1. Isingeniso
The REDPINGUO Temp-01 Digital Temperature Controller Thermostat is an advanced, easy-to-use device designed to precisely control temperature for a wide range of applications. It features both heating and cooling modes, along with versatile timing functions, making it suitable for environments requiring stable temperature regulation such as homebrewing, greenhouses, terrariums, incubators, and more.
2. Izici zomkhiqizo
- I-Smart Thermostat: Features Heating & Cooling modes with a 1.7m NTC 10K temperature sensor probe. Automatically activates or deactivates connected devices based on your preset target temperatures, ensuring consistent comfort and energy efficiency.
- Ukufaka nokusebenza okulula: A plug-and-play unit requiring no complex installation or wiring. Simply plug it into a standard 110V AC outlet.
- Ibanga Lokushisa Elibanzi: Controls temperatures from -40℃ to 120℃ (-40℉ to 248℉) with an accuracy of ±1℃.
- Dual Display Units: Allows selection between Celsius (℃) or Fahrenheit (℉) temperature display on the LCD.
- Advanced Timing Functions: Includes F01 Cycle Timer mode, F02 Countdown ON mode, F03 Countdown OFF mode, and F04 Countdown ON and Countdown OFF mode. Timing range is 0 to 99 hours and 59 minutes.
- Uhlelo lokusebenza olubanzi: Suitable for various uses including greenhouses, reptile habitats, incubators, terrariums, freezers, refrigerators, heaters, and homebrew setups.
- Ukulinganisa Izinga lokushisa: Allows for fine-tuning of temperature readings to ensure accuracy.
- Ukuvikela Ukukhiya isikrini: Ivimbela izinguquko zephutha kuzilungiselelo.
- Umsebenzi Wenkumbulo: All current settings are automatically saved and retained even after a power outage.
- Ukusetha kabusha kwefekthri: Option to restore the device to its original factory settings.
3. Okuqukethwe Kwephakheji
- 1 x REDPINGUO Digital Temperature Controller Thermostat (Model: Temp-01) with integrated 1.7m NTC 10K Sensor
4. Umkhiqizo Uphelileview
The REDPINGUO Temp-01 thermostat features a clear LCD display, intuitive control buttons, a built-in power outlet, and a wired temperature sensor probe.

Umfanekiso 1: Ngaphambili view of the thermostat with its display and integrated power outlet.

Figure 2: Close-up of the control panel, highlighting the display and buttons.

Umfanekiso 3: Ngemuva view of the thermostat, displaying product information and the power plug.
5. Setha
- Khipha: Carefully remove the thermostat from its packaging.
- Xhuma: Insert the thermostat's plug into a standard 110V AC power outlet. The LCD display will illuminate.
- Inzwa yendawo: Place the 1.7m temperature sensor probe in the area where you wish to monitor and control the temperature. Ensure the probe is not directly exposed to heat sources or extreme cold that could skew readings.
- Xhuma Idivayisi: Plug your heating or cooling appliance into the power outlet on the front of the thermostat.

Figure 4: The thermostat unit plugged into a power source, ready for use.
6. Iziqondiso Zokusebenza
The thermostat offers both temperature control and various timing functions. Use the 'MODE', 'SET', 'UP', and 'DOWN' buttons to navigate and adjust settings.
6.1. Temperature Control Mode
- View Izinga lokushisa lamanje: The top line of the LCD displays the 'Measured Temperature'.
- Set Start Temperature (ON): Press the 'SET' button once. The 'Start Temperature' value will flash. Use 'UP' or 'DOWN' buttons to adjust the desired temperature for the device to turn ON. Press 'SET' again to confirm.
- Set Stop Temperature (OFF): After setting the Start Temperature, press 'SET' again. The 'Stop Temperature' value will flash. Use 'UP' or 'DOWN' buttons to adjust the desired temperature for the device to turn OFF. Press 'SET' again to confirm and exit setting mode.
- Imodi yokushisisa: If the 'Start Temperature' is set lower than the 'Stop Temperature', the thermostat operates in heating mode. The connected device will turn on when the measured temperature drops below the Start Temperature and turn off when it reaches the Stop Temperature.
- Imodi Yokupholisa: If the 'Start Temperature' is set higher than the 'Stop Temperature', the thermostat operates in cooling mode. The connected device will turn on when the measured temperature rises above the Start Temperature and turn off when it drops to the Stop Temperature.
- Switch ℃/℉: Press and hold the 'UP' button for 3 seconds to toggle between Celsius (℃) and Fahrenheit (℉).
6.2. Timing Functions
Press the 'MODE' button repeatedly to cycle through the different timing modes (F01, F02, F03, F04) and the temperature control display.

