BEMİS 48711-3 BEMİS

Bemis 4-Way Rubber Monophase Socket User Manual

Model: BK1-1402-3614

Brand: BEMİS

1. Isingeniso

This user manual provides essential information for the safe and effective use of the Bemis 4-Way Rubber Monophase Socket. Please read this manual thoroughly before installation and operation, and retain it for future reference. This product is designed for reliable power distribution in various environments, offering robust construction and IP44 protection.

2. Ulwazi Lokuphepha

Always adhere to local electrical codes and regulations when installing or using this product. Failure to do so may result in electric shock, fire, or serious injury.

  • Ingozi kagesi: Ensure power is disconnected before any installation, maintenance, or troubleshooting.
  • Abasebenzi Abafanelekile: Installation and wiring should only be performed by a qualified electrician.
  • Ukuvikelwa kokulayisha ngokweqile: Do not exceed the maximum rated current of 16 Amperes. Overloading can cause overheating and fire.
  • Izimo Zemvelo: This product has an IP44 rating, meaning it is protected against solid objects larger than 1mm and splashing water from any direction. Do not submerge the product in water or expose it to high-pressure water jets.
  • Ukuhlolwa Komonakalo: Before each use, inspect the socket for any signs of damage, cracks, or exposed wires. Do not use if damaged.
  • Isisekelo Esifanelekile: Ensure the product is properly grounded to prevent electric shock.

3. Umkhiqizo Uphelileview

The Bemis 4-Way Rubber Monophase Socket is a durable power distribution unit designed for demanding environments. It features four Schuko-type outlets, housed within a robust rubber casing, providing enhanced protection against impacts and environmental factors.

Bemis 4-Way Rubber Monophase Socket

Umfanekiso 3.1: Phezulu view of the Bemis 4-Way Rubber Monophase Socket, showing the four covered Schuko outlets and the robust rubber housing.

Izici Eziyinhloko:

  • Four Schuko Outlets: Provides multiple connection points for electrical devices.
  • Rubber Housing: Offers excellent durability and resistance to impact, chemicals, and harsh weather.
  • Ukuvikelwa kwe-IP44: Rated for protection against splashing water and solid objects, suitable for outdoor and industrial use.
  • Monophase Operation: Designed for single-phase electrical systems.
  • 16 AmpIsilinganiso: Supports devices requiring up to 16A current.
  • 200/250 Volt Compatibility: Operates within standard European voltage range.

4. Ukusetha nokufakwa

This product is designed for professional installation. Ensure all connections are secure and comply with relevant electrical standards.

  1. Ukulungiselela: Before beginning installation, ensure the main power supply to the circuit is turned off at the breaker or fuse box. Verify with a voltagumhloli.
  2. Ukukhweza (Uma uthanda): If mounting the socket, select a suitable, stable surface. Use appropriate fasteners (not included) through the designated mounting holes on the unit.
  3. Uxhumano Lwezintambo:
    • Open the wiring compartment of the socket.
    • Connect the incoming power cable (3 wires: Live, Neutral, Earth) to the corresponding terminals inside the socket. Ensure correct polarity and secure connections.
    • The product is designed for 3-wire connection (Live, Neutral, Earth) for 2P+E configuration.
    • Ensure all wire insulation is intact and no bare wires are exposed outside the terminals.
  4. I-Enclosure evikelekile: Close the wiring compartment securely, ensuring the rubber seals are properly seated to maintain the IP44 rating.
  5. Ukuhlola Kokugcina: Double-check all connections and ensure the unit is stable.
  6. Vula: Buyisela amandla kusekethe.

5. Iziqondiso Zokusebenza

Using the Bemis 4-Way Rubber Monophase Socket is straightforward once installed.

  1. Amadivayisi Axhumayo: Insert the plug of your electrical device into one of the four Schuko outlets. Ensure the plug is fully inserted.
  2. Protection Covers: The outlets are equipped with protective covers. Ensure these covers are closed when the outlet is not in use to maintain the IP44 rating and prevent ingress of dust or water.
  3. Ukuphatha Umthwalo: Do not connect devices that collectively exceed the total rated current of 16 Amperes for the entire socket.
  4. Inqamula Amadivayisi: To disconnect a device, firmly grasp the plug and pull it straight out of the socket. Do not pull by the cable.

6. Isondlo

Regular maintenance ensures the longevity and safe operation of your Bemis socket.

  • Ukuhlanza: Disconnect power before cleaning. Wipe the exterior with a damp cloth. Do not use abrasive cleaners or solvents. Ensure the unit is completely dry before reconnecting power.
  • Ukuhlola: Periodically inspect the cable, plug (if applicable), and the socket housing for any signs of wear, damage, or corrosion. Check that all screws are tight and seals are intact.
  • Isitoreji: If storing the unit for an extended period, ensure it is clean, dry, and stored in a cool, dry place away from direct sunlight and extreme temperatures.

7. Ukuxazulula izinkinga

Lesi sigaba sikhuluma ngezinkinga ezivamile ongahlangabezana nazo.

InkingaImbangela EngenzekaIsixazululo
No power from outlets.
  • Ukunikezwa kwamandla okuyinhloko kuvaliwe.
  • Ikhefu lesekethe likhubekile.
  • Uxhumo lwezintambo olungalungile.
  • Ukulayisha ngokweqile.
  • Hlola ukunikezwa kwamandla okuyinhloko.
  • Setha kabusha ikhefu lesifunda.
  • Inspect wiring (by qualified personnel).
  • Nciphisa umthwalo oxhunyiwe.
Socket feels warm.
  • Ukulayisha ngokweqile.
  • Ukuxhuma okuxekethile.
  • Nqamula amanye amadivayisi.
  • Have connections checked (by qualified personnel).
Water ingress despite IP44 rating.
  • Protective covers not closed.
  • Damaged housing/seals.
  • Exposed to high-pressure water.
  • Ensure covers are always closed when not in use.
  • Hlola umonakalo; buyisela uma kunesidingo.
  • Avoid high-pressure water exposure.

