IBO 750W

IBO 750W Submersible Sewage Pump with Grinder and Float - Instruction Manual

Model: 750W | Brand: IBO

1. Isingeniso

This manual provides essential information for the safe and efficient operation of your IBO 750W Submersible Sewage Pump. Please read these instructions carefully before installation, operation, or maintenance. Keep this manual for future reference.

The IBO 750W pump is designed for pumping dirty and clean water, including wastewater containing solids. Its integrated grinder system effectively shreds fibrous materials and solids, making it suitable for draining septic tanks, flooded rooms, and emptying swimming pools. The robust cast iron casing ensures durability for industrial-grade applications.

2. Ulwazi Lokuphepha

  • Ukuphepha Kagesi: Always disconnect the pump from the power supply before handling, cleaning, or performing any maintenance. Ensure the power supply matches the pump's specifications (230V). Do not operate the pump with damaged cables or plugs.
  • Ukucwiliswa emanzini: This pump is designed for submersible use only. Ensure it is fully submerged during operation to prevent overheating.
  • Uhlobo Lwamanzi: The pump is suitable for dirty water, wastewater, and clean water. Avoid pumping flammable, corrosive, or explosive liquids.
  • Izingane Nezilwane ezifuywayo: Keep children and pets away from the pump and the area of operation.
  • Ukubekwa Okuzinzile: Qinisekisa ukuthi iphampu ibekwe endaweni ezinzile, eqondile ukuze igweme ukugoba.
  • Izinto Zokuzivikela Zomuntu Siqu: Wear appropriate personal protective equipment (e.g., gloves, safety glasses) when handling the pump, especially when dealing with wastewater.

3. Umkhiqizo Uphelileview

The IBO 750W Submersible Sewage Pump features a powerful motor, an integrated grinder, and an automatic float switch for reliable operation. Its robust construction is designed for demanding applications.

IBO 750W Submersible Sewage Pump with Float Switch

Umfanekiso 1: IBO 750W Submersible Sewage Pump. This image shows the main pump unit, including the motor housing, discharge outlet, and the attached float switch for automatic operation.

Storz C Coupling for Pump Hose

Umfanekiso 2: Storz C Coupling. This image displays the quick-connect Storz C coupling, used for securely attaching the discharge hose to the pump's outlet.

Izingxenye:

  • Umzimba Wephampu: Durable cast iron construction.
  • Imoto: 750W (0.75 kW) for powerful operation.
  • Igrinder: Integrated system for shredding solids.
  • Ukuntanta Shintsha: Automatic on/off control based on water level.
  • Discharge Outlet: Compatible with 2", 1 1/2", and 1" hose connections.
  • Ikhebula Lamandla: Okokuxhunywa kukagesi.

4. Setha

  1. Ukukhulula: Khipha ngokucophelela iphampu nazo zonke izesekeli ephaketheni. Hlola ukuthi azinawo yini umonakalo.
  2. Ukuxhumana kweHose:
    • Attach the provided Storz C coupling to the pump's discharge outlet. Ensure a secure fit.
    • Connect the 20m hose (or your preferred hose) to the Storz C coupling. The pump also includes adaptors for 1 1/2" and 1" hoses if needed.
    • Route the discharge hose to the desired drainage point, ensuring it is free of kinks and obstructions.
  3. Ukubeka Iphampu:
    • Place the pump on a firm, level surface in the water to be drained. Ensure the intake is clear of debris.
    • The pump must be fully submerged during operation.
  4. Float Switch Adjustment:
    • The float switch controls the automatic on/off function. Adjust the cable length of the float switch to set the desired water levels for activation and deactivation.
    • Ensure the float switch can move freely and is not obstructed by walls or other objects.
  5. Uxhumano lukagesi:
    • Connect the pump's power plug to a grounded 230V electrical outlet.
    • Ensure the outlet is protected by a residual current device (RCD) for safety.

5. Iziqondiso Zokusebenza

  1. Ukuhlola kokuqala: Before starting, ensure all connections are secure and the pump is correctly positioned.
  2. Ukuqala i-Pump:
    • Once the pump is submerged and the power is connected, the float switch will activate the pump automatically when the water level rises to the preset 'on' level.
    • The pump will continue to operate until the water level drops to the preset 'off' level, at which point the float switch will deactivate it.
  3. Manual Operation (if applicable): If your model allows for manual override, ensure the float switch is secured in an 'on' position, but monitor the pump closely to prevent dry running.
  4. Ukuqapha: Periodically check the pump's operation, discharge flow, and the area for any unusual noises or vibrations.
  5. Ukumisa Iphampu: The pump will stop automatically when the water level drops. To manually stop the pump, disconnect it from the power supply.

6. Isondlo

Regular maintenance ensures the longevity and efficient performance of your pump. Always disconnect the pump from the power supply before any maintenance.

  • Ukuhlanza Iphampu: After use, especially with dirty water, rinse the pump thoroughly with clean water. Remove any debris or foreign objects from the intake screen, impeller, and grinder area.
  • Checking Cables and Connections: Regularly inspect the power cable, plug, and hose connections for wear, damage, or leaks. Replace damaged components immediately.
  • Ukuntanta Shintsha: Ensure the float switch is clean and moves freely. Debris can impede its operation.
  • Isitoreji: When not in use for extended periods, clean the pump, drain any remaining water, and store it in a dry, frost-free location.

7. Ukuxazulula izinkinga

InkingaImbangela EngenzekaIsixazululo
Ipompo ayiqali.Akukho ukunikezwa kwamandla.
Float switch not activated.
Motor overload/thermal protection activated.
Hlola ukuxhumeka kwamandla kanye ne-circuit breaker.
Ensure water level is high enough to activate float switch.
Disconnect power, allow pump to cool, then restart.
Iphampu iyasebenza kodwa akukho manzi akhishwayo noma ukugeleza kwayo kuphansi.I-hose ikhiyiwe noma ivinjiwe.
Intake screen blocked.
Impeller/grinder blocked.
Check and clear hose.
Disconnect power, clean intake screen.
Disconnect power, carefully clear impeller/grinder area.
Iphampu liyama kungalindelekile.Water level too low (float switch deactivated).
Ukugcwala okushisayo.
Ukuphazamiseka kwamandla.
Check water level and float switch position.
Allow pump to cool down.
Hlola ukunikezwa kwamandla.
Umsindo ongajwayelekile noma ukudlidliza.Debris in impeller/grinder.
Pump not stable.
Disconnect power, clear debris.
Ensure pump is on a stable, level surface.

8. Imininingwane

ImodeliIBO 750W Submersible Sewage Pump
Ukunikezwa kwamandla kagesi230 V / 3.8 A
Amandla Ezimoto0.75 kW (750 W)
UMax. Izinga Lokugeleza300 l/min (15,000 l/hour)
Ubukhulu. Khipha Ikhanda12 m
Usayizi Woxhumano2" (with adaptors for 1 1/2", 1")
IsisindoCishe. 20 kg
Ubukhulu (Ububanzi x Ubude)26 cm x 47 cm
OkubalulekileInsimbi
Included Hose Length20 m

9. Iwaranti kanye Nokusekela

For warranty information and technical support, please refer to your purchase documentation or contact the seller directly. Keep your proof of purchase for any warranty claims.

IBO is committed to providing quality products. If you encounter any issues not covered in this manual, please seek professional assistance or contact the authorized service center.

© 2026 IBO. All rights reserved.