1. Isingeniso
1.1 Umkhiqizo Uphelileview
The ASTRALPOOL Peristaltic Pump, Model 57178, is designed for precise fluid dosing applications. This pump features continuous flow regulation, adjustable from 0% to 100% of its maximum capacity. Flow adjustment is managed by varying the motor speed via a potentiometer conveniently located on the pump's front panel. It is capable of delivering up to 12 liters per hour at a maximum pressure of 1 bar.
1.2 Ulwazi Lokuphepha
Please read and understand all safety instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in personal injury or equipment damage.
- Always disconnect power before performing any installation or maintenance.
- Ensure the pump is installed in a dry, well-ventilated area, protected from direct sunlight and extreme temperatures.
- Qinisekisa ukuthi ukunikezwa kwamandla kagesi voltage matches the pump's requirements (230 Volts AC).
- Do not operate the pump with damaged cables or connections.
- Wear appropriate personal protective equipment (PPE) when handling chemicals or performing maintenance.
2. Ukusetha nokufakwa
2.1 Ukufaka Iphampu
Select a stable, vertical surface for mounting the pump. Ensure there is adequate space around the pump for ventilation and access for maintenance. Use appropriate fasteners to secure the pump firmly to the chosen surface.
2.2 Ukuxhunywa kukagesi
The pump requires a 230 Volts AC power supply. Connect the pump to a grounded electrical outlet. It is recommended to use a dedicated circuit with appropriate overcurrent protection. Consult a qualified electrician if you are unsure about electrical connections.
2.3 Fluid Connections
Identify the inlet and outlet ports on the pump. The inlet port typically draws fluid from the source, and the outlet port delivers the fluid. Connect appropriate tubing to these ports, ensuring all connections are secure and leak-free. Use tubing compatible with the fluid being pumped and capable of withstanding the operating pressure.

This image displays the Astralpool Peristaltic Pump, model 57178. The pump features a blue casing with a transparent front cover, allowing visibility of the internal peristaltic mechanism and tubing. At the bottom, two black connection ports are visible for fluid inlet and outlet.
3. Iziqondiso Zokusebenza
3.1 Ukuqala kokuqala
- Ensure all fluid connections are secure and the pump is properly mounted.
- Verify that the fluid source is available and the discharge line is correctly routed.
- Plug the pump into the power supply.
3.2 Flow Regulation
The pump's flow rate is adjusted using the potentiometer located on the front panel. Rotate the potentiometer clockwise to increase the flow rate and counter-clockwise to decrease it. The flow can be continuously regulated from 0% to 100% of the pump's maximum capacity (12 L/H).
4. Isondlo
4.1 Isondlo Esijwayelekile
- Regularly inspect the tubing for signs of wear, cracks, or blockages. Replace tubing as necessary.
- Check all connections for leaks and tighten if required.
- Keep the pump's exterior clean and free from dust and debris.
4.2 Ukuhlanza
To clean the pump, first disconnect it from the power supply. Wipe the exterior with a damp cloth. If the internal tubing requires cleaning, follow the manufacturer's guidelines for flushing the system with an appropriate cleaning solution, ensuring it is compatible with the pump materials and the fluids being handled.
5. Ukuxazulula izinkinga
| Inkinga | Imbangela Engenzeka | Isixazululo |
|---|---|---|
| Ipompo ayiqali | Akukho ukunikezwa kwamandla Ikhebuli yamandla eyonakele | Hlola ukuxhumeka kwamandla ne-outlet Inspect and replace cable if damaged |
| Akukho ukugeleza kwamanzi | Amashubhu akhiyiwe noma avinjiwe Isihlungi esingenayo sivalekile Potentiometer set to 0% | Inspect and clear tubing Hlanza noma shintsha isihlungi sokungenisa Adjust potentiometer to desired flow rate |
| Inconsistent flow | Umoya kulayini Worn tubing | Wopha umoya ohlelweni Replace peristaltic tubing |
| Ukuvuza kokuxhumeka | Ukuxhumana okuxekethile Damaged seals/tubing | Qinisa konke ukuxhumana Inspect and replace seals or tubing |
6. Imininingwane Yezobuchwepheshe
| Ukucaciswa | Inani |
|---|---|
| Ibhrendi | Astralpool |
| Inombolo Yemodeli | 57178 |
| Ubukhulu bomkhiqizo (L x W x H) | 23 x 11 x 13 cm |
| Isisindo | awu 900g |
| Voltage | 230 Volts (AC) |
| Isilinganiso sokugeleza | Up to 12 L/H (continuously adjustable) |
| Ingcindezi Ephezulu | 1 ibha |
| Ukutholakala Kwezingxenye Ezisele | Ulwazi alutholakali |