Isingeniso
This manual provides detailed instructions for the installation, operation, and maintenance of the Aiphone LE-D Surface Audio Door Station. The LE-D is designed to work with Aiphone LEF and LEM Series master intercoms (sold separately) to facilitate remote audio communication with visitors at an entry point. Please read this manual thoroughly before installation and use to ensure proper function and safety.
Ulwazi Lokuphepha
- Ensure all power is disconnected before attempting installation or maintenance.
- Ukufakwa kufanele kwenziwe ngabasebenzi abaqeqeshiwe ngokuhambisana namakhodi kagesi wendawo.
- Do not expose the unit to excessive moisture or extreme temperatures beyond its specified operating range.
- Use only specified mounting hardware and accessories.
Okuqukethwe Kwephakheji
Qinisekisa ukuthi zonke izinto zikhona ngaphambi kokuqala ukufakwa:
- Aiphone LE-D Door Intercom Unit
- I-Mounting Hardware (izikulufu, amahange)
Ukusetha nokufaka
1. Indawo yokukhweza
Select a suitable outdoor location near the entry point, ensuring it is within reach of the wiring for the master intercom. The unit is weather-resistant, but positioning it under an overhang can provide additional protection from direct heavy rain.
2. Surface Mounting
- Carefully remove the front cover of the LE-D unit to expose the mounting holes and wiring terminals.
- Position the backplate of the LE-D unit against the wall or single-gang box where it will be mounted. Mark the positions for the mounting screws.
- Drill pilot holes if necessary, then secure the backplate to the surface using the provided mounting hardware. Ensure the unit is level.
3. Izintambo zokuxhuma
Refer to the wiring diagram below and the instructions provided with your Aiphone LEF or LEM Series master intercom for specific wiring details. The LE-D unit typically requires two wires for audio communication and power from the master intercom.

Isithombe: Emuva view of the Aiphone LE-D Surface Audio Door Station. This image displays the internal components, including the wiring terminals (three screw terminals visible at the bottom right), the model number label (LE-D, Lot No. HG54144 R, IP43 Inspected, Aiphone Co., Ltd., CE mark), and mounting points. This view is crucial for understanding how to connect the unit.
- Connect the two wires from the master intercom to the designated terminals on the LE-D unit. Polarity may be important; consult your master intercom manual.
- Qinisekisa ukuthi konke ukuxhuma kuphephile futhi kuvaliwe ukuvimbela amasekhethi amafushane.
4. Umhlangano Wokugcina
Once wiring is complete, carefully reattach the front cover of the LE-D unit. Ensure it snaps or screws into place securely to maintain its weather resistance.
Imiyalelo yokusebenza
Ivula Ucingo
When a visitor presses the call button on the LE-D door station, a chime will sound on the connected Aiphone LEF or LEM Series master intercom. This indicates a visitor is at the door.
Ukuxhumana Okubili
To communicate with the visitor, the occupant must activate the talk function on the master intercom. Audio communication is then established between the door station and the master intercom.
Isondlo
- Ukuhlanza: Periodically wipe the exterior of the door station with a soft, damp indwangu. Ungasebenzisi izinto zokuhlanza abrasive noma izincibilikisi.
- Ukuhlola: Regularly check the unit for any signs of damage or loose connections. Ensure the front cover is securely fastened.
- Ukuvikelwa Kwemvelo: While weather-resistant, extreme conditions can affect performance. Ensure proper drainage around the unit if installed in an area prone to standing water.
Ukuxazulula inkinga
| Inkinga | Imbangela Engenzeka | Isixazululo |
|---|---|---|
| No chime at master intercom when call button is pressed. | Loose or incorrect wiring; faulty master intercom; faulty door station button. | Check all wiring connections at both the door station and master intercom. Ensure master intercom is powered on and functioning. Test the call button for proper mechanical action. |
| Akukho msindo noma ikhwalithi yomsindo ephansi. | Loose or incorrect wiring; microphone/speaker obstruction; faulty components. | Verify wiring connections. Ensure microphone and speaker grilles are clear of debris. Test with another master intercom if possible. |
| Door station appears damaged. | Physical impact; environmental exposure. | Inspect for cracks or breaks. If functionality is affected, replacement may be necessary. |
If troubleshooting steps do not resolve the issue, contact Aiphone customer support or a qualified technician.
Imininingwane
- Imodeli: I-LE-D
- Uhlobo: Surface-mount audio door station
- Ukuhambisana: Aiphone LEF and LEM Series master intercoms (sold separately)
- Impahla Yezindlu: Weather-resistant black plastic
- Ukukhweza: Surface mounts to a single-gang box
- Ubukhulu (H x W x D): 120 x 88 x 29 mm (4-3/4 x 3-7/16 x 1-1/8 inches)
- Product Dimensions (approximate): 1.65 x 4.65 x 5.43 amayintshi
- Isisindo Sento: 7.4 amakhilogremu
- Isilinganiso Sendawo: IP43 (as indicated on unit label)
Iwaranti kanye Nokusekela