JIAYIN JYPC-3

JIAYIN JYPC-3 Series Electromagnetic Plunger Pump User Manual

Model: JYPC-3

1. Isingeniso

This manual provides essential information for the safe and effective use of your JIAYIN JYPC-3 Series Electromagnetic Plunger Pump. Please read these instructions thoroughly before installation, operation, or maintenance to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2. Umkhiqizo Uphelileview

The JIAYIN JYPC-3 is an original plunger-type electromagnetic pump designed for various applications, including hot water dispensers. It operates on AC 110V-120V power, delivering a flow rate of 700cc/min with a working pressure up to 2.5 bar. Its robust design ensures reliable performance with water or non-corrosive liquids.

Izici Eziyinhloko:

  • Designed for AC 110V-120V, 60Hz power supply.
  • 25W power consumption.
  • Flow rate of 700 ±10% cc/min.
  • Suitable for water or non-corrosive liquids.
  • Operating ambient temperature: up to 70℃ (158°F).
  • Operating medium temperature: up to 60℃ (140°F).
  • Plunger type mechanism for efficient suction.
JIAYIN JYPC-3 Electromagnetic Plunger Pump

Umfanekiso 2.1: Ngaphambili view of the JIAYIN JYPC-3 electromagnetic plunger pump, showing the main body, electrical terminals, and inlet/outlet ports.

JIAYIN JYPC-3 Pump Angled View

Umfanekiso 2.2: I-engeli view of the JIAYIN JYPC-3 pump, highlighting the plunger mechanism and compact design.

3. Imininingwane Yezobuchwepheshe

The following table details the technical specifications of the JIAYIN JYPC-3 electromagnetic plunger pump:

IpharamithaInani
ImodeliJYPC-3
IbhrendiJIAYIN
UhloboElectromagnetic Plunger Pump
VoltageI-AC 110V-120V
Imvamisa60Hz
Amandla25W
Isilinganiso sokugeleza700 ±10% cc/min
Ingcindezi Yokusebenza0-2.5 ibha
Working MediumWater or non-corrosive liquid
I-Ambient TemperatureUp to 70℃ (158°F)
Izinga Lokushisa EliphakathiUp to 60℃ (140°F)
Pump Shaft PositionEvundlile
Isisindo sengqikithi137 ±5g (approx. 5.2 ounces)
Ubukhulu bomkhiqizoCishe. 3.84 x 1.5 x 1.5 amayintshi (97.5 x 38 x 38 mm)
OkubalulekileIpulasitiki
JIAYIN JYPC-3 Pump Dimensions Diagram

Figure 3.1: Detailed dimensional drawing of the JIAYIN JYPC-3 pump, showing key measurements in millimeters and inches.

JIAYIN JYPC-3 Technical Parameters and Performance Graphs

Figure 3.2: Technical parameters and performance graphs for the JIAYIN JYPC-3 pump, illustrating flow/pressure, flow time, and temperature/time relationships.

4. Ulwazi Lokuphepha

Adhering to safety precautions is crucial for preventing injury and damage to the pump. Please observe the following:

  • Ukuphepha Kagesi: Qinisekisa ukuthi ukunikezwa kwamandla kufana nevolumu yephamputage (AC 110V-120V). Disconnect power before installation, maintenance, or troubleshooting. All electrical connections should be performed by a qualified individual and comply with local electrical codes.
  • Ukuhambisana Koketshezi: Use only water or non-corrosive liquids. Using corrosive chemicals can damage the pump and void the warranty.
  • Imikhawulo Yezinga lokushisa: Do not exceed the specified ambient (70℃/158°F) or medium (60℃/140°F) temperature limits. Overheating can lead to pump failure.
  • Ukufaka Okufanelekile: Install the pump in a horizontal position as specified. Incorrect orientation may affect performance and longevity.
  • Gwema Ukugijima Komile: Do not operate the pump without liquid. Dry running can cause severe damage to internal components.
  • Vikela Ukuxhumana: Ensure all tubing and electrical connections are secure to prevent leaks or electrical hazards.
  • Izingane Nezilwane ezifuywayo: Keep the pump and its associated components out of reach of children and pets.

