JIAYIN JYPC-4

JIAYIN JYPC-4 Series Electromagnetic Plunger Pump User Manual

Model: JYPC-4

1. Isingeniso

This manual provides essential information for the safe and effective installation, operation, and maintenance of the JIAYIN JYPC-4 Series Electromagnetic Plunger Pump. This pump is designed for applications requiring precise water suction and delivery, commonly found in hot water dispensers and similar systems. Please read this manual thoroughly before using the product and retain it for future reference.

2. Umkhiqizo Uphelileview

The JIAYIN JYPC-4 is a compact and efficient electromagnetic plunger pump. Key features include:

  • Kulinganiswe ngoVoltage: AC 100V - 120V, 60Hz, 22W
  • Isilinganiso sokugeleza: 750 ±15% cc/min
  • Ingcindezi Yokusebenza: ≥1.5 bar
  • Indawo yokusebenza: Water or non-corrosive liquids
  • Okubalulekile: Ukwakhiwa kwepulasitiki okuhlala isikhathi eside
  • Imodi yeDrayivu: I-electromagnetic
JIAYIN JYPC-4 Series electromagnetic plunger pump, angled view

Umfanekiso 1: I-engeli view of the JIAYIN JYPC-4 Series electromagnetic plunger pump, showing its compact design and main components.

JIAYIN JYPC-4 pump showing electrical terminals and product label

Umfanekiso 2: Vala-up view of the JIAYIN JYPC-4 pump, highlighting the electrical terminals and the product specification label.

Technical drawing with dimensions of the JIAYIN JYPC-4 pump

Figure 3: Technical drawing providing detailed dimensions of the JIAYIN JYPC-4 pump in millimeters.

3. Imininingwane Yezobuchwepheshe

IpharamithaInani
IbhrendiJIAYIN
ImodeliJYPC-4
Kulinganiswe ngoVoltageAC 100V - 120V, 60Hz
Ukusetshenziswa kwamandla22W
Isilinganiso sokugeleza750 ±15% cc/min
Ingcindezi Yokusebenza≥1.5 bar
Uhlobo LwephampuIphampu ye-Plunger
Pump Shaft PositionEvundlile
Impeller StructureClosed Impeller
Number of ImpellersOngashadile Stage
Isisindo sengqikithi137 ±5g (approx. 4.8 oz)
OkubalulekileIpulasitiki
I-Insulation ClassH
Imodi yeDrayivuI-electromagnetic
Indlela YokuxhumaICannula
I-Ambient TemperatureTa 70℃ (158°F)
Fluid TemperatureTf 60℃ (140°F)
I-UPC607469294553

4. Iziyalezo Zokuphepha

Ukuze uvimbele ukulimala noma ukulimala, hlala uqaphela lezi zinyathelo zokuphepha ezilandelayo:

  • Ukuphepha Kagesi: Qinisekisa ukuthi iphampu ixhunywe emthonjeni wamandla ohambisana nevolumu echaziwetage (AC 100V-120V, 60Hz). Disconnect power before any installation, maintenance, or troubleshooting.
  • Ukuhambelana kwe-Fluid: Use only with water or non-corrosive liquids. Using corrosive fluids can damage the pump and void the warranty.
  • Imikhawulo Yezinga lokushisa: Do not exceed the maximum ambient temperature of 70℃ (158°F) or fluid temperature of 60℃ (140°F).
  • Ukufaka Okufanelekile: Install the pump securely in a horizontal position as specified. Ensure all connections are tight to prevent leaks.
  • Gwema Ukugijima Komile: Do not operate the pump without fluid, as this can cause severe damage.
  • Ukungenisa umoya: Ensure adequate ventilation around the pump to prevent overheating.
  • Izingane Nezilwane ezifuywayo: Keep the pump and its components out of reach of children and pets.

5. Ukusetha nokufakwa

Landela lezi zinyathelo ukuze ufake kahle:

  1. Ukukhweza: Securely mount the pump in a horizontal position using appropriate fasteners. Refer to Figure 3 for dimensions and mounting points.
  2. Ukuxhumana Kwamanzi: Connect the inlet and outlet tubes to the pump's cannula ports. Ensure a tight fit to prevent leaks. For flow testing, a 13.8-inch silicon tube with an outer diameter of 0.31 inches and an inner diameter of 0.16 inches is recommended for the water inlet port.
  3. Uxhumano lukagesi: Connect the pump to a compatible AC 100V-120V, 60Hz power supply. Ensure wiring is done by a qualified professional if you are unsure.
  4. Ukuhlanza (uma kudingeka): Depending on your system, you may need to prime the pump by ensuring the fluid path is filled with liquid before initial operation to prevent dry running.

6. Ukusebenza

Once installed and connected, operate the pump as follows:

  1. Vula: Apply power to the pump. The electromagnetic mechanism will activate, initiating the plunger action.
  2. Gada Ukugeleza: Observe the fluid flow to ensure it is within the specified range of 750 ±15% cc/min and that the working pressure is maintained at or above 1.5 bar.
  3. Ukusebenza okuqhubekayo: The pump is designed for continuous operation (ED100%).
  4. Cisha ugesi: Disconnect power when the pump is not in use or when maintenance is required.

7. Isondlo

Regular maintenance ensures optimal performance and extends the pump's lifespan:

  • Ukuhlanza: Periodically inspect the pump for any external dirt or debris. Clean with a soft, damp indwangu. Ungasebenzisi amakhemikhali anokhahlo.
  • Izixhumanisi: Regularly check all fluid and electrical connections for tightness and signs of wear or corrosion.
  • Ikhwalithi Yoketshezi: Ensure the working fluid remains clean and free of particles that could clog the pump. If the fluid contains impurities, consider adding a filter to the system.
  • Isitoreji: If storing the pump for an extended period, ensure it is clean, dry, and stored in a cool, dry place away from direct sunlight and extreme temperatures.

8. Ukuxazulula izinkinga

Bheka ithebula elingezansi ngezinkinga ezivamile nezisombululo zazo ezingaba khona:

InkingaImbangela EngenzekaIsixazululo
Ipompo ayiqaliAkukho ukunikezwa kwamandla
Ivolumu engalungiletage
Uxhumano lukagesi oluxegayo
Hlola umthombo wamandla
Qinisekisa ivolumutage matches pump rating
Vikela ukuxhumana kukagesi
Low or no fluid flowInlet/outlet clogged
Air in the system (not primed)
Leak in fluid connections
Ukugijima okomile
Inspect and clear blockages
Iphampu yokuqala
Hlola futhi uqinise ukuxhumana
Ensure fluid supply is constant
Umsindo ongajwayelekile ngesikhathi sokusebenzaUmoya ohlelweni
Ukukhweza okuxekethile
Ukuvinjwa kwangaphakathi
Wopha umoya ohlelweni
Qinisa izikulufu ezifakwayo
Inspect for foreign objects (disconnect power first)
Ukuvuza kokuxhumanaUkuxhumana okuxekethile
Damaged tubing/cannula
Tighten all fluid connections
Replace damaged tubing or cannula

9. Iwaranti kanye Nokusekela

For warranty information or technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase. Any unauthorized disassembly or modification of the pump will void the warranty.

© 2025 JIAYIN. All rights reserved.

Ask a question about this manual