If the problem persists after attempting these solutions, contact a qualified electrician or Bemis customer support.

8. Imininingwane

Technical details for the Bemis 4-Way Rubber Monophase Socket.

Igama LomkhiqizoBemis 4-Way Rubber Monophase Socket
Inombolo YemodeliBK1-1402-3614 (Manufacturer's Model: 48711-3 BEMİS)
IbhrendiBEMİS
ASINB074GWM4VT
Voltage Isilinganiso200/250 V
Isilinganiso samanje16 Amperes
Isilinganiso SokuvikelaIP44
Inombolo Yezitolo

Umfanekiso 3.1: Phezulu view of the Bemis 4-Way Rubber Monophase Socket, showing the four covered Schuko outlets and the robust rubber housing.

Izici Eziyinhloko:

  • Four Schuko Outlets: Provides multiple connection points for electrical devices.
  • Rubber Housing: Offers excellent durability and resistance to impact, chemicals, and harsh weather.
  • Ukuvikelwa kwe-IP44: Rated for protection against splashing water and solid objects, suitable for outdoor and industrial use.
  • Monophase Operation: Designed for single-phase electrical systems.
  • 16 AmpIsilinganiso: Supports devices requiring up to 16A current.
  • 200/250 Volt Compatibility: Operates within standard European voltage range.

4. Ukusetha nokufakwa

This product is designed for professional installation. Ensure all connections are secure and comply with relevant electrical standards.

  1. Ukulungiselela: Before beginning installation, ensure the main power supply to the circuit is turned off at the breaker or fuse box. Verify with a voltagumhloli.
  2. Ukukhweza (Uma uthanda): If mounting the socket, select a suitable, stable surface. Use appropriate fasteners (not included) through the designated mounting holes on the unit.
  3. Uxhumano Lwezintambo:
    • Open the wiring compartment of the socket.
    • Connect the incoming power cable (3 wires: Live, Neutral, Earth) to the corresponding terminals inside the socket. Ensure correct polarity and secure connections.
    • The product is designed for 3-wire connection (Live, Neutral, Earth) for 2P+E configuration.
    • Ensure all wire insulation is intact and no bare wires are exposed outside the terminals.
  4. I-Enclosure evikelekile: Close the wiring compartment securely, ensuring the rubber seals are properly seated to maintain the IP44 rating.
  5. Ukuhlola Kokugcina: Double-check all connections and ensure the unit is stable.
  6. Vula: Buyisela amandla kusekethe.

5. Iziqondiso Zokusebenza

Using the Bemis 4-Way Rubber Monophase Socket is straightforward once installed.

  1. Amadivayisi Axhumayo: Insert the plug of your electrical device into one of the four Schuko outlets. Ensure the plug is fully inserted.
  2. Protection Covers: The outlets are equipped with protective covers. Ensure these covers are closed when the outlet is not in use to maintain the IP44 rating and prevent ingress of dust or water.
  3. Ukuphatha Umthwalo: Do not connect devices that collectively exceed the total rated current of 16 Amperes for the entire socket.
  4. Inqamula Amadivayisi: To disconnect a device, firmly grasp the plug and pull it straight out of the socket. Do not pull by the cable.

6. Isondlo

Regular maintenance ensures the longevity and safe operation of your Bemis socket.

  • Ukuhlanza: Disconnect power before cleaning. Wipe the exterior with a damp cloth. Do not use abrasive cleaners or solvents. Ensure the unit is completely dry before reconnecting power.
  • Ukuhlola: Periodically inspect the cable, plug (if applicable), and the socket housing for any signs of wear, damage, or corrosion. Check that all screws are tight and seals are intact.
  • Isitoreji: If storing the unit for an extended period, ensure it is clean, dry, and stored in a cool, dry place away from direct sunlight and extreme temperatures.

7. Ukuxazulula izinkinga

Lesi sigaba sikhuluma ngezinkinga ezivamile ongahlangabezana nazo.

InkingaImbangela EngenzekaIsixazululo
No power from outlets.
  • Ukunikezwa kwamandla okuyinhloko kuvaliwe.
  • Ikhefu lesekethe likhubekile.
  • Uxhumo lwezintambo olungalungile.
  • Ukulayisha ngokweqile.
  • Hlola ukunikezwa kwamandla okuyinhloko.
  • Setha kabusha ikhefu lesifunda.
  • Inspect wiring (by qualified personnel).
  • Nciphisa umthwalo oxhunyiwe.
Socket feels warm.
  • Ukulayisha ngokweqile.
  • Ukuxhuma okuxekethile.

Figure 8.1: EC Declaration of Conformity, indicating compliance with European directives for electrical products.

Bemis Modern Production Facilities and Laboratory Testing

Figure 8.2: Images showcasing Bemis's modern production facilities and dedicated laboratory for product testing, ensuring quality and reliability.

9. Iwaranti kanye Nokusekela

Bemis products are manufactured to high standards. For warranty information and technical support, please refer to the official Bemis webisayithi noma uthinte umsabalalisi wangakini. Gcina irisidi lakho lokuthenga njengobufakazi bokuthenga.

For general inquiries or support, you may visit the BEMİS brand page on Amazon or contact the seller directly via your Amazon order details.

© 2024 BEMİS. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.