5. Ukusetha nokufakwa

Follow these steps for proper installation of your JYPC-3 pump:

  1. Ukukhulula: Carefully remove the pump from its packaging. Inspect for any visible damage.
  2. Ukukhweza: Mount the pump securely in a horizontal position. Ensure there is adequate space for tubing connections and ventilation.
  3. Izixhumanisi ze-Tubing:
    • Connect the inlet tubing to the designated inlet port. The product description specifies a flow test method using a 13.8-inch silicon tube with an outer diameter of 0.31 inches and an inner diameter of 0.16 inches. Ensure your tubing is compatible and securely fastened to prevent leaks.
    • Connect the outlet tubing to the designated outlet port.
    • Ensure tubing is not kinked or obstructed.
  4. Izixhumanisi zikagesi:
    • Ensure the power source is disconnected before making any electrical connections.
    • Connect the pump's electrical terminals to an AC 110V-120V, 60Hz power supply. Refer to the wiring diagram of your specific application for correct polarity if applicable.
    • Verify all electrical connections are tight and insulated to prevent short circuits or electrical hazards.
  5. Ukuhlanza (uma kudingeka): Depending on your application, the pump may require priming to ensure it is filled with liquid before initial operation. Consult your system's specific requirements.
JIAYIN JYPC-3 Pump with Electrical Terminals

Umfanekiso 5.1: View of the JIAYIN JYPC-3 pump showing the electrical terminals for power connection.

JIAYIN JYPC-3 Pump with Red Port Caps

Figure 5.2: The JIAYIN JYPC-3 pump with protective red caps on the inlet and outlet ports, indicating proper handling before tubing installation.

6. Iziqondiso Zokusebenza

Once the pump is properly installed and all connections are secure, you can begin operation:

  1. Verify Liquid Supply: Ensure there is an adequate supply of the intended liquid (water or non-corrosive) available at the pump's inlet. Never operate the pump dry.
  2. Vula: Connect the pump to the AC 110V-120V, 60Hz power supply. The pump should begin to operate, drawing liquid through the inlet and expelling it through the outlet.
  3. Gada ukusebenza: Observe the pump during initial operation. Check for any unusual noises, vibrations, or leaks. Verify that liquid is flowing as expected.
  4. Ukulawula Ukugeleza: The pump has a flow control range of ±10%. If your system requires precise flow, integrate appropriate external flow control mechanisms.
  5. Cisha ugesi: To stop the pump, disconnect it from the power supply.

7. Isondlo

Regular maintenance helps ensure the longevity and optimal performance of your JYPC-3 pump:

  • Ukuhlola Okuvamile: Periodically inspect the pump and all connections for signs of wear, damage, or leaks.
  • Inhlanzeko: Ensure the pump's exterior is kept clean. Prevent dust and debris from accumulating around the motor housing, which could impede cooling.
  • Vimbela Ukuvaleka: If the pump is used with liquids that may contain particulates, consider installing an inline filter on the inlet side to prevent clogging of the pump''s internal mechanisms.
  • Isitoreji: If the pump is to be stored for an extended period, drain any remaining liquid and store it in a dry, clean environment.
  • Azikho Izingxenye Ezingasetshenziswa Umsebenzisi: The internal components of the pump are not designed for user servicing. Do not attempt to disassemble the pump, as this may cause damage and void the warranty.

8. Ukuxazulula izinkinga

If you encounter issues with your JYPC-3 pump, refer to the following troubleshooting guide:

InkingaImbangela EngenzekaIsixazululo
Ipompo ayiqaliAkukho ukunikezwa kwamandla
Ivolumu engalungiletage
Ukuxega kukagesi
Hlola indawo kagesi kanye ne-circuit breaker
Verify power supply is AC 110V-120V
Vikela konke ukuxhumana kukagesi
Pump runs but no liquid flowsNo liquid in supply
Inlet tubing kinked or blocked
Pump not primed (airlock)
Ukuvinjelwa kwangaphakathi
Ensure liquid supply is available
Inspect and clear inlet tubing
Prime the pump according to system requirements
Check for foreign objects (if accessible without disassembly)
Izinga lokugeleza elincishisiwePartial blockage in tubing or pump
Air leak in inlet line
Worn components (after extended use)
Inspect and clear tubing/inlet
Tighten all inlet connections
Consider pump replacement if wear is suspected
Umsindo ongajwayelekile noma ukudlidlizaUkugijima okomile
Ukukhweza okuxekethile
Internal obstruction or damage
Ensure continuous liquid supply
Qinisa izikulufu ezifakwayo
If noise persists, discontinue use and contact support
Liquid leaksLoose tubing connections
Damaged tubing or pump housing
Tighten all tubing connections
Inspect tubing and pump for cracks; replace damaged components

Uma inkinga iqhubeka ngemva kokuzama lezi zixazululo, sicela uxhumane nokwesekwa kwamakhasimende.

9. Iwaranti kanye Nokwesekwa Kwekhasimende

For warranty information or technical assistance, please contact the retailer or manufacturer directly. Provide your product model (JYPC-3) and purchase date when seeking support. Do not attempt to repair the pump yourself, as this may void any applicable warranty.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.