The Sicce Ultrazero Flat Sucking Pump is designed for efficient removal of water from various areas, including flooded cellars, garages, and other spaces where minimal residual water is desired. This submersible pump is capable of reducing water levels down to 2-3 mm.
Izici Eziyinhloko:
- Capable of pumping water down to 2 mm residual level.
- Fully submersible design.
- Handles dirt particles up to 3 mm in size.
- Equipped with a 10-meter power cable.
- Features a practical carry handle for easy transport.

Umdwebo 1: Ngaphezuluview of the Sicce Ultrazero Flat Sucking Pump.
2. Ulwazi Lokuphepha
Read all safety warnings and instructions before operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect the pump from the power supply before handling, cleaning, or performing any maintenance.
- Qinisekisa ukuthi unikezwa amandla ngevolthitage matches the pump's specifications (230 V/50 Hz).
- Do not operate the pump with a damaged power cord or plug. If damaged, it must be replaced by the manufacturer, service agent, or similarly qualified persons to avoid a hazard.
- Do not use the pump to handle flammable or explosive liquids.
- Gcina izingane kanye nabantu abangagunyaziwe kude nendawo yokusebenza.
- Ensure the pump is fully submerged during operation to prevent overheating.
- Avoid running the pump dry for extended periods.
- This pump is designed for water only. Do not use it for other liquids without consulting the manufacturer.
3. Ukusetha nokufakwa
Follow these steps to properly set up your Ultrazero pump:
- Khipha iphampu: Khipha ngokucophelela iphampu nazo zonke izesekeli ephaketheni. Hlola ukuthi azinawo yini umonakalo.
- Connect the Discharge Hose:
The pump features a 26.44 mm (3/4") AG pressure connection. Attach a suitable discharge hose (e.g., 20 mm (3/4") hose connection) to this outlet. Ensure the connection is secure to prevent leaks.

Figure 2: Close-up of the pump's discharge outlet and integrated carry handle.
- Misa Iphampu: Place the pump directly on the surface from which water needs to be removed. Ensure the pump is stable and upright. The flat base allows for efficient water removal down to minimal levels.
- Route the Discharge Hose: Direct the discharge hose to a suitable drainage area, ensuring the water will not flow back into the area being drained.
- Ukuxhuma kwamandla: Plug the 10-meter power cable into a grounded 230 V/50 Hz electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for added safety, especially in wet environments.

Figure 3: The flat base of the pump designed for low residual water levels.
4. Iziqondiso Zokusebenza
The Ultrazero pump is designed for simple operation:
- Gcwalisa Iphampu: Ensure the pump is fully submerged in the water you wish to remove. The pump requires water to cool its motor and operate correctly.
- Qala ukupompa: Once submerged and connected to power, the pump will begin operating automatically. It does not feature a float switch, so manual monitoring is required for optimal use.
- Gada Izinga Lamanzi: The pump will continue to operate until the water level reaches its minimum suction capability of 2-3 mm.
- Stop Pumping: To stop the pump, disconnect it from the power supply. It is recommended to disconnect the pump once the desired water level is reached or if the pump starts to run dry.

Figure 4: The Ultrazero pump effectively draining water from a small pool.

Figure 5: The pump in action on a flooded floor, demonstrating its low-level suction capability.

Figure 6: Illustration of the pump's ability to reduce water levels to approximately 2 mm.
5. Isondlo
Ukunakekelwa okuvamile kuqinisekisa ukuphila isikhathi eside nokusebenza kahle kwephampu yakho.
- Ukuhlanza: After each use, especially when pumping dirty water, rinse the pump thoroughly with clean water. This helps prevent sediment buildup.
- Hlola Imfucumfucu: Periodically check the pump's intake area for any debris (e.g., leaves, small stones) that might obstruct water flow. Remove any blockages carefully after disconnecting power.
- Ukuhlolwa Kwekhebula: Regularly inspect the power cable for cuts, abrasions, or other damage. Do not use the pump if the cable is damaged.
- Isitoreji: When not in use, store the pump in a clean, dry place, protected from frost.

Figure 7: The pump can also be used for transferring water for tasks like garden watering from a rain barrel.
6. Ukuxazulula izinkinga
If you encounter issues with your Ultrazero pump, refer to the following common problems and solutions:
| Inkinga | Imbangela Engenzeka | Isixazululo |
|---|---|---|
| Ipompo ayiqali. | Akukho ukunikezwa kwamandla. Ikhebuli yamandla ilimele. Motor overload protection activated. | Hlola ukuxhumeka kwamandla ne-outlet. Inspect cable for damage; replace if necessary (by qualified personnel). Disconnect power, allow motor to cool, then reconnect. |
| Iphampu liyagijima kodwa awekho amanzi aphumayo. | Intake blocked. Discharge hose kinked or blocked. Airlock in pump. | Disconnect power, clear intake. Check and clear discharge hose. Briefly lift and lower the pump while submerged to release trapped air. |
| Reduced pumping performance. | Partial blockage. Impeller worn. | Disconnect power, clean pump intake and impeller area. Contact customer support for service. |
| Iphampu liyama kungalindelekile. | Overheating due to low water level or blockage. Iphutha likagesi. | Disconnect power, check water level and clear blockages. Allow to cool. Uma inkinga iqhubeka, xhumana nokwesekwa kwamakhasimende. |
If the problem persists after attempting these solutions, please contact Sicce customer support.
7. Imininingwane Yezobuchwepheshe
Detailed specifications for the Sicce Ultrazero Flat Sucking Pump, Model 925607:
| Ukucaciswa | Inani |
|---|---|
| Ibhrendi | Sicce |
| Inombolo Yemodeli | 925607 |
| Max. Delivery Rate (Flow Rate) | 3000 l/h |
| Ubukhulu. Ubude bokulethwa | 3.1 m |
| Power Consumption (P1) | 80 W |
| I-Operating Voltage | 220-240V/50Hz |
| Conductor Length (Power Cable) | 10 m (three-core, indoor and outdoor use) |
| Uxhumano Lwengcindezi | 26.44 mm (3/4") AG |
| Hose Connection Diameter | 20 mm (3/4") |
| Max. Solids Size | 3 mm |
| Izinga Lamanzi Elisele | Down to 2-3 mm |
| Ubukhulu bomkhiqizo (Cishe) | 140 mm (Diameter) x 160 mm (Height) / 5.5" x 6.3" |
| Isisindo sento | 2.6 kg (5.72 lbs) |
| Shintsha Ukuntanta | Cha |
| Ukuvikelwa kokulayisha ngokweqile | No (Internal thermal protection may exist, but no external reset) |
| Umsuka | Kwenziwe e-Italy |

Figure 8: Technical drawing illustrating the pump's dimensions and 3/4" GAS connection.
8. Iwaranti kanye Nokusekela
For warranty information or technical support regarding your Sicce Ultrazero Flat Sucking Pump, please contact Sicce customer service. Keep your purchase receipt and model number (925607) handy when contacting support.
Umkhiqizi: Ebara
Ibhrendi: Sicce
For further assistance, visit the official Sicce webisayithi noma uthinte umsabalalisi wangakini.