Isingeniso
This instruction manual provides essential information for the safe and effective installation of the Romalon WP3387747 Dryer Heating Element Replacement Kit. This kit includes a heating element, a thermal fuse, and a thermostat kit, designed to restore heating functionality to compatible dryers. Please read all instructions carefully before beginning any repair work.
Ulwazi Lokuphepha Olubalulekile
Failure to follow these safety instructions could result in fire, electric shock, serious injury, or death. Always prioritize safety during appliance repair.
- Nqamula Amandla: Always disconnect the dryer from its power source (unplug or turn off circuit breaker) before attempting any service or repair.
- Gqoka Igiya Lokuzivikela: Wear work gloves to protect your hands from sharp edges and potential heat. Safety glasses are also recommended.
- Usizo Lochwepheshe: If you are unsure about any step or uncomfortable performing the repair, consult a qualified appliance technician.
- Amathuluzi Afanelekile: Use appropriate tools for the job to prevent damage to the appliance or injury.
- Ukungenisa umoya: Qinisekisa ukuthi indawo yokusebenza inomoya omuhle.
- Original Housing: The heating element is supplied without a housing. You must reuse the original dryer housing for proper installation.

Ukuphepha Kuqala: Always disconnect power and wear protective gloves before servicing your dryer. This image illustrates the importance of safety precautions and shows the kit components.
Okuqukethwe Kwephakheji
The Romalon WP3387747 Dryer Heating Element Replacement Kit includes the following components:
- 1 x 3387747 Dryer Heating Element Assembly
- 1 x 279816 Dryer Thermostat Kit (includes 3977393 thermal cut-off and 3390291 hi-limit thermostat)
- 2 x 3392519 Dryer Thermal Fuses

Izingxenye zekhithi: This image displays the complete 4-piece repair kit, including the heating element, thermostat kit, and thermal fuses.
Umkhiqizo Uphelileview
Understanding the function of each component is crucial for proper installation and troubleshooting.
3387747 Dryer Heating Element
This component is responsible for generating the heat required to dry clothes. It consists of a coiled wire that heats up when electricity passes through it. Qaphela: This heating element is supplied without a housing; you must reuse your dryer's existing housing.

Isici Sokushisa: A enemininingwane view of the 3387747 dryer heating element assembly, which generates heat for drying.
3392519 Dryer Thermal Fuse
The thermal fuse is a safety device designed to cut off power to the dryer if it overheats, preventing potential fire hazards. It is a non-resettable component and must be replaced if it blows.
279816 Dryer Thermostat Kit
This kit includes a thermal cut-off (3977393) and a hi-limit thermostat (3390291). The hi-limit thermostat monitors and regulates the dryer's temperature, while the thermal cut-off acts as a secondary safety measure, preventing overheating if the primary thermostat fails.

Replacement Parts Overview: This image illustrates the individual components of the kit, including the heating element, thermal fuse, and thermostat kit, along with their part numbers.
Amamodeli Omshini Wokomisa Ahambisanayo
This replacement kit is compatible with a wide range of dryer models from various brands. Please verify your dryer's model number against the list below or consult your appliance's service manual to ensure compatibility.

