1. Ulwazi Olubalulekile Lokuphepha
Please read and understand all instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage. Retain this manual for future reference.
- Ukuphepha Kagesi: Ensure power supply is disconnected before any installation or maintenance. All electrical wiring must be performed by a qualified electrician and comply with local codes and regulations.
- Ukuphepha Kokucindezela: This pump operates under pressure. Ensure all connections are secure and leak-free before operation.
- Ukuphepha Kwezinga Lokushisa: The pump handles fluids up to +130°C (266°F) and short-term up to +140°C (284°F). Exercise caution to avoid burns from hot surfaces or fluids.
- Ukufakwa: This pump is designed for hydronic circulating applications. Do not use for purposes other than its intended use.
2. Umkhiqizo Uphelileview
The Wilo Top S 2 x 40 is a wet rotor hydronics circulating pump designed for residential and light commercial applications. It features a robust construction from stainless steel, polypropylene, and metal-impregnated carbon, ensuring durability and efficient performance. This model includes a two-speed motor for manual capacity adjustment.

Umfanekiso 1: Wilo Top S 2 x 40 Wet Rotor Hydronics Circulating Pump. This image displays the main unit of the circulating pump, highlighting its compact design and connection points.
Izici Eziyinhloko:
- Wet rotor, seal-less design for quiet and maintenance-free operation.
- Two pre-selectable speed stages for manual capacity adjustment.
- Constructed from stainless steel, polypropylene, and metal-impregnated carbon for durability.
- Cataphoretic coated pump housing for enhanced corrosion resistance.
- Permitted temperature range: -20°C to +130°C (short-term to +140°C).
- Pump communication based on simple plug technology for reliable retrofitting.
3. Ukufakwa kanye nokusetha
Proper installation is crucial for the safe and efficient operation of your Wilo circulating pump. It is highly recommended that installation be performed by a qualified professional.
3.1 Ukuhlolwa Kwangaphambi Kokufakwa:
- Qinisekisa ukuthi ivolumu yephamputage (115-Volt) matches your electrical supply.
- Ensure the installation location is suitable, providing adequate space for maintenance and ventilation.
- Confirm that the system piping is clean and free of debris.
3.2 Mechanical Installation:
- The pump requires 4 Bolt 2-Inch HV flanges (not included) for connection to the piping system. Ensure these flanges are correctly sized and installed.
- Install the pump in a horizontal position with the motor shaft horizontal to prevent air pockets and ensure proper lubrication.
- Use appropriate gaskets and tighten flange bolts evenly to prevent leaks.
- Support the pump and piping adequately to prevent strain on the connections.
3.3 Ukuxhumana kukagesi:
- All electrical work must comply with national and local electrical codes.
- Connect the pump to a dedicated, properly fused electrical circuit.
- Qinisekisa ukuthi ipompo iphansi ngendlela efanele.
- Refer to the wiring diagram provided with the pump for specific connection details.
4. Iziqondiso Zokusebenza
Once installed and electrically connected, the Wilo Top S 2 x 40 pump is ready for operation.
4.1 Ukuqala kokuqala:
- Before starting, ensure the system is filled with fluid and properly vented to remove any air.
- Open all necessary valves in the system.
- Apply power to the pump. The pump should start circulating fluid.
- Hlola noma imiphi imisindo noma ukudlidliza okungajwayelekile.
4.2 Speed Adjustment:
The Wilo Top S 2 x 40 features two pre-selectable speed stages. These can be adjusted manually to optimize flow rate and energy consumption for your specific hydronic system requirements. Consult your system design for the appropriate speed setting.
4.3 Normal Operation:
The pump is designed for continuous operation within its specified temperature range of -20°C to +130°C. Monitor the system for consistent performance and absence of leaks.
5. Isondlo
The Wilo Top S 2 x 40 wet rotor design is largely maintenance-free. However, periodic checks are recommended to ensure optimal performance and longevity.
5.1 Ukuhlolwa Okuvamile:
- Ukuhlola Okubonakalayo: Periodically inspect the pump for any signs of leaks, corrosion, or damage to the housing or electrical connections.
- Umsindo nokudlidliza: Listen for any unusual noises or excessive vibrations, which could indicate a problem.
- Ingcindezi Yesistimu: Ensure the system pressure remains within the recommended operating range.
5.2 Ukuhlanza:
Keep the exterior of the pump clean and free of dust and debris to ensure proper heat dissipation.
5.3 Winterization:
If the pump is installed in an unheated area subject to freezing temperatures, ensure the system is properly drained or protected with antifreeze to prevent damage.
6. Ukuxazulula izinkinga
This section provides solutions to common issues you might encounter with your Wilo circulating pump. For complex problems, contact a qualified technician.
| Inkinga | Imbangela Engenzeka | Isixazululo |
|---|---|---|
| Ipompo ayiqali | Akukho ukunikezwa kwamandla Kushaqwe imoto Izintambo ezingalungile | Hlola i-circuit breaker/fuse Xhumana nochwepheshe wesevisi Verify wiring with diagram |
| Izinga lokugeleza eliphansi | Umoya kusistimu Partially closed valves Clogged impeller/piping Ukulungiselelwa kwesivinini okungalungile | Vent uhlelo Open all valves Inspect and clean system Adjust speed setting |
| Umsindo omkhulu/ukudlidliza | Umoya kusistimu Ukukhweza okuxekethile Into yangaphandle epompo | Vent system thoroughly Qinisa amabhawodi afakayo Xhumana nochwepheshe wesevisi |
| Ukuvuza kokuxhumeka | Loose flange bolts I-gasket eyonakele | Tighten bolts evenly Faka esikhundleni i-gasket |
7. Imininingwane
Detailed technical specifications for the Wilo Top S 2 x 40 Circulating Pump, Model 2067579.
| Isibaluli | Inani |
|---|---|
| Inombolo Yemodeli | 2067579 |
| Umkhiqizi | Wilo |
| Isisindo sento | 45.8 amakhilogremu |
| Ubukhulu bephakheji | 18.9 x 16 x 13 amayintshi |
| Okubalulekile | I-Polypropylene, Insimbi Engagqwali |
| Umthombo wamandla | AC/DC |
| Voltage | 115 volts |
| Inani Lephakheji Yento | 1 |
| Permitted Temperature Range | -20°C to +130°C (short-term to +140°C) |
| Shutoff Head | 40 izinyawo |
| Flange Requirement | Uses 4 Bolt 2-Inch HV flanges (not included) |
8. Iwaranti kanye Nokusekela
8.1 Ulwazi Lwesiqinisekiso:
Wilo Commercial Building Services products, including this circulating pump, come with a Iwaranti ekhawulelwe yeminyaka engu-2 kusukela ngosuku lokuthenga. Lesi siqinisekiso simboza amaphutha ezintweni zokwakha kanye nobuciko ngaphansi kokusetshenziswa okuvamile kanye nesevisi. Sicela ugcine ubufakazi bakho bokuthenga ukuze uthole izimangalo zesiqinisekiso.
8.2 Ukwesekwa Kwamakhasimende:
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Wilo customer service. Have your pump model number (2067579) and date of purchase ready when contacting support.
You can find contact information for Wilo customer service on their official webnoma ngomsabalalisi wendawo yakho.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.