Umdwebo 5: Ngaphezuluview of the timing function displays and their corresponding modes.
- F01: Cycle Timer Mode
In this mode, you set an ON duration and an OFF duration for the connected device to cycle repeatedly. Press 'SET' to enter editing, use 'UP'/'DOWN' to adjust hours/minutes for ON time, then press 'SET' to move to OFF time, adjust, and press 'SET' again to confirm. - F02: Countdown ON Mode
The device will turn ON after a set countdown period. Press 'SET' to enter editing, use 'UP'/'DOWN' to set the countdown hours/minutes, then press 'SET' to confirm. - F03: Countdown OFF Mode
The device will turn OFF after a set countdown period. Press 'SET' to enter editing, use 'UP'/'DOWN' to set the countdown hours/minutes, then press 'SET' to confirm. - F04: Countdown ON and Countdown OFF Mode
This mode combines F02 and F03. You set a countdown for the device to turn ON, and then a separate countdown for it to turn OFF. Press 'SET' to enter editing, set the ON countdown, press 'SET', then set the OFF countdown, and press 'SET' again to confirm.
6.3. Ukulinganisa izinga lokushisa
If the measured temperature is inaccurate, you can calibrate the sensor. Press and hold the 'SET' button for 3 seconds to enter the calibration menu. Use 'UP' or 'DOWN' to adjust the offset value (e.g., +0.5℃ or -0.5℉). Press 'SET' to save and exit.
6.4. Screen Lock Protection
To prevent accidental changes, the screen can be locked. Press and hold the 'MODE' button for 3 seconds to lock or unlock the screen. A lock icon may appear on the display when locked.
6.5. Umsebenzi Wememori
The thermostat is equipped with a memory function. All your configured settings (temperature and timing modes) will be automatically saved and restored in case of a power interruption.
6.6. Ukusetha kabusha kwasefekthri
To restore the thermostat to its original factory settings, press and hold the 'DOWN' button for 3 seconds. Confirm the reset if prompted.
Video: A demonstration of the REDPINGUO Digital Temperature Controller's features and operation, including button presses and display changes.
7. Isondlo
- Ukuhlanza: Wipe the unit with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water.
- Ukunakekelwa Kwezinzwa: Ensure the temperature sensor probe is kept clean and free from debris for accurate readings. Avoid bending or damaging the sensor cable.
- Isitoreji: When not in use for extended periods, store the thermostat in a cool, dry place away from direct sunlight and extreme temperatures.
8. Ukuxazulula izinkinga
- Isibonisi Asisebenzi: Ensure the unit is properly plugged into a live 110V AC outlet. Check the power source.
- Ukufundwa Kwezinga Lokushisa Okungalungile: Verify the temperature sensor probe is correctly positioned and not damaged. Perform a temperature calibration (refer to Section 6.3).
- Device Not Turning ON/OFF: Check that the Start and Stop temperatures are set correctly for either heating or cooling mode. Ensure the connected appliance is functioning properly and is plugged securely into the thermostat's outlet.
- Izilungiselelo Azilondolozi: The unit has a memory function. If settings are not retained, ensure the unit is not being subjected to extreme electrical fluctuations.
9. Imininingwane
| Ukucaciswa | Inani |
|---|---|
| Inombolo Yemodeli | I-Temp-01 |
| Ukunikezwa kwamandla kagesi | AC 110V ±15% 50Hz |
| Ubukhulu. Layisha | 15A / 110V (Max 1800W) |
| Ibanga lokulawula izinga lokushisa | -40 ℃ kuye ku-120 ℃ (-40 ℉ kuye ku-248 ℉) |
| Lawula Ukunemba | ±1℃ |
| Uhlobo lwenzwa | 1.7m NTC10K/B3950 |
| Ukunemba Kwesikhathi | MAX 10 amaminithi |
| I-Ambient Temperature | -20 ℃ kuye ku-60 ℃ (-4 ℉ kuye ku-140 ℉) |
| Uhlobo lokubonisa | I-LED |
| Ubukhulu bomkhiqizo | 2.28 x 1.53 x 4.72 amayintshi |
| Isisindo sento | 6.4 amakhilogremu |
| Okubalulekile | I-Acrylonitrile Butadiene Styrene (ABS) |
| Izwe azalelwe kulo | China |
10. Iwaranti kanye Nokusekela
For warranty information, technical support, or service inquiries, please refer to the documentation included with your product packaging or visit the official REDPINGUO webindawo. Gcina irisidi yakho yokuthenga ukuze uthole izimangalo zewaranti.