Ukuhambisana Kwemodeli: This image provides a list of various dryer models from brands like Whirlpool, Maytag, and Kenmore that are compatible with the WP3387747 heating element.
Partial List of Compatible Models:
- I-Whirlpool: GEW9250PL0, YGEW9200LW0, YGEW9200LW2, YCEE2760KQ0, YCEE2760KQ1, YCEE2760KQ2, YCEE2790KQ1, etc.
- Meyitag: 7MMEDX550XW0, 7MMEDX550XW1, MEDP475EW0, YMED9600SQ0, YMED9700SB0, YMED9700SQ0, etc.
- UKenmore: 36396593200, 36396593400, 11066952690, 11068132414, 11068133414, 11069132414, 11069133414, etc.
- KitchenAid: KHEV01RSS0, YKEHS01PMT0, YKEHS01PMT1, YKEHS01PMT2, etc.
- Amana: 4KAED4900BW0, 4KAED4900BW1, 4KMEDC100BQ0, 4KNED4400BQ0, 4KNED4400BQ1, etc.
- I-Sears: 110C85081400, 110C85088400, 110C85089400, etc.
- Inglis: YIED5900HW0, YIED5900HW2, YIED7300WW0, etc.
- UCrosley: CED7464GW1, etc.
If your specific model is not listed, you can contact Romalon customer support with your dryer model number for assistance in verifying compatibility.
Imiyalelo yokufaka
This section provides general steps for replacing the dryer heating element and associated components. Specific disassembly and reassembly procedures may vary by dryer model. Always refer to your dryer's service manual or a reputable online repair guide for detailed, model-specific instructions.
- Nqamula Amandla: Crucially, unplug the dryer from the electrical outlet or turn off the circuit breaker supplying power to the dryer. Verify power is off before proceeding.
- Access the Heating Element: Depending on your dryer model, you may need to remove the front panel, back panel, or both to access the heating element assembly. This often involves removing screws and disconnecting wire harnesses.
- Ukuxhumana Kwedokhumenti: Before disconnecting any wires, take photos or make notes of how all wires are connected to the heating element, thermal fuse, and thermostat. This will aid in correct reassembly.
- Susa Izingxenye Ezindala: Carefully disconnect the wires and mounting screws holding the old heating element assembly, thermal fuse, and thermostat in place. Remove these components from the dryer.
- Transfer Housing (if applicable): If your new heating element did not come with a housing, carefully transfer the new heating element coil into your dryer's original housing. Ensure it is seated correctly.
- Faka Izingxenye Ezintsha: Install the new 3387747 heating element assembly, 3392519 thermal fuses, and 279816 thermostat kit into their respective positions. Secure them with the appropriate screws.
- Xhuma kabusha izintambo: Using your documented connections, carefully reattach all wires to the new components. Ensure all connections are secure and properly insulated.
- Hlanganisa kabusha umshini wokomisa: Reattach any panels or covers that were removed during disassembly. Ensure all screws are tightened and the dryer is fully reassembled.
- Ukusebenza Kokuhlola: Plug the dryer back into the electrical outlet or restore power at the circuit breaker. Run a short cycle with a damp load to verify that the dryer heats properly and operates without issues. Monitor for any unusual smells or sounds during the initial test.
If the dryer does not heat or exhibits other problems after installation, refer to the Troubleshooting section or contact a qualified technician.
Ukuxazulula Izinkinga Ezivamile
If your dryer is not functioning correctly after replacing the components, consider the following common issues:
- Umshini Wokomisa Awufudumezi:
- Ensure the dryer is receiving full power (240V for electric dryers).
- Check if the thermal fuse (3392519) has blown again. This often indicates an underlying issue like poor ventilation or a faulty thermostat.
- Verify the thermostat kit (279816) is functioning correctly. A faulty hi-limit thermostat can prevent heating.
- Inspect all wire connections to ensure they are secure and not loose or corroded.
- Dryer Overheating:
- Check for blocked dryer vents. Restricted airflow is a primary cause of overheating and can cause thermal fuses to blow. Clean the lint trap and the entire exhaust duct system.
- Ensure the thermostat kit (279816) is installed correctly and functioning. A stuck thermostat can lead to continuous heating.
- Dryer Runs but Does Not Dry Clothes Effectively:
- Confirm the heating element (3387747) is glowing and producing heat.
- Check for proper airflow. A clogged lint screen or exhaust vent can significantly reduce drying efficiency.
For persistent issues, it is recommended to consult a professional appliance repair technician.
Imininingwane
| Isakhi | Incazelo |
|---|---|
| Isici Sokushisa | WP3387747 (5400 Watts, 240 Volts) |
| Fuse Thermal | 3392519 (Ubuningi: 2) |
| Ikhithi ye-Thermostat | 279816 (Includes 3977393 thermal cut-off and 3390291 hi-limit thermostat) |
| Isisindo sento | Cishe amakhilogremu angu-1.21 |
| Ubukhulu bephakheji | Cishe 13.4 x 6.2 x 2.5 amayintshi |
| Umkhiqizi | Romalon |
Iwaranti kanye Nokusekela
Romalon replacement parts are manufactured from durable, high-quality materials and undergo testing to meet OEM standards. If you encounter any issues with the product, please contact Romalon customer support through the platform where the purchase was made. Our professional after-sales team is available to provide assistance and satisfactory solutions.
For returns or replacements, please refer to the retailer's return policy, typically within 30 days of purchase.