI filter for a cleaner power supply. It includes a green LED to indicate power status. The compact design (85x55x25mm) makes it convenient for various applications.

Isethaphu kanye Noxhumano

  1. Ukunikezwa kwamandla kagesi: Connect a 5V Type-C power source (0.5A minimum) to the Type-C port on the module. The green LED will illuminate to indicate power.
  2. Uxhumano Lokukhiphayo: Use appropriate test leads to connect your multimeter or device under test to the red (+) and black (-) output terminals on the module.
  3. Imvelo: For optimal accuracy, especially when verifying 4 1/2 digit multimeters, ensure the working environment maintains a stable temperature (16-30℃) and humidity (RH≤70%). Avoid direct airflow from air conditioners, which can introduce errors.
GODIYMODULES Precision Voltage Reference Module with Type-C port and DIP switches

Umfanekiso 2: Eduze view of the module showing the Type-C power input and the DIP switches for selecting reference values.

Imiyalelo yokusebenza

Ukukhetha Voltage Ireferensi

The module provides five voltage reference levels: 1.24V, 2.5V, 5V, 7.5V, and 10V. These are selected using the DIP switches labeled 1 to 5. Each switch corresponds to a specific voltagIzinga e.

  • Shintsha 1: 1.24V
  • Shintsha 2: 2.5V
  • Shintsha 3: 5V
  • Shintsha 4: 7.5V
  • Shintsha 5: 10V

Caution: Only one DIP switch for voltage selection should be in the "ON" position at any given time. Activating multiple voltage switches simultaneously is not permitted and may lead to incorrect readings or module damage.

Selecting Resistance Reference

The module provides five fixed resistance reference levels: 10Ω, 100Ω, 1KΩ, 10KΩ, and 100KΩ. These are available at dedicated terminals on the board. To measure a specific resistance, connect your multimeter to the corresponding resistance terminals.

GODIYMODULES Precision Voltage Reference Module showing resistance outputs

Umfanekiso 3: View of the module highlighting the fixed resistance output terminals (10R, 100R, 1K, 10K, 100K).

Usage for Multimeter Calibration

  • 3 1/2 Digit Multimeters: The module can be used to verify the accuracy and linearity of handheld 3 1/2 digit digital multimeters.
  • 4 1/2 Digit Multimeters: For 4 1/2 digit digital multimeters, it is crucial to maintain the same temperature and humidity conditions as specified in the multimeter's data sheet for accurate verification.

Isondlo

  • Ukuhlanza: Gcina imojuli ihlanzekile futhi ingenalo uthuli nemfucumfucu. Sebenzisa indwangu ethambile, eyomile ukuze uhlanze.
  • Isitoreji: Store the module in a dry environment, away from extreme temperatures and humidity.
  • Ukuphatha: Handle the module with care to avoid physical damage to components or connections.

Ukuxazulula inkinga

  • No Power Indication (Green LED Off):
    • Ensure the Type-C power cable is securely connected.
    • Verify that the 5V Type-C power source is functional and provides at least 0.5A.
  • IVolumu Engalungiletage lokukhipha:
    • Check that only one voltage selection DIP switch is in the "ON" position.
    • Ensure proper connection to the multimeter.
    • Verify environmental conditions (temperature, humidity) for sensitive measurements.
  • Ukufundwa Okungazinzile:
    • Operate in a low airflow environment to prevent temperature fluctuations.
    • Avoid direct cold wind from air conditioners.

Imininingwane

IsiciUkucaciswa
Igama LomkhiqizoVoltage Reference Module
IbhrendiGODIYMODULES
Ukunikezwa kwamandla kagesiType-C 5V port, 0.5A
Ukusetshenziswa kwamandla okungalayishi45mA
Inkomba YamandlaIsibani se-LED esiluhlaza
I-Reference Voltage Amazinga1.24V, 2.5V, 5V, 7.5V, 10V (5 levels)
Reference Resistance Levels10Ω, 100Ω, 1KΩ, 10KΩ, 100KΩ (5 levels)
Resistor Material0.1% Metal film copper feet & TCR: 25PPM
Dimensions (Clear Box Size)85mm x 55mm x 25mm
Isisindo sengqikithi34g
Indawo Yokusebenzela16-30℃, RH≤70%

Izinsiza Ezengeziwe

For a visual demonstration of a voltage reference module (note: this video may feature a similar but not identical product), please refer to the video below:

Ifilimu 1: Demonstration of a Voltage Reference Module. This video provides a general overview of how a voltage reference module might be used, including handling and basic operation. While the module shown may differ slightly from the GODIYMODULES model, it illustrates the general principles of such devices.

Iwaranti kanye Nokusekela

Specific warranty information for the GODIYMODULES Precision Voltage Reference Module is not provided in the product details. For warranty claims or technical support, please contact your retailer or the manufacturer directly.

© 2024 GODIYMODULES. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.